Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Pacing Clin Electrophysiol ; 42(2): 120-129, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30536931

RESUMO

BACKGROUND: Patient satisfaction with remote patient monitoring (RPM) of implantable cardioverter defibrillators (ICDs) seems to be high, yet knowledge on long-term patient experiences is limited. The European REMOTE-CIED study explored patients' experiences with RPM, examined patient's preferences for ICD follow-up, and identified determinants of patient's preferences in the first 2 years postimplantation. METHODS: European heart failure patients (N = 300; median age = 66 years [interquartile range (IQR) = 59-73], and 22% female) with a first-time ICD received a Boston Scientific LATITUDE RPM system (Marlborough, MA, USA) and had scheduled in-clinic follow-ups once a year. Patients completed questionnaires at 1-2 weeks and also at 3, 6, 12, and 24 months postimplantation and clinical data were obtained from their medical records. Patient evaluation data were analyzed descriptively, and Student's t-tests/Man-Whitney U tests or Chi-square tests/Fisher's exact tests were performed to examine determinants of patient preferences. RESULTS: At 2 years postimplantation, the median patient satisfaction score with the RPM system was 9 out of 10 (IQR = 8-10), despite 53% of the patients experiencing issues (eg, failure to transmit data). Of the 221 patients who reported their follow-up preferences, 43% preferred RPM and 19% preferred in-clinic follow-up. Patients with a preference for RPM were more likely to be higher educated (P = 0.04), employed (P = 0.04), and equipped with a new LATITUDE model (P = 0.04), but less likely to suffer from chronic obstructive pulmonary disease (P = 0.009). CONCLUSION: In general, patients were highly satisfied with RPM, but a subgroup preferred in-clinic follow-up. Therefore, physicians should include patients' concerns and preferences in the decision-making process, to tailor device follow-up to individual patients' needs and preferences.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca/terapia , Monitorização Fisiológica/métodos , Satisfação do Paciente , Telemedicina , Idoso , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Preferência do Paciente , Autorrelato , Inquéritos e Questionários
2.
Am J Cardiol ; 101(7): 1023-9, 2008 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-18359325

RESUMO

Objectives of this study were to perform a prospective head-to-head comparison between multi-slice computed tomography (MSCT) venography and invasive venography in cardiac resynchronization therapy (CRT) candidates as well as to evaluate the relation between left ventricular (LV) lead position and effect on LV dyssynchrony and immediate response to CRT. Twenty-one consecutive heart failure patients scheduled for CRT implantation were prospectively enrolled to undergo 64-slice MSCT to visualize the venous system, invasive venography during device implantation, and tri-plane tissue synchronization imaging (TSI) before and after implantation. Excellent agreement between MSCT and invasive venography was noted. No significant differences were observed between both techniques regarding vessel diameters. In 12 patients, a match was observed between the area of latest mechanical activation (on TSI) and LV lead position. These patients showed a significant decrease in LV dyssynchrony (43 +/- 7 ms to 11 +/- 9 ms, p <0.0001) with acute reduction in LV end-systolic volume (188 +/- 54 ml to 162 +/- 48 ml, p <0.01) and improvement in LV ejection fraction (22% +/- 9% to 34% +/- 9%, p <0.01). Patients with a mismatch between area of latest activation and LV lead position remained dyssynchronous without improvement in LV function. In conclusion, visualization of major tributaries of the coronary sinus was comparable between invasive venography and MSCT venography. Optimal LV lead positioning in a vein draining the area of latest mechanical activation (determined from tri-plane TSI) resulted in acute improvement of LV dyssynchrony and systolic function after CRT implantation.


Assuntos
Estimulação Cardíaca Artificial , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Disfunção Ventricular Esquerda/diagnóstico , Idoso , Vasos Coronários , Ecocardiografia , Feminino , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Flebografia , Sístole , Tomografia Computadorizada por Raios X , Função Ventricular Esquerda
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA