Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Radiol Bras ; 53(5): 337-344, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33071378

RESUMO

Soft-tissue calcifications are extremely common. Because the imaging findings are nonspecific, soft-tissue calcifications are often problematic for radiologists, sometimes prompting unnecessary interventions. In addition, the nomenclature is quite confusing. Classically, soft-tissue calcifications are divided into four categories, by mechanism of formation-dystrophic, iatrogenic, metastatic, and idiopathic-depending on the clinical and biochemical correlation. However, it is also possible to classify such calcifications by compartment, and that classification can be quite useful in the radiological diagnostic assessment. In this article, we illustrate the main causes of soft-tissue calcifications, organizing them according to their anatomical and pathophysiological aspects, thus narrowing the differential diagnosis.


Calcificações de partes moles são achados extremamente comuns e inespecíficos nos exames de imagem e, por isso, frequentemente são fonte de confusão por parte dos radiologistas, desencadeando, por vezes, intervenções desnecessárias. Além disso, a nomenclatura atribuída é muito confusa. Classicamente, dividem-se as calcificações de partes moles, conforme seu mecanismo de formação, em calcificações distróficas, iatrogênicas, metastáticas e idiopáticas, dependendo de correlação clinicolaboratorial, porém, também é possível uma classificação compartimental das calcificações, que pode ser muito útil na propedêutica radiológica. Neste trabalho, ilustramos didaticamente as principais causas de calcificações de partes moles organizando-as de acordo com aspectos anatômicos e fisiopatológicos, estreitando os diagnósticos diferenciais.

2.
Radiol Bras ; 47(2): 74-8, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25741052

RESUMO

OBJECTIVE: Undertaking of a complete audit of the service of mammography, as recommended by BI-RADS(®), in a private reference institution for breast cancer diagnosis in the city of São Paulo, SP, Brazil, and comparison of results with those recommended by the literature. MATERIALS AND METHODS: Retrospective, analytical and cross-sectional study including 8,000 patients submitted to mammography in the period between April 2010 and March 2011, whose results were subjected to an internal audit. The patients were followed-up until December 2012. RESULTS: The radiological classification of 7,249 screening mammograms, according to BI-RADS, was the following: category 0 (1.43%), 1 (7.82%), 2 (80.76%), 3 (8.35%), 4 (1.46%), 5 (0.15%) and 6 (0.03%). The breast cancer detection ratio was 4.8 cases per 1,000 mammograms. Ductal carcinoma in situ was found in 22.8% of cases. Positive predictive values for categories 3, 4 and 5 were 1.3%, 41.3% and 100%, respectively. In the present study, the sensitivity of the method was 97.1% and specificity, 97.4%. CONCLUSION: The complete internal audit of a service of mammography is essential to evaluate the quality of such service, which reflects on an early breast cancer detection and reduction of mortality rates.


OBJETIVO: Realização de auditoria completa do serviço de mamografia de uma instituição privada, conforme preconizado pelo BI-RADS®, e comparação dos resultados obtidos com os recomendados pela literatura em serviço de referência em diagnóstico de câncer mamário na cidade de São Paulo. MATERIAIS E MÉTODOS: Estudo retrospectivo, analítico e transversal contendo casuística de 8.000 pacientes que realizaram mamografias no período de abril de 2010 a março de 2011, submetidas à auditoria, com base no resultado de sua mamografia. Houve seguimento dessas pacientes até dezembro de 2012. RESULTADOS: De acordo com a categorização BI-RADS, a classificação radiológica das 7.249 mamografias de rastreamento, em relação ao número de casos, foi a seguinte: categorias 0 (1,43%), 1 (7,82%), 2 (80,76%), 3 (8,35%), 4 (1,46%), 5 (0,15%) e 6 (0,03%). Verificou-se taxa de detecção para câncer mamário de 4,8 casos para cada 1.000 exames realizados. O total de carcinoma ductal in situ foi 22,8%. Foram encontrados valores preditivos positivos para as categorias 3, 4 e 5 de 1,3%, 41,3% e 100%, respectivamente. A sensibilidade do método aferida foi 97,1% e a especificidade, 97,4%. CONCLUSÃO: A auditoria interna completa do serviço de mamografia retrata a qualidade do serviço, e com isso contribui para a detecção precoce e diminuição da mortalidade relacionada ao câncer mamário.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA