RESUMO
Background A curve-shaped compression paddle could reduce the pain experienced by some women at breast cancer screening. Purpose To compare curved and standard compression systems in terms of pain experience and image quality in mammography screening. Materials and Methods In this randomized controlled trial conducted between October 2021 and February 2022, participants screened at three screening sites in the Netherlands were randomized to either a curved-paddle or sham-paddle group. The sham paddle was a standard paddle that was presented as a new paddle. At a standard screening examination, one additional image was acquired with a curved or sham paddle. Pain was measured on a numerical rating scale (range, 0-10). Participants provided a pain score after compression with the standard and test paddles, resulting in two scores per participant. Differences in pain scores were compared between groups using analysis of covariance, adjusting for pain score after standard-paddle compression. Two radiographers and two radiologists performed unblinded paired comparisons of curved-paddle vs standard-paddle images, using standard image quality criteria (radiographers evaluated 1246 image pairs using 12 criteria; radiologists evaluated 320 image pairs using six criteria). The one-sample Wilcoxon signed-rank test was used to determine if there was a significant preference for either paddle. Results In total, 2499 female participants (mean age, 61.6 years ± 7.1 [SD]) were studied; 1250 in the curved-paddle group and 1249 in the sham-paddle group. The mean pain score decreased by an additional 0.19 points in the curved-paddle group compared with the sham-paddle group (95% CI: 0.09, 0.28; P < .001). In terms of image quality, the observers showed no preference or a preference for the standard paddle. Decreased image contrast (range Bonferroni-corrected P values: P < .001 to P > .99) and visibility of structures were the main concerns for curved-paddle images. Conclusion The use of the curved paddle resulted in a minimal pain reduction during mammography breast compression but image quality was reduced. © RSNA, 2024 Supplemental material is available for this article.
Assuntos
Neoplasias da Mama , Mamografia , Humanos , Feminino , Mamografia/métodos , Neoplasias da Mama/diagnóstico por imagem , Pessoa de Meia-Idade , Idoso , Medição da Dor , Detecção Precoce de Câncer/métodos , Países Baixos , Dor/etiologia , Dor/prevenção & controle , Mama/diagnóstico por imagemRESUMO
BACKGROUND: During healthcare guideline development, panel members often have implicit, different definitions of health outcomes that can lead to misunderstandings about how important these outcomes are and how to balance benefits and harms. McMaster GRADE Centre researchers developed 'health outcome descriptors' for standardizing descriptions of health outcomes and overcoming these problems to support the European Commission Initiative on Breast Cancer (ECIBC) Guideline Development Group (GDG). We aimed to determine which aspects of the development, content, and use of health outcome descriptors were valuable to guideline developers. METHODS: We developed 24 health outcome descriptors related to breast cancer screening and diagnosis for the European Commission Breast Guideline Development Group (GDG). Eighteen GDG members provided feedback in written format or in interviews. We then evaluated the process and conducted two health utility rating surveys. RESULTS: Feedback from GDG members revealed that health outcome descriptors are probably useful for developing recommendations and improving transparency of guideline methods. Time commitment, methodology training, and need for multidisciplinary expertise throughout development were considered important determinants of the process. Comparison of the two health utility surveys showed a decrease in standard deviation in the second survey across 21 (88%) of the outcomes. CONCLUSIONS: Health outcome descriptors are feasible and should be developed prior to the outcome prioritization step in the guideline development process. Guideline developers should involve a subgroup of multidisciplinary experts in all stages of development and ensure all guideline panel members are trained in guideline methodology that includes understanding the importance of defining and understanding the outcomes of interest.
Assuntos
Medicina Baseada em Evidências/métodos , Avaliação de Resultados em Cuidados de Saúde/métodos , Guias de Prática Clínica como Assunto , Indicadores Básicos de Saúde , Humanos , Qualidade de VidaRESUMO
PURPOSE: Our purpose was to compare mammographic positioning quality of new (NR) versus experienced screening radiographers (ER) in the Netherlands. METHODS AND MATERIALS: Before starting to work in breast screening, NR must complete an education programme including a theoretical course (four days), practical training (six weeks), and a portfolio-review of 50 mammographic screening examinations performed by the radiographer. Furthermore, Dutch screening has an extensive system of quality assurance, including an audit-review of positioning quality of mammograms by ER. We analysed 13,520 portfolio views (NR) and 14,896 audit views (ER) based on pre-specified criteria, e.g., depiction of inframammary angle. RESULTS: Overall positioning was more adequate for NR than ER (CC views: 97% versus 86%, p = 0.00; MLO views: 92% versus 84%, p = 0.00). NR scored better for most of the CC-criteria and showed, for instance, less folds (inadequate: 10% versus 16%, p = 0.00). In contrast, NR encountered more difficulties for MLO views in, for example, depiction of infra-mammary angle (inadequate: 38% versus 34%, p = 0.00). Overall, mammograms from NR were more often considered adequate, because of less severe errors. CONCLUSION: NR perform better than ER in overall positioning technique. These results stress the need for continuous monitoring and training in breast screening programmes to keep positioning skills up to date. KEY POINTS: ⢠We evaluated positioning quality of new and experienced Dutch screening radiographers. ⢠New radiographers outperform their experienced colleagues in mammographic positioning quality. ⢠New radiographers make less severe errors compared to experienced colleagues. ⢠There is a need for a continuous individual monitoring and feedback system.
Assuntos
Competência Clínica/normas , Mamografia/normas , Posicionamento do Paciente/normas , Radiologia/normas , Neoplasias da Mama/diagnóstico por imagem , Estudos Transversais , Detecção Precoce de Câncer/normas , Feminino , Humanos , Mamografia/métodos , Programas de Rastreamento/normas , Pessoa de Meia-Idade , Países BaixosRESUMO
PURPOSE: To compare pain, projected breast area, radiation dose and image quality between flexible (FP) and rigid (RP) breast compression paddles. METHODS: The study was conducted in a Dutch mammographic screening unit (288 women). To compare both paddles one additional image with RP was made, consisting of either a mediolateral-oblique (MLO) or craniocaudal-view (CC). Pain experience was scored using the Numeric Rating Scale (NRS). Projected breast area was estimated using computer software. Radiation dose was estimated using the model by Dance. Image quality was reviewed by three radiologists and three radiographers. RESULTS: There was no difference in pain experience between both paddles (mean difference NRS: 0.08 ± 0.08, p = 0.32). Mean radiation dose was 4.5 % lower with FP (0.09 ± 0.01 p = 0.00). On MLO-images, the projected breast area was 0.79 % larger with FP. Paired evaluation of image quality indicated that FP removed fibroglandular tissue from the image area and reduced contrast in the clinically relevant retroglandular area at chest wall side. CONCLUSIONS: Although FP performed slightly better in the projected breast area, it moved breast tissue from the image area at chest wall side. RP showed better contrast, especially in the retroglandular area. We therefore recommend the use of RP for standard MLO and CC views.
Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mamografia/instrumentação , Idoso , Mama/patologia , Neoplasias da Mama/patologia , Feminino , Humanos , Mamografia/métodos , Mamografia/normas , Pessoa de Meia-Idade , Variações Dependentes do Observador , Dor/etiologia , Dor/prevenção & controle , Doses de Radiação , Radiologia/estatística & dados numéricos , SoftwareRESUMO
OBJECTIVE: To assess the image quality of mammograms in females with an implanted medical device (IMD), to evaluate pain and anxiety during mammography in these females and to investigate the experience of radiographers. METHODS: Image quality was evaluated by two radiographers and one radiologist in the images of females with an IMD participating in the Dutch screening programme (clients). Pain and anxiety were scored using a Numeric Rating Scale in both clients visiting a screening organization and patients from the Isala Hospital, Zwolle. Experience of screening radiographers was collected with a questionnaire. RESULTS: Images of the breast with IMD showed reduced contrast in craniocaudal (CC) and mediolateral-oblique (MLO) views [by both the radiographers and radiologist (range: 11-29%)], less projected breast tissue [only radiographers; CC lateral side: 25.5%, 95% confidence interval (CI): 18.7-32.2] and reduced projection of the pectoral muscle (only radiographers; MLO width pectoral muscle: 31.5%, 95% CI: 24.4-38.7). Clients experienced more pain and anxiety during mammography in the breast with IMD compared to the breast without IMD in the breast (pain difference CC: 0.48 ± 0.16, p = 0.003; pain difference MLO: 0.46 ± 0.16, p = 0.004; anxiety difference 1.30 ± 0.22; p < 0.001). Patients experienced more pain (1.05 ± 0.12; p < 0.001) and anxiety (1.22 ± 0.15; p < 0.001) after placement of IMD. Radiographers are more cautious, more anxious and use less compression during mammography of breasts with IMD. CONCLUSION: Image quality in a breast with an IMD could be improved by projecting more breast tissue on the mammogram, thereby including (part of) the IMD between the paddles, if required. In addition, radiographers should pay sufficient attention to reducing discomfort both before and during the screening examination. ADVANCES IN KNOWLEDGE: Little is known about the quality of mammography in females with an IMD or how these females and radiographers experience the screening examination. The results of our study showed that having an IMD could result in a suboptimal mammogram and increased discomfort.