RESUMO
Trans-chalcone (TC) is a flavonoid precursor characterized by a wide spectrum of action, with anti-inflammatory and antioxidant effects. However, no validated methods are available in official compendia for the analysis of this substance. Thus, the aim of this work was to develop and validate a simple, fast, and reproducible spectrophotometric method for the analysis of TC in raw material, and in topical pharmaceutical formulation containing TC. The established conditions were: methanol as extracting solvent, and detection wavelength of 309 nm by UV spectrophotometer. All tests followed the rules of Resolution RDC 166, 2017. The proposed method was selective. Linearity was demonstrated in the concentration range of 1 to 8 µg/mL (r = 0.999). Repeatability and intermediate precision were confirmed by low relative standard deviation values of 1.53% and 2.70% for TC, and of 1.73% and 2.91% for formulation containing TC. Accuracy, evaluated through recovery test, was adequate, with minimum of 98.24% and maximum of 100.23% of recovery. It was observed that the small deliberate modifications done did not interfere with the results, demonstrating the method is robust. The results showed that the method was considered suitable for the intended purpose, inexpensive, easy to apply, selective, linear, precise, accurate, and robust for the determination TC, and pharmaceutical formulation containing TC. Thus, the method developed satisfies the need for an analytical method for the determination of TC, and topical formulation containing TC, being effective, innovative and able to aid in the development of the pharmaceutical field.
Trans-chalcona (TC) é um precursor de flavonoides caracterizado por um amplo espectro de ação, como efeitos anti-inflamatórios e antioxidantes. No entanto, não há método validado disponível em compêndio oficial para análise deste composto. Então, o objetivo deste trabalho foi desenvolver e validar um método espectrofotométrico, simples, rápido e reprodutível para análise de TC em matéria-prima, e em formulação farmacêutica tópica contendo TC. As condições estabelecidas foram: metanol como o solvente de extração, e detecção no comprimento de onda de 309 nm por espectrofotometria no UV. Todos os testes seguiram as normas da RDC 166, 2017. O método proposto foi seletivo. A linearidade foi demonstrada na faixa de concentração de 1 a 8 µg/mL (r = 0.999). A repetibilidade e a precisão intermediária foram confirmadas pelos valores baixos de desvio padrão relativo de 1,53% e 2,70% para a TC, e de 1,73% e 2,91% para a formulação contendo TC. A exatidão, avaliada por meio de testes de recuperação, foi adequada, com mínimo de 98,24% e máximo de 100,04% de recuperação. Observou-se que pequenas modificações no método não interferiram nos resultados, demonstrando que o método é robusto. Os resultados demonstraram que o método foi adequado para a finalidade pretendida, barato, de fácil aplicação, seletivo, linear, preciso, exato e robusto para determinação de TC, e de formulação contendo TC. Então o método desenvolvido satisfaz as necessidades de um método analítico para determinação de TC, e de formulação tópica contendo TC, e é eficaz, inovador e pode contribuir para o desenvolvimento da área farmacêutica.
RESUMO
Resumen El presente trabajo fue realizado por el Grupo de Trabajo Gestión de Acreditación de la Confederación Latinoamericana de Bioquímica Clínica (COLABIOCLI) con el objetivo de conocer el estado de los Laboratorios Clínicos (LC) con respecto a la gestión de la calidad y el estatus de la acreditación ISO 15189 en Latinoamérica. La investigación fue de tipo observacional, transversal y descriptiva; se utilizó como herramienta la encuesta y como instrumento el cuestionario. Los resultados se expresaron en frecuencias simples y porcentajes y se analizaron por estadística descriptiva. En las 253 encuestas aceptadas participaron LC de 15 de 16 países integrantes de COLABIOCLI. El 80% de los LC tenían procedimientos de la fase preanalítica y posanalítica. Más del 85% contaba con registros de gestión de la calidad y participaban en programas de evaluación externa de la calidad (PEEC), principalmente en las disciplinas de química clínica (mayor del 80%) y hematología (mayor del 70%). El 7,51% estaban acreditados por ISO 15189 y 10,27% certificados por ISO 9001. La gestión de la calidad y los PEEC presentan un importante avance en los LC de Latinoamérica; sin embargo, es deseable que todas las partes interesadas armonicen intereses, para que este proceso sea introducido paulatinamente y como parte de las normativas y/o regulaciones obligatorias respectivas, lo que podrá contribuir a que más LC se acrediten en base a ISO 15189 en la región.
Abstract The present work was carried out by the Accreditation Management Working Group of the Latin American Confederation of Clinical Biochemistry (COLABIOCLI) with the aim of knowing the status of Clinical Laboratories (LC, for its acronym in Spanish) with respect to quality management and the status of the ISO 15189 accreditation in Latin America. The research was observational, cross-sectional, and descriptive, using the survey as a tool and the questionnaire as an instrument. The results were expressed in simple frequencies and percentages and analysed by descriptive statistics. LCs from 15 of the 16 member countries of COLABIOCLI participated in the 253 surveys accepted. Eighty percent of LCs had pre-analytical and post-analytic procedures, and more than 85% had quality management records and participated in external quality assessment services (EQAS), mainly in the disciplines of clinical chemistry (greater than 80%) and hematology (greater than 70%); 7.51% were ISO 15189 accredited and 10.27% ISO 9001 certified. Although quality management and EQAS represent an important advance in LCs in Latin America, it is desirable that all stakeholders harmonise interests, so that this process is introduced gradually and as part of the respective mandatory standards and/or regulations, thus contributing to more LCs being accredited based on ISO 15189 in the region.
Resumo O presente trabalho foi realizado pelo Grupo de Trabalho de Gestão de Acreditação da Confederação Latino-Americana de Bioquímica Clínica (COLABIOCLI) com o objetivo de conhecer o status dos Laboratórios Clínicos (LC) com relação à gestão da qualidade e o status da acreditação ISO 15189 na América Latina. A pesquisa foi observacional, transversal e descritiva, utilizando a enquete como ferramenta e o questionário como instrumento. Os resultados foram expressos em frequências simples e porcentagens e analisados por estatística descritiva. LCs de 15 dos 16 países membros do COLABIOCLI participaram das 253 pesquisas aceitas; 80% dos LCs tinham procedimentos da fase pré-analítica e pós-analítica, e mais de 85% tinham registros de gestão da qualidade e participavam de programas de avaliação externa da qualidade (PEEC), principalmente nas disciplinas de química clínica (maior de 80%) e hematologia (maior de 70%); 7,51% estavam acreditados pela ISO 15189 e 10,27% certificados pela ISO 9001. Embora a gestão da qualidade e os PEECs apresentem um importante avanço nos LCs da América Latina, é desejável que todas as partes interessadas harmonizem interesses, para que esse processo seja introduzido gradualmente e como parte das respectivas normas e/ou regulações obrigatórias, o que poderá contribuir para que mais LCs sejam acreditados com base na ISO 15189 na região.
RESUMO
Todos os procedimentos da indústria farmacêutica devem ser validados com a finalidade de garantir que os métodos demonstrem resultados confiáveis e aceitáveis pelo controle de qualidade. Assim, este estudo objetivou validar a eficácia de desinfetantes após diluição para uso em laboratório farmacêutico oficial. Foi elaborado o protocolo de validação e após sua aprovação foi iniciada a diluição dos desinfetantes para os tempos (T) 0, 7, 15 e 30 dias. Foram preparados os meios de cultura, realizada a promoção de crescimento dos microrganismos, preparada a suspensão microbiana e após a incubação foi realizada a diluição seriada de 10-1 a 10-10, o inóculo foi padronizado e a eficácia foi analisada. Os testes de eficácia foram realizados em triplicata, as colônias foram lidas nas placas e os dados planilhados eletronicamente. Do T0 ao T7, todos os microrganismos foram sensíveis aos desinfetantes, exceto Aspergillus brasiliensis, que reprovou três desinfetantes. A partir do T15, os microrganismos Pseudomonas aeruginosa e Bacillus subtilis apresentaram crescimento. No T30, Escherichia coli, Salmonella typhimurium, Staphylococcus aureus e Candida albicans continuaram sem crescimento. Foram aprovados cinco desinfetantes que inibiram o crescimento no período de até 7 dias, sendo definido o prazo de 7 dias como validade para os desinfetantes após diluição.
All procedures in the pharmaceutical industry must be validated to ensure that the methods show reliable and acceptable results according to quality control. This study aimed to validate the efficacy of disinfectants after dilution for use in official pharmaceutical laboratory. The validation protocol was elaborated and, after its approval, the dilution of the disinfectants for the times (T) 0, 7, 15, and 30 days was initiated. The culture media were prepared, the growth of the microorganisms was promoted, the microbial suspension was prepared, and after incubation the serial dilution of 10-1 to 10-10 was performed, the inoculum was standardized, and the efficacy was analyzed. Efficacy tests were performed in triplicates, the colonies were read on the plates, and the data were electronically arranged in spreadsheets. From T0 to T7, all microorganisms were sensitive to disinfectants, except for Aspergillus brasiliensis, which excluded three disinfectants. The microorganisms Pseudomonas aeruginosa and Bacillus subtilis showed growth from T15 onward. At T30, Escherichia coli, Salmonella typhimurium, Staphylococcus aureus, and Candida albicans continued to lack growth. The protocol of this study approved five disinfectants that inhibited growth in a period of up to 7 days and defined 7 days as the validity period for disinfectants after dilution.
Todos los procedimientos de la industria farmacéutica deben ser validados para garantizar que los métodos demuestren resultados confiables y aceptables por el control de calidad. Este estudio tuvo por objetivo validar la eficacia de los desinfectantes diluidos para su uso en laboratorio farmacéutico oficial. Para ello, se elaboró el protocolo de validación y, luego de su aprobación, se inició la dilución de los desinfectantes para los tiempos (T) 0, 7, 15 y 30 días. Se prepararon los medios de cultivo, se promovió el crecimiento de los microorganismos, se preparó la suspensión microbiana, y después de la incubación se realizó la dilución seriada de 10-1 a 10-10, se estandarizó el inóculo y se analizó la eficacia. Las pruebas de eficacia se realizaron por triplicado, las colonias se analizaron en las placas cuyos resultados se pusieron en hojas de cálculo en línea. De T0 a T7, todos los microorganismos fueron sensibles a los desinfectantes, excepto Aspergillus brasiliensis, que falló tres desinfectantes. A partir de T15, los microorganismos Pseudomonas aeruginosa y Bacillus subtilis mostraron crecimiento. En T30, Escherichia coli, Salmonella typhimurium, Staphylococcus aureus y Candida albicans continuaron sin crecimiento. Se aprobaron cinco desinfectantes que inhibieron el crecimiento en un período de hasta 7 días, y se definió un período de 7 días como el período de validez de los desinfectantes después de la dilución.
RESUMO
This article deals with the particularities of the quality of qualitative research, under the double lens of valuing it and ensuring it. While achieving the quality of qualitative research concerns only those who have opted for this methodology, assessing it is everyone's business because researchers in training will encounter, in the literature reviews, qualitative studies on which they must reflect and estimate their quality. Appreciating the quality of a research work is a complex activity as it is situated within a context and conducted by individuals who use any of the means available to do so. The means they use are criteria as evaluation guides and criteria checklists. For researchers in training, I suggest some guiding criteria to evaluate qualitative publications and ensure quality during the research process, key issues that they must address.
Este artículo trata sobre las particularidades de la calidad de la investigación cualitativa, bajo la doble lente de valorarla y asegurarla. Mientras que alcanzar la calidad de una investigación cualitativa atañe solo a los que han optado por esta metodología, valorarla es asunto de todos, ya que los investigadores en formación se encontrarán en las revisiones bibliográficas con estudios cualitativos sobre los cuales deberán reflexionar y estimar su calidad. Apreciar la calidad de un trabajo de investigación es una actividad compleja ya que está situada en un contexto y llevada a cabo por personas que usan alguno de los medios disponibles para hacerlo. Los medios que usan son los criterios como guías de evaluación y los listados de verificación de criterios. Para los investigadores en formación sugiero unos criterios guía para la valoración de publicaciones cualitativas y para asegurar la calidad durante el proceso de investigación, unas cuestiones claves a las que deben atender.
Este artigo trata das particularidades da qualidade da pesquisa qualitativa, sob a dupla lente de valorizá-la e garanti-la. Embora alcançar a qualidade da pesquisa qualitativa seja do interesse de quem optou por esta metodologia, Avaliar é tarefa de todos, pois os pesquisadores em formação se encontrarão em revisões bibliográficas com estudos qualitativos, sobre os quais deverão refletir e estimar sua qualidade. Avaliar a qualidade de um trabalho de investigação é uma atividade complexa, pois está situada num context e é realizada por pessoas que utilizam qualquer um dos meios disponíveis para o fazer. Os meios que utilizam são critérios como guias de avaliação e listas de verificação de critérios. Aos pesquisadores em formação, sugiro alguns critérios norteadores para avaliar publicações qualitativas e para garantir a qualidade durante o processo de pesquisa, questões chaves que devem ser abordadas.
Assuntos
Humanos , Controle de Qualidade , Pesquisa , Pesquisa em Enfermagem , Avaliação da Pesquisa em SaúdeRESUMO
Resumen La participación en programas de evaluación externa de la calidad (PEEC) dirigidos al diagnóstico de enfermedades genéticas permite obtener una medida objetiva del desempeño técnico y analítico de los laboratorios y es un requisito para la acreditación de los laboratorios clínicos bajo la norma ISO 15189. El objetivo de este estudio fue evaluar retrospectivamente el desempeño en los esquemas EMQN (European Molecular Genetics Quality Network) y CF Network (Cystic Fibrosis European Network) en el período 2014-2022. Se participó en un total de 88 esquemas. Se recolectó la información de nuestros puntajes y las medias de los laboratorios participantes en las categorías genotipificación, interpretación y exactitud de la información del paciente/informe. Se informó en forma completa el 90,9% (n=80) de los esquemas. El desempeño en genotipificación mostró puntajes superiores a la media en el 89,3% de los esquemas; 0,8% de los informes correspondieron a falsos negativos. En interpretación, el 66,7% de los esquemas evidenció un desempeño superior a la media y el 33,3% debajo de la media. La exactitud de la información del paciente/informe presentó puntajes superiores a la media en el 97,6% de los esquemas. Se observó una diferencia estadísticamente significativa en el porcentaje de esquemas con puntaje por encima de la media en el año 2022 (10/12 esquemas) respecto al año 2014 (1/6 esquemas) en la categoría interpretación (p=0,0128). En conclusión, la participación regular en PEEC tuvo impacto positivo en la calidad de los estudios y permite realizar mejoras continuas a partir de las recomendaciones sugeridas por estos programas.
Abstract Participation in external quality assessment programmes focused on rare genetic diseases makes it possible to assess the laboratory technical and analytical performance and it is a prerequisite for accreditation according to ISO 15189. The objective of this study was to perform a retrospective evaluation of our performance in the EMQN (European Molecular Genetics Quality Network) and the CF Network (Cystic Fibrosis European Network) programmes in the 2014-2022 period. The laboratory performance on genotyping, interpretation and clerical accuracy and patient identifiers in a total of 88 schemes were assessed. The information of our scores and the mean scores of all participating laboratories in the three categories were collected. A total of 90.9% of the schemes were fully completed. The performance in genotyping showed scores above the mean scores in 89.3% of the schemes; 0.8% of the reports correspond to false negative results. Regarding interpretation category, 66.7% of the schemes presented scores above the mean scores and 33.3% below the mean scores. The clerical accuracy and patient identifiers were above the mean scores in 97.6% of the schemes. A statistically significant difference in the percentage of schemes with a score above the mean for the interpretation category in the year 2022 (10/12 schemes) was observed compared to the year 2014 (1/6 schemes) (p=0.0128). In conclusion, regular participation in external quality assessment programmes had a positive impact on the quality of the studies and allows for continuous improvements based on the recommendations suggested by these programmes.
Resumo A participação em programas de avaliação externa da qualidade (PEECs) voltados para o diagnóstico de doenças genéticas permite obter uma mensuração objetiva do desempenho técnico e analítico dos laboratórios e é requisito para a acreditação dos laboratórios clínicos sob a norma ISO 15189. O objetivo desse estudo foi avaliar retrospectivamente o desempenho nos esquemas EMQN (European Molecular Genetics Quality Network) e CF Network (Cystic Fibrosis European Network) no período 2014-2022. Participou-se em um total de 88 esquemas. Foram coletadas informações de nossos escores e das médias dos laboratórios participantes nas categorias genotipagem, interpretação e precisão da informação do paciente/laudo. 90,9% (n=80) dos esquemas foram informados em sua totalidade. O desempenho na genotipagem apresentou escores acima da média em 89,3% dos esquemas; 0,8% dos laudos corresponderam a falsos negativos. Na interpretação, 66,7% dos esquemas apresentaram desempenho acima da média e 33,3% abaixo da média. A precisão das informações do paciente/laudo apresentou escores acima da média em 97,6% dos esquemas. Observou-se diferença estatisticamente significativa no percentual de esquemas com pontuação acima da média no ano de 2022 (10/12 esquemas) em relação ao ano de 2014 (1/6 esquemas) na categoria interpretação (p=0,0128). Em conclusão, a participação regular em PEECs teve um impacto positivo na qualidade dos estudos e permite fazer melhorias contínuas com base nas recomendações sugeridas por esses programas.
RESUMO
O Limonium brasiliense (Boiss.) Kuntze (Plumbaginaceae), chamado popularmente de baicuru ou guaicuru é uma erva perene presente em todo litoral sul do Brasil, sendo indicada tradicionalmente para síndrome pré-menstrual e distúrbios menstruais. Essas atividades são atribuídas à presença dos polifenóis concentrados em seus rizomas, que também apresentam atividades bacteriostáticas, antioxidantes, antivirais e anti-inflamatórias. No desenvolvimento de formulações feitas a partir da droga vegetal são necessários testes de controle de qualidade durante todo o processo a fim de garantir a segurança, eficácia e qualidade da matéria-prima até sua formulação final. As metodologias utilizadas no desenvolvimento deste trabalho foram de análises físico-químicas para o controle de qualidade, análises quantitativas para determinação do teor de polifenóis totais e, por fim, uma análise comparativa entre os resultados obtidos no ano da coleta do material vegetal (2010) e das mesmas características após 13 anos da coleta, utilizando amostras do L. brasiliense com a presença de fungos ou sem nos rizomas. Sendo assim, este trabalho teve como objetivo realizar o controle de qualidade comparativo dos rizomas de Limonium brasiliense coletados em 2010 em relação ao teor de polifenóis totais e de umidade em 2023. Os resultados obtidos evidenciaram a produção de polifenóis pelos fungos na amostra contaminada, além de mostrarem a qualidade de armazenagem da droga vegetal. Com isso, foi possível concluir que o teor de polifenóis totais da amostra com fungo aumentou após 13 anos da coleta, e que neste interim não houve mudanças no teor de umidade da amostra sem fungo, garantindo sua qualidade no desenvolvimento de formulações ou pesquisas futuras.
Limonium brasiliense (Boiss.) Kuntze (Plumbaginaceae), popularly called baicuru or guaicuru, is a perennial herb present throughout the southern coast of Brazil, traditionally indicated for premenstrual syndrome and menstrual disorders. These activities are attributed to the presence of polyphenols concentrated in its rhizomes, which also have bacteriostatic, antioxidant, antiviral and anti-inflammatory activities. When developing formulations made from plant-based drugs, quality control tests are necessary throughout the process to ensure the safety, efficacy and quality of the raw material until its final formulation. The methodologies used in the development of this work were physical-chemical analyzes for quality control, quantitative analyzes to determine the total polyphenol content and, finally, a comparative analysis between the results obtained in the year the plant material was collected (2010) and the same characteristics after 13 years of collection, using samples of L. brasiliense with or without the presence of fungi in the rhizomes. Therefore, this work aimed to carry out comparative quality control of Limonium brasiliense rhizomes collected in 2010 in relation to the content of total polyphenols and moisture in 2023. The results obtained showed the production of polyphenols by fungi in the contaminated sample, in addition to show the storage quality of the plant drug. With this, it was possible to conclude that the total polyphenol content of the sample with fungus increased after 13 years of collection, and that in the meantime there were no changes in the moisture content of the sample without fungus, guaranteeing its quality in the development of formulations or future research.
Limonium brasiliense (Boiss.) Kuntze (Plumbaginaceae), popularmente llamada baicuru o guaicuru, es una hierba perenne presente en toda la costa sur de Brasil, tradicionalmente indicada para el síndrome premenstrual y trastornos menstruales. Estas actividades se atribuyen a la presencia de polifenoles concentrados en sus rizomas, que también tienen actividades bacteriostáticas, antioxidantes, antivirales y antiinflamatorias. Cuando se desarrollan formulaciones elaboradas a partir de medicamentos de origen vegetal, son necesarios ensayos de control de calidad durante todo el proceso para garantizar la seguridad, eficacia y calidad de la materia prima hasta su formulación final. Las metodologías utilizadas en el desarrollo de este trabajo fueron análisis físico- químicos para control de calidad, análisis cuantitativos para determinar el contenido de polifenoles totales y, finalmente, un análisis comparativo entre los resultados obtenidos en el año de recolección del material vegetal (2010) y el mismas características después de 13 años de colecta, utilizando muestras de L. brasiliense con o sin presencia de hongos en los rizomas. Por lo tanto, este trabajo tuvo como objetivo realizar un control de calidad comparativo de los rizomas de Limonium brasiliense recolectados en 2010 en relación al contenido de polifenoles totales y humedad en 2023. Los resultados obtenidos mostraron la producción de polifenoles por hongos en la muestra contaminada, además de mostrar la calidad de almacenamiento de la droga vegetal. Con esto se pudo concluir que el contenido total de polifenoles de la muestra con hongos aumentó después de 13 años de colecta, y que mientras tanto no hubo cambios en el contenido de humedad de la muestra sin hongos, garantizando su calidad en el desarrollo. de formulaciones o investigaciones futuras.
RESUMO
OBJECTIVE: To evaluate the quality of the human milk expressed at home and at a human milk bank. METHODS: This a retrospective, analytical, and observational study, performed by assessing titratable acidity records and the microbiological culture of 100 human milk samples expressed at home and at a human milk bank, in 2014. For the statistical analysis, generalized estimating equations (GEE) and the chi-squared test were used. RESULTS: When comparing the two sample groups, no significant difference was found, with 98% and 94% of the samples being approved among those collected at the milk bank and at home, respectively. No main interaction effect between local and titratable acidity records (p=0.285) was observed, and there was no statistically significant difference between the expected and observed values for the association between the collection place and the microbiological culture results (p=0.307). CONCLUSIONS: The quality of human milk expressed at home and at the milk bank are in agreement with the recommended standards, confirming that the expression of human milk at home is as safe as expression at the human milk bank, provided that the established hygiene, conservation, storage, and transport standards are followed.
Assuntos
Extração de Leite/métodos , Bancos de Leite Humano/normas , Leite Humano/química , Leite Humano/microbiologia , Feminino , Manipulação de Alimentos , Humanos , Refrigeração , Estudos RetrospectivosRESUMO
ABSTRACT Objective. To evaluate the screening of blood samples for infectious disease markers at laboratories and blood banks in Latin America per the findings of an External Quality Assessment Program (EQAP). Methods. This qualitative analysis used data from the EQAP coordinated by the Fundação Pro Sangue Hemocentro de São Paulo with the support of the Pan American Health Organization to assess the performance of blood screening for infectious diseases from 2014 to 2018 in Latin America. Each participating laboratory or blood bank received an identical blind panel with 24 blood samples with variable reactivity for all the screening parameters. Panels were processed at each participating facility and results were returned to the Fundação Pro Sangue Hemocentro de São Paulo for individual and joint analyses. Two types of discrepant results were potential failures: false positive results (FPRs) and false nonreactive results (FNRRs). Results. A total of 23 136 samples were evaluated. Global rates of FPR, FNRR, and concordant results were 0.3%, 1.0% and 98.7%, respectively. Seven FNRRs were found for HBsAg (1.0%), 12 for syphilis (2.6%), and 21 for Chagas disease (2.9%). No FNRRs were found for the HIV, HCV, and HTLV viruses. The average accuracy of all the laboratories and blood banks participating in the EQAP during the study period was 99.5% (standard deviation, 0.5%). Conclusion. The findings of this qualitative analysis are positive for blood safety in Latin America, with an average accuracy of 99.5% among the participating laboratories and blood banks. This report reflects an important improvement in blood bank serological screening EQAP-PAHO report since the 2003.
RESUMEN Objetivo. Evaluar el tamizaje de muestras de sangre en las que se analizan marcadores de enfermedades infecciosas en laboratorios y bancos de sangre de América Latina según los resultados de un programa de evaluación externa de la calidad (EQAP, por su sigla en inglés). Métodos. Este análisis cualitativo utilizó datos del EQAP —coordinado por la Fundação Pro Sangue Hemocentro de São Paulo con el apoyo de la Organización Panamericana de la Salud— para evaluar la eficacia del tamizaje sanguíneo para la detección de enfermedades infecciosas que se realizó entre el 2014 y el 2018 en América Latina. Cada laboratorio o banco de sangre participante recibió un panel idéntico para análisis a ciegas compuesto por 24 muestras de sangre con reactividad variable para todos los parámetros del tamizaje. Los paneles se procesaron en cada establecimiento participante y los resultados se enviaron a la Fundação Pro Sangue Hemocentro de São Paulo donde se realizaron análisis individuales y conjuntos. Había dos tipos de resultados discrepantes que eran posibles fallas del tamizaje: los positivos falsos (PF) y los negativos falsos (NF). Resultados. En total se evaluaron 23 136 muestras. Las tasas generales de PF, NF y resultados concordantes fueron, respectivamente, del 0,3%, 1,0% y 98,7%. Se obtuvieron siete NF en casos de HBsAg (1,0%), 12 en casos de sífilis (2,6%) y 21 en casos de enfermedad de Chagas (2,9%). No se obtuvieron NF en casos de infección por virus del VIH, el VHC o el VLTH. La precisión promedio de todos los laboratorios y bancos de sangre participantes en el EQAP durante el periodo de estudio fue del 99,5% (desviación típica: 0,5%). Conclusión. Los resultados de este análisis cualitativo son positivos en lo referente a la seguridad sanguínea en América Latina, con una precisión promedio del 99,5% entre los laboratorios y bancos de sangre participantes. Este informe refleja la considerable mejora del tamizaje serológico que se realiza en los bancos de sangre, en comparación con los resultados del informe del EQAP que contó con el apoyo de la OPS y se publicó en el 2003.
RESUMO Objetivo. Avaliar a triagem de marcadores de doenças infecciosas em amostras de sangue realizada em laboratórios e bancos de sangue da América Latina de acordo com os resultados de um Programa Externo de Avaliação de Qualidade (EQAP, na sigla em inglês). Métodos. Esta análise qualitativa usou dados do EQAP coordenado pela Fundação Pró-Sangue Hemocentro de São Paulo, com o apoio da Organização Pan-Americana da Saúde, para avaliar o desempenho da triagem de sangue quanto a doenças infecciosas no período de 2014 a 2018 na América Latina. Cada laboratório ou banco de sangue participante recebeu um painel cego idêntico com 24 amostras de sangue de reatividade variável para todos os parâmetros de triagem. Os painéis foram processados em cada estabelecimento participante e os resultados foram devolvidos à Fundação Pró-Sangue Hemocentro de São Paulo para análises individuais e conjuntas. Dois tipos de resultados discrepantes representavam falhas em potencial: resultados falso-positivos e resultados falso-negativos (não reativos). Resultados. Foram avaliadas 23.136 amostras. As taxas globais de resultados falso-positivos, falso-negativos e concordantes foram de 0,3%, 1,0% e 98,7%, respectivamente. Foram encontrados sete resultados falso-negativos para HBsAg (1,0%), 12 para sífilis (2,6%) e 21 para doença de Chagas (2,9%). Não houve resultados falso-negativos para os vírus HIV, HCV e HTLV. A acurácia média de todos os laboratórios e bancos de sangue que participaram do EQAP durante o período do estudo foi de 99,5% (desvio padrão de 0,5%). Conclusões. Os resultados desta análise qualitativa são positivos para a segurança do sangue na América Latina, com uma acurácia média de 99,5% entre os laboratórios e bancos de sangue participantes. Este relatório reflete uma melhoria importante na triagem sorológica dos bancos de sangue em relação aos resultados do relatório do EQAP apoiado pela OPAS que foi publicado em 2003.
RESUMO
A indústria farmacêutica deve cumprir os requisitos de boas práticas de fabricação para reduzir os riscos de contaminação inerentes ao processo produtivo. Bacillus e gêneros relacionados estão entre as principais bactérias isoladas de áreas limpas, matérias-primas e produtos das indústrias farmacêuticas, mas a correta identificação dessas espécies ainda é um desafio. O objetivo deste estudo foi caracterizar por fenotipagem, perfil proteico e sequenciamento do gene 16S rRNA cepas de Sutcliffiellahorikoshii (n = 6) isoladas de uma instalação farmacêutica imunobiológica, e propor a reclassificação de Bacillus tianshenii para o gênero Sutcliffiella, e Sutcliffiella tianshenii sp. . novembro. As cepas foram caracterizadas por VITEK®2, tempo de voo/espectrometria de massa por dessorção a laser assistida por matriz (MALDI-TOF/MS) usando VITEK®MS e análise de sequenciamento do gene 16S rRNA. MALDI-TOF/MS não identificou nenhuma cepa que tenha sido identificada pelo 16S rRNA como S. horikoshii. VITEK®2 apresentou resultados falso-positivos, com identificação incorreta como B. sporothermodurans (reclassificada como Heyndrickxia sporothermodurans) e Geobacillus thermoleovorans. Após a expansão da base de dados MALDI-TOF/MS, com a criação do SuperSpectrum, as cepas foram corretamente identificadas como S. horikoshii. Este estudo é o primeiro relato de isolamento de cepas de S. horikoshii de uma indústria farmacêutica. Mais estudos são necessários para compreender melhor a capacidade de S. horikoshii de contaminar o meio ambiente e os produtos.
Assuntos
Controle de QualidadeRESUMO
Introducción: La satisfacción de los integrantes de una organización de cualquier tipo y, en particular, de aquellas que prestan servicios médicos es un tema de mucho interés e importancia si de lograr altos niveles de satisfacción y, por ende, de lealtad de los pacientes y sus familiares se trata. Objetivo: Determinar las dimensiones y atributos para la satisfacción y lealtad del cliente interno en instituciones de salud en Barranquilla durante el año 2021. Método: Se realizó un estudio exploratorio descriptivo en instalaciones relacionadas con los servicios de salud en Barranquilla en 367 funcionarios (n=367) aunado con la revisión de la literatura correspondiente. Se aplicó un cuestionario con el fin de conocer las dimensiones y atributos antes mencionados. Los atributos fueron agrupados por eje de acuerdo a su mayor peso y sobre la base de esto fue definida el nombre de las dimensiones considerando diversos estudios realizados y la experiencia. Se realizaron pruebas para determinar fiabilidad y validez para la encuesta, así como pruebas de adecuación muestral. Se aplicó el análisis factorial y componentes principales. Resultados: El 79 % de la varianza total abarcó las dimensiones: trabajo en equipo, reconocimiento laboral, condiciones de trabajo y beneficios laborales. Se mostró una distribución de los atributos en las dimensiones capaz de explicar la situación en un alto nivel. Conclusiones: El cliente interno es factor clave en una organización, considerándose adecuados los atributos propuestos para la satisfacción y lealtad del mismo en instituciones de salud.
Introduction: Satisfaction of internal members of any organization, in particular those which provide medical services, is of a great interest and importance when it comes to achieve high levels of satisfaction and, therefore, loyalty of both patients and their families. Objective: To determine dimensions and attributes to get internal customer satisfaction and loyalty in health institutions in Barranquilla, throughout 2021. Method: An exploratory descriptive study was carried out in healthcare facilities in Barranquilla. The study was conducted in 367 health officials (n=367). Also it was carried out a review of related literature. It was applied a questionnaire to determine the dimensions and attributes. The attributes were grouped by axis according to those with widest impact and, based on this assess, the name of the dimensions was defined taken into account various previous studies and experiences. Factor and principal component analyses were applied. Results: The 79 % of the total variance covered the following dimensions: teamwork, job recognition, working conditions and work benefits. The attributes distributed in the dimensions can certify the high level found. Conclusions: The internal customer is a key factor in any institution, and the proposed attributes for customer satisfaction and loyalty in health institutions are considered adequate.
Introdução: A satisfação dos membros de uma organização de qualquer tipo e, em particular, daqueles que prestam serviços médicos é um tema de grande interesse e importância se pretendemos alcançar elevados níveis de satisfação e, portanto, de fidelização dos pacientes e seus parentes são tratados. Objetivo: Determinar as dimensões e atributos para a satisfação e lealdade do cliente interno em instituições de saúde em Barranquilla durante o ano de 2021. Método: Estudo descritivo exploratório realizado em instalações relacionadas a serviços de saúde em Barranquilla em 367 funcionários (n=367) juntamente com a revisão da literatura correspondente. Aplicou-se um questionário para conhecer as dimensões e atributos mencionados. Os atributos foram agrupados por eixo de acordo com seu maior peso e com base nisso foi definido o nome das dimensões considerando diversos estudos e experiências. Foram realizados testes para determinar a confiabilidade e validade da pesquisa, bem como testes de adequação da amostra. Aplicou-se análise fatorial e componentes principais. Resultados: 79% da variância total cobriu as dimensões: trabalho em equipe, reconhecimento do trabalho, condições de trabalho e benefícios do trabalho. Foi apresentada uma distribuição dos atributos nas dimensões, capaz de explicar a situação em alto nível. Conclusões: O cliente interno é um fator chave em uma organização, considerando adequados os atributos propostos para a satisfação e fidelização do mesmo nas instituições de saúde.
RESUMO
O objetivodo presente estudo foiavaliar a percepção de acadêmicos de Odontologia quanto àqualidade dos serviços prestados no âmbito da clínicade uma universidade privada do Nordeste brasileiro.Trata-se deuma pesquisa quantitativa, de caráter avaliativo e corte transversal realizada com 201 estudantesmatriculadosdo 4º ao 10º semestre de graduação,que prestaram atendimentoclínicoaospacientes.Realizou-se a coleta de dados no período de abril a setembro de 2019, por meio da aplicação de umquestionário contendo 35 questões objetivas, dividido emtrês blocos relacionados a: infraestrutura; qualidade do atendimento clínico; eações gerenciais. Dos 201 participantes, em quesitos relacionados àinfraestrutura, 187 (93%) apontaram adequadas condiçõesde uso, 198 (98,5%)boascondições de limpeza e 188 (93,5%) afirmaram que as instalações da clínicagarantem condições de acessibilidadee mobilidade. Em relação à qualidadedo atendimento, 102 (50,7%) participantes apontaram que houve orientação ao paciente após o tratamento, porém 200 (99,5%) afirmaram que é realizado o encaminhamento entre as clínicas quando necessário para completar otratamento.Para os aspectos gerenciais, 95 (47,3%)indicaramque são disponibilizadoscanais de comunicação aos pacientes, e 156 (77,6%)afirmaramque existe uma relação democrática e cooperativa com a coordenação. Os aspectos da qualidade relacionados ao âmbito da clínica escola foram considerados satisfatórios, contudo,existe anecessidade de uma análise mais aprofundada no processo de comunicação e monitoramento das ações para contínua melhoria da qualidade (AU).
This study aimed to evaluate the perception of academics regarding the quality of services provided within the clinical school of a Dentistry Course at a private university in Northeastern Brazil. Quantitative, evaluative and cross-sectional research carried out with students from the 4th to the 10th semester of graduation. Data collection was carried out from April to September 2019 with 201 participants who provided care to patients at the clinics. A questionnaire adapted from the Quality Assessment Instrument used in public health services was used. The instrument contained three blocks of aspects to be assessed: infrastructure; clinical care and satisfaction; managerial actions. Most participants indicated satisfactory conditions, highlighting the structural building categories (89.6%), cleanliness (98.5%) and accessibility (93.5%). As for the work process, there were positive responses above 80%, but only 50.7% indicated that there was guidance to the patient after assistance. For managerial aspects, 52.7% indicated that communication channels are available to patients and 77.6% stated that there is a democratic and cooperative relationship with the coordination. According to the perception of the interviewees, the aspects of quality related to infrastructure, work process and management actions of the services provided within the clinic were considered satisfactory, with identification of aspects that signal the need for a more in-depth analysis in the process of communication and monitoring of actions for continuous quality improvement (AU).
Assuntos
Humanos , Masculino , Feminino , Controle de Qualidade , Estudantes de Odontologia , Clínicas Odontológicas , Odontologia , Percepção Social , Estudos Transversais/métodos , Inquéritos e Questionários , Melhoria de QualidadeRESUMO
Esse estudo consistiu em analisar a confiabilidade e a eficácia dos métodos do controle interno da qualidade das bioquímicas em um laboratório privado, a partir da criação dos próprios valores de referência, utilizando como ferramentas o gráfico de Levey Jennings e regras de Westgard. Métodos: Foram estabelecidos nesse estudo os próprios valores de referência para cada analito, dispostos os valores de qualidade diários nos gráficos e realizadas as interpretações para validação do teste. Resultados: Através da implementação dos valores próprios de referência e um controle de qualidade mais rígido, foi possível identificar uma melhor estabilidade dos analitos, melhor percepção dos erros aleatórios, sistemáticos e tendenciosos, obtendo informações mais confiáveis e efetivas perante os controles. Conclusão: Os resultados desta análise indicam uma maior estabilidade e uma menor variabilidade dentro dos valores de referência criados, resultando em exames mais precisos e seguros.
Objective: This study consisted of analyzing the reliability and effectiveness of the methods of internal quality control of biochemists in a private laboratory, from the creation os their own reference values, using the Levey-Jennings chart and Westgard rules as tools. Methods: In this study, the reference values for each analyte were created, the daily quality values were displayed on the graphs, and the interpretations were carried out to validate the test. Results: Through the implementation of proper reference values and stricter quality control, it was possible to identify better stability of the analytes, better perception os random, systematic and biased errors, obtaining more reliable and effective information from the controls. Conclusion: The results of this analysis indicate greater stability and less variability within the created reference values, resulting in more accurate examinations.
Assuntos
Controle de Qualidade , Valores de Referência , Regras de Decisão ClínicaRESUMO
Objetivos: Desenvolver e validar um método analítico para a análise simultânea de atorvastatina (ATO), losartana (LOS) e metformina (MTF) em formulações farmacêuticas magistrais por CLAE. Método: O método foi desenvolvido empregando o cromatógrafo a líquido modelo Dionex® Ultimate 3000, acoplado ao detector de arranjo de diodos (DAD) e a validação se deu conforme compêndios de validação internacional e nacional. Os seguintes parâmetros foram analisados: linearidade, precisão, exatidão, robustez, seletividade, LD e LQ. A separação cromatográfica foi realizada na coluna Sigma-Aldrich® C18, fase móvel MeOH:H2O (78:22 v/v), pH 3,0 e vazão de 0,3 mL-min-1, modo isocrático. As detecções foram realizadas nos comprimentos de onda de 225 nm (LOS), 236 nm (MTF) e 246 nm (ATO). Resultados: O método foi linear, com coeficientes de correlação linear (r)> 0,99 para todos os fármacos, preciso (DPR entre medidas < 2 %), exato (recuperação entre 98-102 %). As variações propostas no estudo de robustez não tiveram influência significativa nos resultados, exceto a coluna cromatográfica. O método foi seletivo, pois os excipientes não interferiram nas análises. A sensibilidade do método foi demonstrada através da determinação teórica dos LD e LQ. Conclusão: Os resultados obtidos sugerem que o método cromatográfico desenvolvido e validado nessa pesquisa poderá ser empregado nas análises de rotina dos laboratórios de controle de qualidade de medicamentos contendo esses fármacos de forma isolada ou combinados em formulações farmacêuticas de uso oral.
SUMMARY Aims: To develop and validate an analytical method for the simultaneous analysis of atorvastatin (ATO), losartan (LOS), and metformin (MTF) in pharmaceutical compounding by HPLC. Method: The method was developed using a liquid chromatograph model Dionex® Ultimate 3000, coupled to a diode array detector (DAD), and validation was carried out according to international and national validation compendiums. The following parameters were analyzed: linearity, precision, accuracy, robustness, selectivity, LD, and LQ. Chromatographic separation was performed on a Sigma-Aldrich® C18 column, mobile phase MeOH:H2O (78:22 v/v), pH 3.0, and flow rate of 0.3 mL-min-1, isocratic mode. Detections were performed at 225 nm (LOS), 236 nm (MTF), and 246 nm (ATO) wavelengths. Results: The method was linear, with linear correlation coefficients (r)> 0.99 for all drugs, precise (DPR between measurements < 2 %), accurate recovery (between 98-102 %). The variations proposed in the robustness study had no significant influence on the results, except for the chromatographic column. The method was selective, as the excipients did not interfere in the analyses. The sensitivity of the method was demonstrated through the theoretical determination of LD and LQ. Conclusion: The results obtained suggest that the chromatographic method developed and validated in this research can be used in the routine analyzes of quality control laboratories of drugs containing these drugs alone or combined in pharmaceutical formulations for oral use.
RESUMO
This research was performed to ascertain the most suitable Artificial Neural Network (ANN) model to quantify the degree of fraud in powdered milk through the addition of powdered whey via regular standard physicochemical analyses. In this study, an evaluation was done on 103 samples with different quantities of added whey powder to whole milk powder. Using Fourier Transform Infrared Spectroscopy the fat, cryoscopy, total solids, defatted dry extract, lactose, protein and casein were analyzed. The hyperbolic tangent transformation function was used with 45 topologies, and the Holdback and K-fold validation methods were tested. In the Holdback method, 75% of the database was employed for training, while 25% was used for validation. In the K-fold method, the database was categorized into five equal sized subsets, which alternated between training and validation. Of the two methods, the K-fold method was proven to have superior efficiency. Next, analysis was done on three models of multilayer perceptron networks with feedforward architecture. In Model 1, the input layer contained all the physicochemical analyses conducted, in model 2 the casein analysis was excluded, and in model 3 the routine analyses performed for dairy products was done (fat, defatted dry extract, cryoscopy and total solids). From Model 3 an ANN was derived which could satisfactorily predict fraud calculated from using the routine and standard analyses for dairy products, containing 64 nodes in the hidden layer, with R² of 0.9935 and RMSE of 0.5779 for training, and R² of 0.9964 and RMSE of 0.4358 for validation.
O objetivo do trabalho foi determinar o melhor modelo de rede neural artificial (RNA) para quantificar fraude em leite em pó, pela adição de soro em pó, por meio de analises físico-químicas de rotina. Foram avaliados 103 níveis de adição de soro lácteo em pó em leite em pó integral. As análises de gordura, crioscopia, sólidos totais, extrato seco desengordurado, lactose, proteína e caseína foram realizadas por espectroscopia no infravermelho com transformada de Fourier. A função de transformação utilizada foi a tangente hiperbólica, em que testou-se 45 topologias e dois métodos de validação: holdback e k-fold. Para o método holdback, 75% do banco de dados foi utilizado para o treinamento e 25% para a validação. Para o método k-fold, o banco de dados foi dividido em cinco subconjuntos de mesmo tamanho que se alternavam entre treinamento e validação. O método k-fold se mostrou mais eficiente. Três modelos de redes perceptron de múltiplas camadas com arquitetura feedforward foram analisados. No modelo 1 a camada de entrada constituía todas as análises físico-químicas realizadas, no modelo 2 excluiu-se a análise de caseína e no modelo 3 utilizou-se as análises de rotina em laticínios (gordura, extrato seco desengordurado, crioscopia e sólidos totais). O modelo 3 obteve uma RNA capaz de predizer satisfatoriamente a fraude avaliada a partir de análises consideradas de rotina em laticínios com uma RNA contendo 64 nodos na camada oculta, R² de 0,9935 e RMSE de 0,5779 para treinamento, R² de 0,9964 e RMSE de 0,4358 para validação.
Assuntos
Contaminação de Alimentos/análise , Redes Neurais de Computação , Leite em Pó Integral , FraudeRESUMO
Introdução: Os desvios da qualidade de medicamentos (DQM) apresentam grande relevância no âmbito da farmacovigilância, devendo ser investigados e monitorados, uma vez que podem levar a uma grande variedade de desfechos clínicos. Objetivo: Discutir sobre a caracterização dos DQM no âmbito da farmacovigilância por meio de uma revisão narrativa da literatura. Método: Foi realizada uma busca abrangente em bases de dados utilizando-se os descritores: "farmacovigilância", "queixas técnicas (QT)", "DQM" e "sistemas de notificação", incluindo estudos relacionados diretamente ao tema proposto, realizados no Brasil e publicados no período de 2005 a 2020. Resultados: Os DQM podem estar relacionados a alterações no próprio medicamento, ao conteúdo e integridade da embalagem e à rotulagem. Dos 18 estudos selecionados (14 artigos, dois capítulos de livro e duas dissertações) contendo notificações de DQM na forma de QT de medicamentos, dois avaliaram exclusivamente notificações de QT de medicamentos (100,0%), enquanto o restante apontou que estas representavam de 0,6% a 70,0% do total de notificações realizadas em estabelecimentos de saúde do país. Os principais DQM evidenciados foram alterações no aspecto do produto, ausência/redução na quantidade do medicamento e problemas nas embalagens. Conclusões: Considera-se que as notificações envolvendo DQM representem um excelente indicador de qualidade dos medicamentos disponíveis no mercado, vindo a contribuir na qualificação de fornecedores e distribuição de produtos conformes à população.
Introduction: Substandard drugs (SD) present great relevance in the area of pharmacovigilance and should be investigated and monitored as they can lead to several clinical outcomes. Objective: To discuss the characteristics of SD in the area of pharmacovigilance through a narrative review. Method: A comprehensive search was performed on databases using the descriptors "pharmacovigilance", "technical complaints (TC)", "SD" and "notification systems" including studies directly concerning the subject conducted in Brazil and published between 2005 and 2020. Results: SD issues might be associated with drug product alterations, content and integrity of the package and labeling. Among the 18 selected studies (14 articles, two book chapters and two dissertations) regarding SD notifications reported as drug TC, two exclusively evaluated drug TC notifications (100.0%), while the rest showed that this type of notification represented 0.6% to 70.0% of the total of notifications made in national health establishments. The main SD issues found were: alterations on the product aspect; absence/reduction in the amount of drug product; and, package problems. Conclusions: Notifications involving SD issues are considered an excellent quality indicator for the drugs available in the market, which contributes to suppliers' qualification and provision of consistent products for the population.
RESUMO
Objetivo: Identificar as causas de não conformidades em Produtos para Saúde distribuídos por um centro de esterilização localizado na região metropolitana de Belo Horizonte, MG, Brasil. Métodos: Estudo descritivo, de natureza quantitativa que foi realizado entre janeiro e dezembro de 2019. Os dados foram coletados através de um instrumento estruturado para avaliação sistemática dos itens e analisados estatisticamente de forma descritiva. Resultados: Foram avaliados 2.944 produtos para saúde, que variou de 66 a 284/mês, com média de 245 (±56). Foram identificados 24 itens inadequados o que gerou uma taxa de não conformidade de 0,96%. As principais causas foram atribuídas à embalagem manchada (20,8%), aos produtos para saúde sem identificação (20,8%), problemas na selagem (16,6%) e embalagem violada (12,5%). Conclusão: As principais causas de não conformidades encontradas sugerem a realização de um controle criterioso de qualidade em cada etapa do reprocessamento de materiais para não comprometer a segurança do paciente.
Objective: To identify the causes of non-conformities in Health Products distributed by a sterilization center located in the metropolitan region of Belo Horizonte, MG, Brazil. Methods: This was a study described, of a quantitative nature that was carried out between January and December 2019. The data were collected through a structured instrument for systematic evaluation of the items and analyzed using the technique of descriptive statistics. Results: A total of 2,944 health products were evaluated during the study period, which ranged from 66 to 284/month, with an average of 245 (± 56). There were 24 inappropriate items that generated a noncompliance rate of 0.96%. The main causes were attributed to stained packaging (20.8%), health products without identification (20.8%), sealing problems (16.6%) and violated packaging (12.5%). Conclusion: The main causes of nonconformities found in this study suggest the performance of a careful quality control at each stage of the reprocessing cycle so as not to compromise patient safety.
Assuntos
Vigilância de Produtos Comercializados , Controle de Qualidade , Instrumentos Cirúrgicos , Esterilização , EnfermagemRESUMO
Objetivo: desarrollar y validar un método simple, sensible y rápido para la determinación simultánea de sulfametoxazol (SMT), trimetoprima (TMP) y bromhexina (BMX) en formulación veterinaria por cromatografía líquida de alta resolución de acuerdo con las directrices de validación y control. Guía para la calidad analítica de medicamentos en productos alimenticios y medicamentos veterinarios, RDC 166/2017 y guías internacionales Conferencia Internacional sobre Armonización y Asociación Internacional de Químicos Analíticos Oficiales. Materiales y métodos: la separación se realizó en una columna analítica ThermoScientific® C18 AcclaimTM120 (4,6 x 250 mm, 5 µm), con caudal de 0,7 mL min-1 y detección a 245 nm, 265 nm y 271 nm, para BMX, SMT y TMP, respectivamente. Todas las mediciones se realizaron en metanol:agua (84:16 v/v; pH 3,0). Las curvas analíticas fueron lineales (r > 0,9997) en el rango de concentración de 15.0 a 30.0 µg-mL-1 para SMT, 3.0 a 9.0 µg-mL-1 para TMP y 0,5 a 2,0 µg-mL-1 para BMX. Resultados: el método demostró ser preciso con coeficientes de variación por debajo del límite máximo de 2,0%, robusto, sin influencia significativa de las variaciones utilizadas en el análisis, exacto (recuperación >99%) y selectivo, en la evaluación de la interferencia de adyuvantes Conclusión: por lo tanto, el método desarrollado demostró ser adecuado para los análisis de control de calidad de rutina para la determinación simultánea de SMT, TMP y BMX en formulaciones farmacéuticas.
SUMMARY Aim: To develop and to validate a simple, sensitive and fast method for the simultaneous determination of sulfamethoxazole (SMT), trimethoprim (TMP) and bromhexine (BMX) in veterinary formulation by high performance liquid chromatography according to the guidelines of the Validation and Control Guide for analytical quality of medicines in food products and veterinary medicines, RDC 166/2017 and international guides International Conference on Harmonization and International Association of Official Analytical Chemists. Materials and methods: The separation was performed on a ThermoScientific® C18 AcclaimTM120 analytical column (4.6 X 250 mm, 5 µm), with a flow rate of 0.7 mL min-1 and detection at 245 nm, 265 nm and 271 nm, for BMX, SMT and TMP, respectively. All measurements were performed in methanol: water (84:16 v/v; pH 3.0). The analytical curves were linear (r > 0.9997) in the concentration range of 15.0 to 30.0 µg-mL-1 for SMT, 3.0 to 9.0 µg-mL-1 for TMP and 0.5 to 2.0 µg-mL-1 for BMX. Results: The method proved to be accurate, with coefficients of variation below the maximum limit of 2.0%, robust, without significant influence of the variations used in the analysis, exact (recovery >99%) and selective, in the assessment of interference from adjuvants. Conclusion: Therefore, the developed method proved to be suitable for routine quality control analyzes for the simultaneous determination of SMT, TMP and BMX in pharmaceutical formulations.
Objetivo: desenvolver e validar um método simples, sensível e rápido para a determinação simultânea de sulfametoxazol (SMT), trimetoprima (TMP) e bromexina (BMX) em formulação veterinária por cromatografia líquida de alta eficiência de acordo com as diretrizes do Validation and Control Guia de qualidade analítica de medicamentos em produtos alimentícios e medicamentos veterinários, RDC 166/2017 e guias internacionais Conferência Internacional de Harmonização e Associação Internacional de Químicos Analíticos Oficiais. Materiais e métodos: a separação foi realizada em coluna analítica ThermoScientific® C18 AcclaimTM120 (4,6 X 250 mm, 5 µm), com vazão de 0,7 mL min-1 e detecção em 245 nm, 265 nm e 271 nm, para BMX , SMT e TMP, respectivamente. Todas as medições foram realizadas em metanol:água (84:16 v/v; pH 3,0). As curvas analíticas foram lineares (r > 0,9997) na faixa de concentração de 15,0 a 30,0 µg-mL-1 para SMT, 3,0 a 9,0 µg-mL-1 para TMP e 0,5 a 2,0 µg-mL-1 para BMX. Resultados: o método mostrou-se preciso, com coeficientes de variação abaixo do limite máximo de 2,0%, robusto, sem influência significativa das variações utilizadas na análise, exato (recuperação >99%) e seletivo, na avaliação da interferência de adjuvantes. Conclusão: portanto, o método desenvolvido mostrou-se adequado para análises de controle de qualidade de rotina para a determinação simultânea de SMT, TMP e BMX em formulações farmacêuticas.
RESUMO
Abstract Objectives: microbiological quality of raw human milk (HM) from donors at the HMB (Human Milk Bank) of Santa Casa de Misericórdia de Ouro Preto was evaluated. Methods: the microbiological quality of milk from each of 10 donors in triplicate (30 samples) was evaluated by enumeration of Staphylococcus aureus and total aerobic mesophiles (surface plating) and total and thermotolerant coliforms (Most Probable Number - MPN). A questionnaire and a checklist were applied after the end of sample collection to verify the compliance of milk extraction and storage procedures by the donors. Results: inadequacies in the procedures for expression and storage of donated HM were observed. The presence of all microorganisms studied were verified in the milk of all donors, and in some cases exceeded the safety limits. The checklist indicated that some necessary hygienic-sanitary procedures were not carefully performed, making it important to properly guide the donors. Conclusions: this study points to an unfavorable scenario for the safety and quality of donated HM, and it is important to encourage further studies to be conducted so that the Brazilian network of HMB adopts stricter criteria for instructions on procedures and support for HM donors.
Resumo Objetivos: avaliou-se a qualidade microbiológica do leite humano (LH) cru de doadoras do Banco de Leite Humano (BLH) da Santa Casa de Misericórdia de Ouro Preto. Métodos: a qualidade microbiológica do leite de cada uma das 10 doadoras em triplicata (30 amostras) foi avaliada por meio da enumeração de Staphylococcus aureus e mesóflos aeróbios totais (plaqueamento em superfície) e coliformes totais e termotolerantes (Número Mais Provável -NMP). Para verificar a conformidade dos procedimentos de extração e armazenamento do leite pelas doadoras, aplicou-se um questionário e um checklist após o término da coleta das amostras. Resultados: observou-se inadequações nos procedimentos de expressão e armazenamento do LH doado. A presença de todos os microrganismos estudados foram verificados no leite de todas as doadoras e, em alguns casos, excedeu os limites de segurança. O checklist indicou que alguns procedimentos higiênico-sanitários necessários não foram realizados criteriosamente, tornando importante orientar adequadamente as doadoras. Conclusões: este estudo aponta um cenário desfavorável para a segurança e a qualidade do LH doado, sendo importante incentivar mais estudos a serem realizados para que a rede brasileira de BLH adote critérios mais rigorosos de instruções sobre procedimentos e suporte para doadoras de LH.
Assuntos
Humanos , Feminino , Gravidez , Controle de Qualidade , Qualidade dos Alimentos , Bancos de Leite Humano/normas , Extração de Leite/métodos , Microbiologia de Alimentos , Leite Humano/microbiologia , BrasilRESUMO
Introducción: El agua salubre y fácilmente accesible es importante para la salud pública, si se utiliza para beber, uso doméstico, producir alimentos o fines recreativos. El agua contaminada y el saneamiento deficiente están re-lacionados con la transmisión de enfermedades. Objetivo: Evaluar las características físico-químicas y microbiológicas de la red de distribución del acueducto urbano de un municipio de Boyacá. Materiales y métodos: Estudio cuantitativo descriptivo transversal. Se tomaron muestras de agua en 13 puntos, 7 concertados y materializados de la red de distribución, uno en la bocatoma de entrada de la planta, dos pozos y tres nacimientos, de donde se abastece la población. Se realizaron análisis físicos, químicos y microbiológicos de cada una de las muestras. Resultados: En las muestras sin tratamiento hubo concentraciones altas de unidades platino, cobalto y turbiedad. El cloro residual libre en dos muestras de agua tratada estaba por debajo de los límites establecidos. Se detecta-ron microorganismos heterótrofos y coliformes en las muestras de agua obtenidas de fuentes de abastecimiento. En dos puntos se encontraron quistes de Giardia y ooquistes de Cryptosporidium. De las 13 muestras estudiadas, tres arrojaron un índice de riesgo por calidad del agua inviable sanitariamente. Conclusiones: Se evidenció que el agua se encuentra en un nivel de riesgo inviable sanitariamente, lo cual demuestra que el sistema de tratamiento es insuficiente para garantizar el suministro de agua apta para el consumo humano.
Introduction: Safe and easily accessible water is important to public health, whether it is used for drinking, domestic use, food production, or recreational purposes. Contaminated water and poor sanitation are linked to disease transmission. Objective: Evaluate the physical chemical and microbiological characteristics of the distribution network of the urban aqueduct of a municipality of Boyacá. Materials and methods: Cross-sectional descriptive quantitative study, water samples were taken at thirteen points, seven points agreed and materialized from the distribution network, one at the entrance of the plant, one in a deep well and in three births, where it is supplied the population. Phy-sical, chemical and microbiological analyzes were performed. Results: The untreated samples showed high levels of cobalt platinum units and turbidity. The free residual chlorine in two samples of treated water was below the established limits. Heterotrophic and Coliform microorganisms were detected in water samples obtained from sources of supply. At two points, Giardia cysts and Cryptosporidium oocysts were found. Of the Thirteen samples studied, three showed a Risk Index for sanitary water quality. Conclusions: It is evident that the water is at a level of sanitary unfeasible risk, which demonstrates that the treatment system is not sufficient to guarantee the supply of water suitable for human consumption.
Introdução: Água segura e de fácil acesso é importante para a saúde pública, seja ela usada para beber, uso doméstico, produção de alimentos ou para fins recreativos. A água contaminada e o sa-neamento precário estão ligados à transmissão de doenças. Objetivos: Avaliar as características físico-químicas e microbiológicas da rede de distribuição do aque-duto urbano de um município de Boyacá. Materiais e métodos: Estudo quantitativo descritivo transversal. Foram coletadas amostras de água em 13 pontos, 7 concertados e materializados da rede de distribuição, um na entrada da planta, dois poços e três nascentes, dos quais a população é abastecida. Foram realizadas analises físicas, químicas e microbiológicas em cada uma das amostras. Resultados: Nas amostras não tratadas havia concentrações altas de unidades platina, cobalto e turbidez. O cloro residual livre em duas amostras de água tratada estava abaixo dos limites estabele-cidos. Microrganismos heterótrofos e coliformes foram detectados em amostras de água obtidas de fontes de abastecimento. Os cistos de Giardia e os oocistos de Cryptosporidium foram encontrados em dois pontos. Das 13 amostras estudadas, três apresentaram um índice de risco para a qualidade não higiénica da água. Conclusões: Ficou evidente que a água está em um nível de risco sanitário inviável, o que mostra que o sistema de tratamento é insuficiente para garantir o abastecimento da água adequada para o consumo humano.
Assuntos
Controle da Qualidade da Água , Qualidade da Água , Cryptosporidium , Coliformes , GiardiaRESUMO
Resumo Objetivo Avaliar a qualidade microbiológica do leite humano pasteurizado proveniente de um Banco de Leite Humano do Estado de São Paulo. Métodos Estudo descritivo conduzido com 29 amostras de leite humano ordenhado pasteurizado (LHOP) obtidas entre julho de 2015 a março de 2016 por meio da avaliação dos registros da acidez titulável bem como da quantificação da microbiota heterotrófica (mesófilos, psicrófilos, termófilos), coliformes totais e termotolerantes, fungos filamentosos e leveduriformes e Staphylococcus spp. Realizou-se a avaliação dos parâmetros físico-químicos por meio do potencial hidrogeniônico-pH, teor energético-K e acidez Dornic-ºD. Análises estatísticas descritivas e bivariadas foram conduzidas. Resultados Evidenciou-se nas amostras a presença de psicrófilos (17,24%), termófilos (27,59%), mesófilos (55,17%), fungos filamentosos e leveduriformes (41,38%) e ausência de Staphylococcus spp. Detectou-se a presença de 82,76% de coliformes no teste presuntivo. Já no teste confirmativo VB constatou-se a presença de 54,16% de coliformes totais e no teste EC 33,33% de coliformes termotolerantes. Os valores de pH e de K não apresentaram oscilações, enquanto que, na expressão da acidez entre 3º a 15°D detectou-se crescimento microbiano. O microrganismo mesófilo, apresentou correlação positiva com variável da acidez Dornic (r=0.44;p=0.01). Conclusão A partir da avaliação da qualidade microbiológica das amostras de LHOP descartado e consideradas impróprias para consumo no referido BLH, especificamente com relação aos indicadores microbiológicos das condições de higiene, sugere que a inviabilidade das amostras possam estar associadas às boas práticas de manipulação do alimento.
Resumen Objetivo Evaluar la calidad microbiológica de la leche humana pasteurizada proveniente de un banco de leche humana del estado de São Paulo. Métodos Estudio descriptivo realizado con 29 muestras de leche humana ordeñada pasteurizada (LHOP) obtenidas entre julio de 2015 y marzo de 2016 por medio de la evaluación de los registros de acidez titulable, así como de la cuantificación de la microbiota heterótrofa (mesófilos, psicrófilos, termófilos), coliformes totales y termotolerantes, hongos filamentosos y levaduriformes y Staphylococcus spp. Se realizó la evaluación de los parámetros físico-químicos mediante el potencial de hidrógeno (pH), valor energético (K) y acidez Dornic-ºD. Se llevaron a cabo análisis descriptivos y bivariados. Resultados Se observó en las muestras la presencia de psicrófilos (17,24 %), termófilos (27,59 %), mesófilos (55,17 %), hongos filamentosos y levaduriformes (41,38 %) y ausencia de Staphylococcus spp. Se detectó la presencia del 82,76 % de coliformes en la prueba presuntiva. Por otro lado, en la prueba confirmativa VB se confirmó la presencia del 54,16 % de coliformes totales, y en la prueba EC se verificó el 33,33 % de coliformes termotolerantes. Los valores de pH y de K no presentaron oscilaciones, mientras que se detectó crecimiento microbiano en la expresión de la acidez entre 3 y 15°D. El microrganismo mesófilo presentó correlación positiva con variable de la acidez Dornic (r=0.44; p=0.01). Conclusión A partir de la evaluación de calidad microbiológica de las muestras de LHOP descartadas y consideradas inapropiadas para consumo en el BLH mencionado, especialmente respecto a los indicadores microbiológicos de las condiciones de higiene, se sugiere que la inviabilidad de las muestras pueda estar asociada con las buenas prácticas de manipulación del alimento.
Abstract Objective To assess the microbiological quality of pasteurized human milk from a Human Milk Bank in the State of São Paulo. Methods This is a descriptive study conducted with 29 pasteurized expressed human milk (PEHM) samples obtained between July 2015 and March 2016 by assessing titratable acidity records as well as quantifying heterotrophic microbiota (mesophiles, psychrophiles, thermophiles), total and thermotolerant coliforms, filamentous and yeast-like fungi and Staphylococcus spp. The physical-chemical parameters were assessed via hydrogen-pH potential, K-energy content and Dornic-ºD acidity. Descriptive and bivariate statistical analyzes were conducted. Results The presence of psychrophiles (17.24%), thermophiles (27.59%), mesophiles (55.17%), filamentous and yeast-like fungi (41.38%) and absence of Staphylococcus spp were evidenced in the sample. The presence of 82.76% of coliforms was detected in the presumptive test. In the confirmatory VB test, the presence of 54.16% of total coliforms was found and, in the EC test, we verified 33.33% of thermotolerant coliforms. The pH and K values did not show oscillations, whereas, in the expression of acidity between 3º and 15°D, microbial growth was detected. The mesophilic microorganism showed a positive correlation with the Dornic acidity variable (r=0.44; p=0.01). Conclusion Based on the microbiological quality assessment of the HMB samples discarded and considered unfit for consumption in the HMB, specifically regarding the microbiological indicators of hygiene conditions, it suggests that the infeasibility of the samples may be associated with good food handling practices.