Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
J Heart Valve Dis ; 23(3): 289-91, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-25296450

RESUMO

The case is presented of a 75-year-old man referred for transcatheter aortic valve implantation. During the procedure the prosthetic aortic valve became dislocated into the left ventricle shortly after expansion. The subsequent steps taken to reposition the valve using only materials at hand are described.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Cateterismo Cardíaco , Migração de Corpo Estranho/etiologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Idoso , Estenose da Valva Aórtica/fisiopatologia , Hemodinâmica , Humanos , Masculino
2.
EuroIntervention ; 12(4): 499-507, 2016 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-27436602

RESUMO

AIMS: Our aim was to determine whether use of the filter-based Sentinel™ Cerebral Protection System (CPS) during transcatheter aortic valve implantation (TAVI) can affect the early incidence of new brain lesions, as assessed by diffusion-weighted magnetic resonance imaging (DW-MRI), and neurocognitive performance. METHODS AND RESULTS: From January 2013 to July 2015, 65 patients were randomised 1:1 to transfemoral TAVI with or without the Sentinel CPS. Patients underwent DW-MRI and extensive neurological examination, including neurocognitive testing one day before and five to seven days after TAVI. Follow-up DW-MRI and neurocognitive testing was completed in 57% and 80%, respectively. New brain lesions were found in 78% of patients with follow-up MRI. Patients with the Sentinel CPS had numerically fewer new lesions and a smaller total lesion volume (95 mm3 [IQR 10-257] vs. 197 mm3 [95-525]). Overall, 27% of Sentinel CPS patients and 13% of control patients had no new lesions. Ten or more new brain lesions were found only in the control cohort (in 20% vs. 0% in the Sentinel CPS cohort, p=0.03). Neurocognitive deterioration was present in 4% of patients with Sentinel CPS vs. 27% of patients without (p=0.017). The filters captured debris in all patients with Sentinel CPS protection. CONCLUSIONS: Filter-based embolic protection captures debris en route to the brain in all patients undergoing TAVI. This study suggests that its use can lead to fewer and overall smaller new brain lesions, as assessed by MRI, and preservation of neurocognitive performance early after TAVI. CLINICAL TRIAL REGISTRATION: Dutch trial register-ID: NTR4236. URL http://www.trialregister.nl/trialreg/admin/rctsearch.asp?Term=mistral.


Assuntos
Estenose da Valva Aórtica/cirurgia , Isquemia Encefálica/terapia , Dispositivos de Proteção Embólica , Embolia Intracraniana/prevenção & controle , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/métodos , Imagem de Difusão por Ressonância Magnética/métodos , Feminino , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Testes Neuropsicológicos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA