Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 60
Filtrar
1.
BMC Surg ; 24(1): 103, 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38600472

RESUMO

BACKGROUND: There is no effective consensus on the choice of internal fixation method for the Masquelet technique in the treatment of large segmental bone defects of the distal tibia. Thus, the study aimed to investigate the outcomes of the Masquelet technique combined with double plate fixation in the treatment of large segmental bone defects. METHODS: This was a retrospective study involving 21 patients with large segmental bone defects of the distal tibia who were treated between June 2017 and June 2020. The length of bone defect ranged from 6.0 cm to 11 cm (mean, 8.19 cm). In the first stage of treatment, following complete debridement, a cement spacer was placed to induce membrane formation. In the second stage, double plate fixation and autologous cancellous bone grafting were employed for bone reconstruction. Each patient's full weight-bearing time, bone healing time, and Iowa ankle score were recorded, and the occurrence of any complications was noted. RESULTS: All patients were followed up for 16 to 26 months (mean, 19.48 months). The group mean full weight-bearing time and bone healing time after bone grafting were 2.41 (± 0.37) months and 6.29 (± 0.66) months, respectively. During the treatment, one patient had a wound infection on the medial side of the leg, so the medial plate was removed. The wound completely healed after debridement without any recurrence. After extraction of iliac bone for grafting, one patient had a severe iliac bone defect, which was managed by filling the gap with a cement spacer. Most patients reported mild pain in the left bone extraction area after surgery. The postoperative Iowa ankle score range was 84-94 (P < 0.05). In this cohort, 15 cases were rated as "excellent", and 6 cases as "good" on the Iowa ankle scoring system. CONCLUSION: The Masquelet technique combined with double plate fixation is a safe and effective method for the treatment of large segmental bone defects of the distal tibia.


Assuntos
Procedimentos de Cirurgia Plástica , Fraturas da Tíbia , Humanos , Tíbia/cirurgia , Estudos Retrospectivos , Extremidade Inferior/cirurgia , Fixação Interna de Fraturas , Transplante Ósseo/métodos , Resultado do Tratamento , Fraturas da Tíbia/cirurgia
2.
Arch Orthop Trauma Surg ; 144(2): 693-699, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37930359

RESUMO

INTRODUCTION: Humeral shaft fractures are common fractures of the diaphysis of the humerus. The aim of this study was to evaluate factors affecting the clinical outcomes of humeral nonunions surgically treated with open reduction and single- versus double-plate fixation with grafting. MATERIALS AND METHODS: A total of 31 patients with nonunion treated with single- or double-plate screw fixation with bone grafting were retrospectively analysed. The patients were divided into two groups according to the treatment method as Group 1 (single-plate, n = 14) and Group 2 (double-plate, n = 17). Data including demographic and clinical characteristics of the patients, initial and final treatment, type of nonunion and localisation, graft use, shortening, follow-up, time to union, Quick Disabilities of the Arm, Shoulder and Hand (Quick-DASH) scores, and patient-reported cosmetic outcomes were recorded. RESULTS: Of the patients, eight were males, and 23 were females, with a mean age of 47.6 ± 15.8 (range, 20-86) years. Initial treatment was conservative treatment (Sarmiento brace) in seven patients, plate fixation in 22 patients, and intramedullary nailing in two patients. The mean follow-up was 31.0 ± 16.9 months in Group 1 and 25.4 ± 15.6 months in Group 2. There was one nonunion in Group 1 and three in Group 2. There were no significant differences in the union rate and time to union (p = 0.378 and p = 0.262, respectively). The mean Quick-DASH scores and cosmetic results were similar between the groups (p = 0.423 and p = 0.165, respectively). Radial nerve palsy developed in three patients in Group 2, and all these patients recovered completely during follow-up. CONCLUSIONS: Although the double-plate fixation technique has similar clinical, radiological, and functional results to single-plate fixation, it is a more invasive and expensive technique with a longer operation time. Therefore, it should not be used as the first-line treatment option for all humeral shaft nonunion. Nevertheless, the double-plate technique may be preferred to achieve in cases requiring high stability, such as hypertrophic nonunion, osteopenia and comminuted fractures.


Assuntos
Fixação Intramedular de Fraturas , Fraturas não Consolidadas , Fraturas do Úmero , Masculino , Feminino , Humanos , Adulto , Pessoa de Meia-Idade , Diáfises/cirurgia , Estudos Retrospectivos , Fraturas não Consolidadas/cirurgia , Fraturas não Consolidadas/etiologia , Fixação Intramedular de Fraturas/métodos , Úmero , Fraturas do Úmero/cirurgia , Placas Ósseas , Resultado do Tratamento , Fixação Interna de Fraturas/métodos
3.
Eur J Orthop Surg Traumatol ; 34(5): 2767-2772, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38767681

RESUMO

BACKGROUND: Fixation with a distal lateral femoral plate is a standard approach in treating osteoporotic or comminuted supracondylar femur fractures. However, in clinical practice, this method may prove inadequate, necessitating the application of a plate on the medial side of the distal femur. The aim of this study is to perform a biomechanical evaluation of the newly manufactured anatomically locked plate applied to the distal medial femoral condyle. MATERIALS AND METHODS: The plate underwent 2 biomechanical tests by simulating an AO/OTA 33A3 type supracondylar fracture model on synthetic femur bones. The samples were divided into three groups. Fracture fixations were carried out on the medial side using the distal femur medial anatomical locking plate (DFMALP) in group A samples, on the lateral side using the distal femur lateral anatomical locking plate in group B samples, and on both sides in group C samples. RESULTS: In the axial compression test, stability was preserved 23% more in group C than in group B. During the cyclic axial compression test, total displacement was 21% less in group C than in group B. Group A was collapsed at early cycle degrees. CONCLUSION: In our study, it was observed that the application of DFMALP in conjunction with the lateral plate in AO/OTA 33A3 fragmented supracondylar femur fractures significantly enhanced biomechanical fracture stability. LEVEL OF EVIDENCE: This is a Level 2 prospective, randomized controlled study.


Assuntos
Placas Ósseas , Fraturas do Fêmur , Fixação Interna de Fraturas , Fraturas do Fêmur/cirurgia , Fraturas do Fêmur/fisiopatologia , Fenômenos Biomecânicos , Humanos , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/instrumentação , Fêmur/cirurgia , Teste de Materiais , Fraturas Cominutivas/cirurgia , Modelos Anatômicos
4.
Arch Orthop Trauma Surg ; 143(10): 6251-6259, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37460845

RESUMO

INTRODUCTION: Proximal ulna fractures with a large zone of comminution, such as in the context of Monteggia injuries, require mechanically strong osteosyntheses as they occur in regions with high physiological joint load. Consequently, implant failure and pseudarthrosis are critical and devastating complications, especially with the background of mainly young patients being affected. An effective solution could be provided by adding a small second plate 90° angulated to the standard dorsal plate in the area of non-union. Thus, this study investigates whether, from a biomechanical point of view, the use of such a mini or baby plate is worthwhile. MATERIALS AND METHODS: Comminuted fractures distal to the coronoid process, equivalent to Jupiter type IIb fractures, are generated on artificial Sawbones® of the ulna and stabilized using two different plate osteosyntheses: in the first group, a dorsal locking compression olecranon plate is used (LCP group). In the second group, a small, ulnar 5-hole olecranon plate is added as a baby plate in addition to the mother plate at the level of the fracture zone (MBP group). Dynamic biomechanical loading in degrees of flexion from 0° to 90° is carried out to determine yield load, stiffness, displacement, and changes in fracture gap width as well as bending of the dorsal plate. RESULTS: The "mother-baby-plate" osteosynthesis had a significantly higher yield load (p < 0.01) and stiffness (p = 0.01) than the LCP group. This correlates with the increased movement of the proximal fracture element during cyclic testing for the LCP group compared to the MBP group as measured by an optical metrology system. CONCLUSIONS: Here, we show evidence that the addition of a small plate to the standard plate is highly effective in increasing the biomechanical stability in severe fractures equivalent to Jupiter type IIb. As it hopefully minimizes complications like pseudarthrosis and implant failure and as the additional preparatory effort leading to compromised blood supply is regarded to be negligible, this justifies and highly advises the use of a mother-baby-plate system.


Assuntos
Fraturas Cominutivas , Pseudoartrose , Fraturas da Ulna , Feminino , Humanos , Mães , Fraturas da Ulna/cirurgia , Ulna , Placas Ósseas , Fixação Interna de Fraturas , Fraturas Cominutivas/cirurgia , Fenômenos Biomecânicos
5.
Arch Orthop Trauma Surg ; 143(10): 6209-6217, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37347253

RESUMO

INTRODUCTION: Varus collapse followed by osteosynthesis for distal femoral fractures with conventional implants has been well documented but is seldom mentioned in fractures managed with locking plates. The purpose of this study was to assess the incidence of varus collapse after treating complex supra-intercondylar fractures of the distal femur (AO type C3) using a Single Plate (SP) or Double Plate (DP) fixation technique. MATERIALS AND METHODS: We retrospectively reviewed 357 patients with distal femoral fractures who were treated at our hospital between 2006 and 2017. After excluding cases of infection, malignancy, periprosthetic fracture, revision surgery, pediatric fracture, and extra-articular fracture, 54 patients were included in the study. All demographic data and radiological and clinical outcomes were reviewed and analyzed. RESULTS: There were 54 patients enrolled into this study with age from 15 to 85 years old (mean 41.6, SD = 19.9), and 32 of them were open fractures (59%). The patients were further divided into either an SP (n = 15) or a DP group (n = 39). Demographics, including age, sex, injury severity score, and open fracture type, were all compatible between the two groups. The overall nonunion rate was 25.9% (n = 14; 6 from the SP and 8 from the DP group; p = 0.175). The varus collapse rate was 9.3% (n = 5; 4 from the SP and 1 from the DP group (p = 0.018). CONCLUSIONS: The varus collapse rate after osteosynthesis with a single lateral locking plate could be as high as 26.7% in AO type C3 fractures of the distal femur, which would be decreased to 2.6% by adding a medial buttress plate. Surgeons should consider DP fixation to avoid varus collapse in severely comminuted complete intra-articular fractures of the distal femur.


Assuntos
Fraturas Femorais Distais , Fraturas do Fêmur , Humanos , Criança , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Estudos Retrospectivos , Fraturas do Fêmur/cirurgia , Fixação Interna de Fraturas/métodos , Reoperação , Placas Ósseas , Fêmur , Resultado do Tratamento
6.
BMC Musculoskelet Disord ; 23(1): 521, 2022 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-35650582

RESUMO

OBJECTIVE: The application of double plating in olecranon fractures is becoming increasingly widespread. There is no research comparing this technique with traditional tension band wiring (TBW) and the single plate technique. The purpose of this study was to compare the efficacy of three fixation techniques in olecranon fractures. MATERIALS AND METHODS: From March 2016 to May 2020, we collected the clinical data of 95 patients with olecranon fractures who underwent surgical treatment. Thirty-five patients received TBW surgery (TBW Group), 32 patients received a 3.5 mm locking compression plate (LCP, 3.5 mm LCP Group), and 28 patients received double mini-locking plate treatment (DP Group). The operation time, fracture union time, time of return to work, range of motion (ROM), soft tissue stimulation to remove internal fixation, and patient-related functional results (the Weseley score, Mayo Elbow Performance Score [MEPS], and Disabilities of Arm, Shoulder and Hand Score [DASH]) were recorded. The clinical results and complications of the three internal fixation techniques were compared. RESULTS: The average follow-up time was 15.011.82 months (12-18 months). All patients' fractures healed by first intention. There were no statistically significant differences in the operation time, fracture union time, ROM, Weseley score, MEPS or DASH scores of the three groups of patients. The postoperative return time for patients in the TBW group was 10.002.15 weeks, the 3.5 mm LCP group was 9.561.93 weeks, and the DP group was 8.432.38 weeks (P = 0.014); 12 patients in the TBW group required removal of plant due to soft tissue stimulation, the 3.5 mm LCP group had 8 cases, and the DP group had 2 cases (P = 0.038). CONCLUSION: The postoperative clinical results and elbow joint function of patients with olecranon fractures fixed by tension band wiring, 3.5 mm LCP and double mini-locking plate are similar, which indicates that double-plate technology can be used as an alternative to the two groups of traditional techniques. In addition, double-plate technology also helps patients return to work earlier and has a lower incidence of soft tissue stimulation.


Assuntos
Fraturas Ósseas , Olécrano , Fraturas da Ulna , Fios Ortopédicos , Fixação Interna de Fraturas/efeitos adversos , Fixação Interna de Fraturas/métodos , Humanos , Olécrano/diagnóstico por imagem , Olécrano/cirurgia , Estudos Retrospectivos , Fraturas da Ulna/diagnóstico por imagem , Fraturas da Ulna/cirurgia
7.
Arch Orthop Trauma Surg ; 142(8): 1859-1864, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33844054

RESUMO

INTRODUCTION: The number of atraumatic stress fractures of the scapular spine associated with reverse shoulder arthroplasty is increasing. At present, there is no consensus regarding the optimal treatment strategy. Due to the already weakened bone, fractures of the scapular spine require a high fixation stability. Higher fixation strength may be achieved by double plating. The aim of this study was to evaluate the biomechanical principles of double plating in comparison to single plating for scapular spine fractures. METHODS: In this study, eight pairs (n = 16) of human shoulders were randomised pairwise into two groups. After an osteotomy at the level of the spinoglenoid notch, one side of each pair received fracture fixation with a single 3.5 LCP (Locking Compression Plate) plate. The contralateral scapular spine was fixed with a 3.5 LCP and an additional 2.7 LCP plate in 90-90 configuration. The biomechanical test protocol consisted of 700 cycles of dynamic loading and a load-to-failure test with a servohydraulic testing machine. Failure was defined as macroscopic catastrophic failure (screw cut-out, plate breakage). The focus was set on the results of specimens with osteoporotic bone quality. RESULTS: In specimens with an osteoporotic bone mineral density (BMD; n = 12), the mean failure load was significantly higher for the double plate group compared to single plating (471 N vs. 328 N; p = 0.029). Analysis of all specimens (n = 16) including four specimens without osteoporotic BMD revealed no significant differences regarding stiffness and failure load (p > 0.05). CONCLUSION: Double plating may provide higher fixation strength in osteoporotic bone in comparison to a single plate alone. This finding is of particular relevance for fixation of scapular spine fractures following reverse shoulder arthroplasty. LEVEL OF EVIDENCE: Controlled laboratory study.


Assuntos
Osteoporose , Fraturas por Osteoporose , Fraturas da Coluna Vertebral , Fenômenos Biomecânicos , Placas Ósseas , Cadáver , Fixação Interna de Fraturas/métodos , Humanos , Fraturas por Osteoporose/cirurgia
8.
Arch Orthop Trauma Surg ; 142(10): 2597-2609, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34097123

RESUMO

INTRODUCTION: Distal femur fractures are challenging injuries historically associated with high rates of nonunion and varus collapse with operative management. As a result, clinical and research interest in dual plating (DP) of distal femur fractures has seen a dramatic increase in recent years. The purpose of this study was to systematically review the literature regarding vascular anatomy and biomechanics of distal femur fractures treated with DP constructs. MATERIALS AND METHODS: A systematic literature review of two medical databases (PubMed & Scopus) was performed to identify peer-reviewed studies on the anatomy and biomechanics regarding DP of distal femur fractures. A total of 1,001 papers were evaluated and 14 papers met inclusion criteria (6 anatomy and 8 biomechanics). Methodological quality scores were used to assess quality and potential bias in the included studies. RESULTS: In the biomechanical studies, DP constructs demonstrated greater axial and rotational stiffness, as well as less displacement and fewer incidences of failure compared to all other constructs. Vascular studies showed that the femoral artery crosses the mid-shaft femur approximately 16.0-18.8 cm proximal to the adductor tubercle and it is located on average 16.6-31.1 mm from the femoral shaft at this location, suggesting that medial plate application can be achieved safely in the distal femur. The methodological quality of the included studies was good for biomechanical studies (Traa score 79.1; range 53-92.5) and excellent for anatomical studies (QUACs score 81.9; range 69.0-88.5). CONCLUSIONS: Existing biomechanics literature suggests that DP constructs are mechanically stronger than other constructs commonly used in the treatment of distal femur fractures. Furthermore, medial distal femoral anatomy allows for safe application of DP constructs, even in a minimally invasive fashion. Dual plating should be considered for patients with distal femur fractures that have risk factors for instability, varus collapse, or nonunion.


Assuntos
Fraturas do Fêmur , Fixação Interna de Fraturas , Fenômenos Biomecânicos , Placas Ósseas , Fraturas do Fêmur/patologia , Fraturas do Fêmur/cirurgia , Fixação Interna de Fraturas/métodos , Humanos
9.
Medicina (Kaunas) ; 58(11)2022 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-36422193

RESUMO

Background and Objectives: Arm wrestling is a simple and popular activity among young people that causes distal-third humeral fractures. However, injury to the young population may cause economic loss; therefore, they need to return to work as soon as possible. Accordingly, we aimed to compare radiological and functional outcomes of distal-third humeral fractures caused by arm wrestling treated with double and single plating. Materials and Methods: Thirty-four patients with distal-third humeral fractures caused by arm wrestling were treated between January 2015 and January 2021. They were separated into double- and single-plating groups and treated using a triceps-sparing approach. Regular follow-up was performed to evaluate elbow functionality, range of motion, bone union, and complications; the American Shoulder and Elbow Surgeons score was used for functional assessment. Results: Patients treated with single plating exhibited union rate, union time, and elbow range of motion similar to those of patients treated with double plating; however, they exhibited better pain and functional outcomes (American Shoulder and Elbow Surgeons score) at 2 weeks, 1 month, and 3 months postoperatively (84.50 ± 5.01 vs. 61.70 ± 12.53 at 2 weeks, 96.20 ± 2.63 vs. 84.25 ± 14.56 at 1 month, and 100.00 vs. 94.76 ± 9.71 at 3 months, p < 0.05). The two groups exhibited no significant differences after 1 year (100.00 vs. 98.54 ± 3.99, p < 0.13). The overall complication rate was significantly higher in patients treated with double plating than in those treated with single plating (18.75% vs. 5.56%). Radial nerve palsy was observed in patients in both groups. Conclusions: In patients with distal-third humeral fractures caused by arm wrestling, single plating provides a union rate and elbow range of motion similar to those of double plating, with significantly fewer complications and lower surgical time and blood loss with improved early functional outcomes.


Assuntos
Fraturas do Úmero , Luta Romana , Humanos , Estados Unidos , Adolescente , Fraturas do Úmero/cirurgia , Placas Ósseas , Estudos Retrospectivos , Braço
10.
Pak J Med Sci ; 38(4Part-II): 960-964, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35634606

RESUMO

Objectives: The purpose of this study was to investigate the clinical effect, knee function improvement and prognosis of double plate internal fixation and locking plate internal fixation in the treatment of tibial plateau fractures. Methods: Clinical data from 96 tibial plateau fracture patients treated at our hospital were analyzed retrospectively. Of these, 46 had been treated using locking plate internal fixation and 50 were treated with double T-shaped plate fixation. Clinically related indices, Hospital for Special Surgery (HSS) score of knee function, and ability of daily living (ADL) score were evaluated during postoperative follow-up. Results: No significant differences were observed in pre-operative patient characteristics in both groups. Healing time, time to weight-bearing, tibial plateau angle (TPA) and lateral posterior angle (PA) were all superior in the locking plate fixation group compared to the double plate fixation group. At three months post-operative visit, range of motion, knee function, flexion deformity, muscle strength, pain, and stability metrics were all superior in the locking plate fixation group compared to the double plate fixation group. ADL scores were also higher in the locking plate fixation group than in the double plate fixation group at three and six months follow-up. Conclusions: The clinical effect, knee function improvement and prognosis of locking plate internal fixation in the treatment of tibial plateau fractures are better than those of double plate fixation.

11.
BMC Musculoskelet Disord ; 22(1): 276, 2021 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-33714273

RESUMO

BACKGROUND: Internal fixation is recommended for treating Vancouver B1 periprosthetic femoral fractures. Although several fixation procedures have been developed with high fixation stability and union rates, long-term weight-bearing constructs are still lacking. Therefore, the aim of the present study was to evaluate the stability of a double-plate procedure using reversed contralateral locking compression-distal femoral plates for fixation of Vancouver B1 periprosthetic femoral fractures under full weight-bearing. METHODS: Single- and double-plate fixation procedures for locking compression-distal femoral plates were analysed under an axial load of 1,500 N by finite element analysis and biomechanical loading tests. A vertical loading test was performed to the prosthetic head, and the displacements and strains were calculated based on load-displacement and load-strain curves generated by the static compression tests. RESULTS: The finite element analysis revealed that double-plate fixation significantly reduced stress concentration at the lateral plate place on the fracture site. Under full weight-bearing, the maximum von Mises stress in the lateral plate was 268 MPa. On the other hand, the maximum stress in the single-plating method occurred at the defect level of the femur with a maximum stress value of 1,303 MPa. The principal strains of single- and double-plate fixation were 0.63 % and 0.058 %, respectively. Consistently, in the axial loading test, the strain values at a 1,500 N loading of the single- and double-plate fixation methods were 1,274.60 ± 11.53 and 317.33 ± 8.03 (× 10- 6), respectively. CONCLUSIONS: The present study suggests that dual-plate fixation with reversed locking compression-distal femoral plates may be an excellent treatment procedure for patients with Vancouver B1 fractures, allowing for full weight-bearing in the early postoperative period.


Assuntos
Fraturas do Fêmur , Fraturas Periprotéticas , Fenômenos Biomecânicos , Placas Ósseas , Fraturas do Fêmur/diagnóstico por imagem , Fraturas do Fêmur/cirurgia , Fêmur , Análise de Elementos Finitos , Fixação Interna de Fraturas , Humanos , Fraturas Periprotéticas/diagnóstico por imagem , Fraturas Periprotéticas/etiologia , Fraturas Periprotéticas/cirurgia
12.
J Shoulder Elbow Surg ; 30(12): 2852-2861, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34022364

RESUMO

BACKGROUND: Fractures of the proximal humerus are common. The most frequent surgical treatment option is open reduction and locking plate fixation. Multifragmentary fractures, including 3- and 4-part fractures, are especially challenging to treat because they correlate with an increased risk of fixation failure. In the past, several mechanisms of additional fixation were investigated, but none directly addressed the lesser tuberosity (LT). The goal of this study was to investigate the biomechanical impact of additional anterior fracture fixation in lateral locked plating (LLP) of 4-part proximal humeral fractures (PHFs). METHODS: Twenty-seven fresh frozen human shoulder specimens (mean age, 80 years) with intact rotator cuffs (RCs) were randomized into 4 groups: 3-part PHF with LLP and RC cerclage (n = 6); 4-part PHF with LLP and RC cerclage as standard of care (n = 7); 4-part PHF with LLP, RC cerclage, and 2 anterior 3.5-mm cortical screws (n = 7); and 4-part PHF with LLP, RC cerclage, and additional anterior one-third tubular plate (additional anterior plating [AAP], n = 7). Static load of the RC was simulated with weights. A force-controlled cyclic loading test was performed with a servo-hydraulic testing machine, followed by load-to-failure testing. An optical motion capture system recorded humeral head range of motion. RESULTS: LLP of a 4-part PHF showed more humeral head motion than LLP of a 3-part PHF without fracture of the LT (P < .001). Fixing the LT to the humeral head with two 3.5-mm screws significantly reduced humeral head motion compared with LLP with RC cerclage alone (P < .006). Using AAP significantly increased the construct stiffness compared with the standard of care (P = .03). CONCLUSION: LLP of a 4-part PHF is biomechanically less stable than LLP of a 3-part PHF without fracture of the LT. Additional screw fixation of the LT in 4-part PHFs improves stability compared with LLP alone. In case of metaphyseal comminution, AAP is favorable from a biomechanical perspective.


Assuntos
Fraturas do Ombro , Ombro , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Placas Ósseas , Parafusos Ósseos , Fixação Interna de Fraturas , Humanos , Cabeça do Úmero/diagnóstico por imagem , Cabeça do Úmero/cirurgia , Fraturas do Ombro/diagnóstico por imagem , Fraturas do Ombro/cirurgia
13.
J Shoulder Elbow Surg ; 30(7): 1519-1526, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33359398

RESUMO

BACKGROUND: In the treatment of unstable olecranon fractures, anatomically preshaped locking plates exhibit superior biomechanical results compared with tension band wiring. However, posterior plating (PP) still is accompanied by high rates of plate removal because of soft-tissue irritation and discomfort. Meanwhile, low-profile plates precontoured for collateral double plating (DP) are available and enable muscular soft-tissue coverage combined with angular-stable fixation. The goal of this study was to biomechanically compare PP with collateral DP for osteosynthesis of unstable osteoporotic fractures. METHODS: A comminuted displaced Mayo type IIB fracture was created in 8 osteoporotic pairs of fresh-frozen human cadaveric elbows. Pair-wise angular stable fixation was performed by either collateral DP or PP. Biomechanical testing was conducted as a pulling force to the triceps tendon in 90° of elbow flexion. Cyclical load changes between 10 and 300 N were applied at 4 Hz for 50,000 cycles. Afterward, the maximum load was raised by 0.02 N/cycle until construct failure, which was defined as displacement > 2 mm. Besides failure cycles and failure loads, modes of failure were analyzed. RESULTS: Following DP, a median endurance of 65,370 cycles (range, 2-83,121 cycles) was recorded, which showed no significant difference compared with PP, with 69,311 cycles (range, 150-81,938 cycles) (P = .263). Failure load showed comparable results as well, with 601 N (range, 300-949 N) after DP and 663 N (range, 300-933 N) after PP (P = .237). All PP constructs and 3 of 8 DP constructs failed by proximal fragment cutout, whereas 5 of 8 DP constructs failed by bony triceps avulsion. CONCLUSION: Angular-stable DP showed comparable biomechanical stability to PP in unstable osteoporotic olecranon fractures under high-cycle loading conditions. Failure due to bony triceps avulsion following DP requires further clinical and biomechanical investigation, for example, on suture augmentation or different screw configurations.


Assuntos
Olécrano , Fraturas por Osteoporose , Fenômenos Biomecânicos , Placas Ósseas , Cadáver , Fixação Interna de Fraturas , Humanos , Olécrano/cirurgia
14.
Arch Orthop Trauma Surg ; 141(2): 207-214, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33128096

RESUMO

INTRODUCTION: Very low periprosthetic distal femur fractures (PPDFFs) are rare injuries and often have a relatively high failure rate after single lateral locked plating. The double plating technique yields good outcomes in osteoporotic fractures of the distal femur. To date, there is limited information on double-locked plate fixation of very low PPDFFs. This study aimed to evaluate the outcomes and complications of surgically treated very low PPDFFs using double-locked plate fixation. MATERIALS AND METHODS: Between January 2013 and December 2018, sixty-one consecutive patients with PPDFFs have been conducted. Only Su type III PPDFFs with double-locked plate fixation through a lateral minimally invasive approach and a medial subvastus approach to the distal femur were analyzed. Patients were encouraged to perform straight leg raising exercises and active knee motion on the second postoperative day. Assisted weight bearing from the early postoperative days was supported, and full weight-bearing was allowed after healing the fracture site. All patients were evaluated according to the time to union, limb alignment, range of knee motion, Knee Society Score, and presence of complications. RESULTS: Twenty one patients (17 females and 4 males, mean age 76 years, range 56-90) were included in the study. There were 10 of 33-A1, 6 of 33-A2 and 5 of 33 A3 fractures, according to the AO classification. Of 21 patients, 20 achieved union at an average of 14 weeks postoperatively. Postoperative limb alignment was satisfactory in all cases, with an average mechanical distal lateral femur angle of 89° and average mechanical posterior distal femur angle of 86°. All patients recovered the knee joint motion similar to that of the contralateral side, and daily life pre-injury. The average knee and function scores were 94 and 89, respectively. There were one case of non-union and three cases of superficial wound infection, which resolved after intravenous antibiotic therapy. CONCLUSIONS: Double locked plating showed excellent radiographic and functional outcomes with few complications in patients with very low PPDFFs. Based on these promising results, we propose the consideration of double-locked plate fixation in the treatment of very low PPDFFs.


Assuntos
Placas Ósseas , Fraturas do Fêmur/cirurgia , Fixação Interna de Fraturas , Fraturas Periprotéticas/cirurgia , Idoso , Idoso de 80 Anos ou mais , Feminino , Fixação Interna de Fraturas/efeitos adversos , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/métodos , Humanos , Articulação do Joelho/cirurgia , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Resultado do Tratamento
15.
J Shoulder Elbow Surg ; 29(6): 1275-1281, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32284307

RESUMO

BACKGROUND: Because of poor soft-tissue coverage at the proximal ulna and prominent posteriorly positioned implants, hardware removal remains the most common reason for revision surgery of olecranon fractures that were operatively treated using plate osteosynthesis. We hypothesized that low-profile double-plate osteosynthesis would reduce the number of soft tissue-related hardware removals compared with single posterior plating whereas the functional results would be comparable. METHODS: This study retrospectively included patients who were treated with low-profile double-plate osteosynthesis or a posterior 2.7-/3.5-mm locking compression plate (LCP) for isolated olecranon fractures from 3 study centers. In addition to the implant removal rate, functional outcome measures (range of motion; Mayo Elbow Performance Score; Disabilities of the Arm, Shoulder and Hand score) were statistically compared. RESULTS: The study included 79 patients, with a mean follow-up period of 36 months (range, 24-77 months). Of these patients, 37 were treated with low-profile double-plate osteosynthesis and 42, with a 2.7-/3.5-mm LCP. The mean age was 57 years (range, 18-93 years). Range of motion after treatment with low-profile double-plate osteosynthesis and a 2.7-/3.5-mm LCP measured 129° (range, 80°-155°) and 139° (range, 100°-155°), respectively. The Mayo Elbow Performance Scores were 95 (range, 65-100) and 99 (range, 85-100), respectively (P = .028), and the Disabilities of the Arm, Shoulder and Hand scores were 5.0 (range, 0-49) and 4.6 (range, 0-28), respectively (P = .673). Hardware was removed in 32% and 50% of patients after treatment with double-plate osteosynthesis and a 2.7-/3.5-mm LCP, respectively (P = .11). Hardware removal owing to soft-tissue irritation was noted in 27% of patients after double-plate osteosynthesis and 38% after LCP treatment (P = .30). DISCUSSION: Low-profile double-plate osteosynthesis for treating olecranon fractures resulted in good clinical outcomes. However, the rate of hardware removal was not significantly reduced, and the functional results were comparable to those of common single-posterior plate osteosynthesis.


Assuntos
Placas Ósseas , Fixação Interna de Fraturas/instrumentação , Olécrano/lesões , Fraturas da Ulna/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Remoção de Dispositivo , Articulação do Cotovelo , Feminino , Fixação Interna de Fraturas/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Olécrano/cirurgia , Amplitude de Movimento Articular , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
16.
Int Orthop ; 42(4): 921-926, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29392385

RESUMO

PURPOSE: In distal humerus fractures, the goal is to achieve a functional range of motion of 30°-130° which is not always possible. The aims of the study were to evaluate the functional results after distal humerus fracture operation and to investigate the risk factors for stiffness. METHODS: Between 2005 and 2014, 75 patients with the mean age of 37.8 years (17-80) underwent open reduction and plate fixation for distal humerus fractures. Range of motion (ROM), Mayo elbow performance scores, and quick DASH scores were used for functional evaluation. Patients were divided into two groups according their ROM. Group 1 had > 100° of extension-flexion ROM and group 2 had < 100°. Older age (> 60), AO type C2-3 fracture, open fracture, longer injury-surgery interval, type of plating, and presence of olecranon osteotomy were investigated as risk factors for poor outcome. RESULTS: At a mean follow-up of 25 months (6-80), 40 patients were in group 1 and 35 patients were in group 2. Group 1 had significantly better functional scores than group 2. AO type C2 and C3 fracture (odds ratio (OR) 16.6, p < 0.0001) and injury-surgery interval longer than 7 days (OR 2.59, p 0.047) were found as significant risk factors for stiffness. CONCLUSIONS: Patients who had distal humerus fracture should be informed about the risk of elbow stiffness especially in AO type C2-C3 fractures and surgical treatment should be planned without any delay.


Assuntos
Placas Ósseas/efeitos adversos , Articulação do Cotovelo/cirurgia , Fixação Interna de Fraturas/efeitos adversos , Fraturas do Úmero/cirurgia , Complicações Pós-Operatórias/etiologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Fixação Interna de Fraturas/métodos , Humanos , Úmero/lesões , Úmero/cirurgia , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Amplitude de Movimento Articular/imunologia , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento , Adulto Jovem
17.
BMC Surg ; 16: 10, 2016 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-26968940

RESUMO

BACKGROUND: Complex proximal humerus fractures with metaphyseal comminution remain challenging regarding reduction and stability. In most fracture patterns the hard bone of the bicipital groove remains intact. In this case series, we describe a novel technique of hybrid double plate osteosynthesis of complex proximal humerus fractures with metaphyseal comminution. METHODS: In randomly chosen shoulder specimens and synthetic bones, pilot studies for evaluation of the feasibility of the technique were performed. Between 4/2010 and 1/2012 10 patients underwent hybrid double plate osteosynthesis. Seven patients (4 male, 3 female, mean age was 50 years (range 27-73)) were available for retrospective analysis. Based on plain radiographs (anterior-posterior and axial view), the fractures were classified according to the Orthopaedic Trauma Association classification (OTA) and by descriptive means (head-split variant (HS), diaphyseal extension or comminution (DE)). RESULTS: Follow-up radiographs demonstrated complete fracture healing in six patients and one incomplete avascular necrosis. None of the patients sustained loss of reduction. Three patients where reoperated. The medium, not adapted, Constant score was 80 Points (58-94). Patients subjective satisfaction was graded mean 3 (range: 0-6) in the visual analog scoring system (VAS). CONCLUSION: The technique of hybrid double plate osteosynthesis using the bicipital groove as anatomic landmark may re-establish shoulder function after complex proximal humerus fractures in two dimensions. Firstly the anatomy is restored due to a proper reduction based on intraoperative landmarks. Secondly additional support by the second plate may provide a higher stability in complex fractures with metaphyseal comminution.


Assuntos
Pontos de Referência Anatômicos , Placas Ósseas , Fixação Interna de Fraturas/métodos , Fraturas Cominutivas/cirurgia , Fraturas do Ombro/cirurgia , Adulto , Idoso , Feminino , Fixação Interna de Fraturas/instrumentação , Consolidação da Fratura , Humanos , Masculino , Pessoa de Meia-Idade , Amplitude de Movimento Articular , Reoperação , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
18.
EFORT Open Rev ; 9(6): 556-566, 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38828976

RESUMO

Objective: Through meta-analysis, this study aims to comprehensively evaluate the efficacy of single-plating and double-plating in the treatment of comminuted fractures of the distal femur. Methods: Computer searches of PubMed, Cochrane Library, Embase, China National Knowledge Infrastructure (CNKI), China Biology Medicine (CBM), VIP, and Wanfang digital journals were performed, and the timeframe for the searches was from the establishment of each database to July 2023 for each of the databases. Meta-analysis was performed using RevMan 5.4 software provided by the Cochrane Library, and the review process was registered in the PROSPERO database. Results: A total of ten studies were included for statistical analysis. One randomised controlled study and nine retrospective cohort studies with a total of 563 patients were included. The double-plate group was superior to the single-plate group in terms of knee mobility at 6 months postoperatively, overall postoperative complications, and the rate of healing of knee deformity. However, it increased the operation time and intraoperative bleeding, and the difference between the two groups was statistically significant (P < 0.05). There was no significant difference between the two groups in terms of excellent knee function rate, fracture healing time, plate fracture, postoperative infection, delayed fracture healing, and non-union (P ≥ 0.05). Conclusion: Double plate fixation for comminuted fractures of the distal femur can improve knee mobility at 6 months postoperatively, reduce overall postoperative complications, and decrease the incidence of malunion healing. However, it increases operative time and bleeding. Randomised studies are needed to provide strong evidence in the future.

19.
J Clin Orthop Trauma ; 53: 102439, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-39036509

RESUMO

Introduction: Distal fibula osteoporotic comminuted fractures are challenging to treat and are often treated with periarticular locking plates. This study examined the biomechanical difference between locked plating and dual non-locked one-third tubular plating. Methods: Using an osteoporotic Sawbones fibula model, simulated fracture were fixated with one-third tubular dual plating and locked periarticular plating. The samples were then torqued to failure and peak torque, stiffness, and displacement were recorded. Results: The peak torque of the dual plating group was found to be statistically higher than the periarticular locked plating group (0.841 Nm and 0.740 Nm respectively; p = 0.024). However overall stiffness calculated at each 10° increment of displacement was noted to have no significant difference between the two constructs. Conclusion: Dual non-locked plating of distal fibula osteoporotic comminuted fractures is biomechanically equivalent to locked periarticular plating.

20.
Behav Brain Res ; 441: 114269, 2023 03 12.
Artigo em Inglês | MEDLINE | ID: mdl-36574845

RESUMO

Cold intolerance is a debilitating effect of nerve injury, has a strong impact on the life of patients and no advisable treatment exists against it. Testosterone influences pain pathways and has analgesic effects. A recent study showed testosterone as being an agonist of TRPM8, the predominant ion channel that contributes to cold hypersensitivity after injury. We investigated the effect of testosterone on cold sensitivity after nerve injury. Specifically, using the double plate test (DPT) (thermo-neutral-plate: 31 ºC and cold-plate: 18 ºC) we determined the thermal preference of mice at different points during the study design consisting of: orchiectomy, tibial nerve transection (TNT) (30 days after orchiectomy), 15-days-repeated subcutaneous injections of testosterone enanthate (250 or 500 µg/kg/day) or vehicle (started 12 h after TNT surgery). Different parameters such as time spent on cold plates, distance traveled, animal speed on the cold- and thermo-neutral-plates were determined in naïve, sham and neuropathic animals. Neither orchiectomy nor sham TNT surgery generate effects on cold intolerance and animal activity while TNT surgery decreased the time spent on the cold-plate and the distance traveled during DPT. Testosterone administration reversed the effect of nerve injury, decreasing the cold hypersensitivity and increasing activity of TNT mice. However, the effect of testosterone on cold avoidance reduced with time and at 14 days after TNT surgery, a higher dose was needed to reverse the effect generated by nerve injury. This indicates that although testosterone administration has a positive effect on cold intolerance, it might not be suitable for prolongated treatment.


Assuntos
Síndromes Periódicas Associadas à Criopirina , Doenças do Sistema Nervoso Periférico , Camundongos , Animais , Dor , Nervo Tibial/lesões , Testosterona/farmacologia , Temperatura Baixa , Hiperalgesia/tratamento farmacológico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA