Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 125
Filtrar
1.
Eur Heart J ; 45(7): 510-518, 2024 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-37624879

RESUMO

BACKGROUND AND AIMS: Atrial fibrillation (AF) is a chronic progressive disorder. Persistent forms of AF are associated with increased rates of thromboembolism, heart failure, and death. Catheter ablation modifies the pathogenic mechanism of AF progression. No randomized studies have evaluated the impact of the ablation energy on progression to persistent atrial tachyarrhythmia. METHODS: Three hundred forty-six patients with drug-refractory paroxysmal AF were enrolled and randomly assigned to contact-force-guided RF ablation (CF-RF ablation, 115), 4 min cryoballoon ablation (CRYO-4, 115), or 2 min cryoballoon ablation (CRYO-2, 116). Implantable cardiac monitors placed at study entry were used for follow-up. The main outcome was the first episode of persistent atrial tachyarrhythmia. Secondary outcomes included atrial tachyarrhythmia recurrence and arrhythmia burden on the implantable monitor. RESULTS: At a median of 944.0 (interquartile range [IQR], 612.5-1104) days, 0 of 115 patients (0.0%) randomly assigned to CF-RF, 8 of 115 patients (7.0%) assigned to CRYO-4, and 5 of 116 patients (4.3%) assigned to CRYO-2 experienced an episode of persistent atrial tachyarrhythmia (P = .03). A documented recurrence of any atrial tachyarrhythmia ≥30 s occurred in 56.5%, 53.9%, and 62.9% of those randomized to CF-RF, CRYO-4, and CRYO-2, respectively; P = .65. Compared with that of the pre-ablation monitoring period, AF burden was reduced by a median of 99.5% (IQR 94.0%, 100.0%) with CF-RF, 99.9% (IQR 93.3%-100.0%) with CRYO-4, and 99.1%% (IQR 87.0%-100.0%) with CRYO-2 (P = .38). CONCLUSIONS: Catheter ablation of paroxysmal AF using radiofrequency energy was associated with fewer patients developing persistent AF on follow-up.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Fibrilação Atrial/cirurgia , Criocirurgia/efeitos adversos , Resultado do Tratamento , Ablação por Cateter/efeitos adversos , Taquicardia , Recidiva , Veias Pulmonares/cirurgia
2.
Pflugers Arch ; 476(7): 1145-1154, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38703193

RESUMO

Arrhythmia detection is essential when assessing the safety of novel drugs and therapies in preclinical studies. Many short-term arrhythmia monitoring methods exist, including non-invasive ECG and Holter. However, there are no reliable, long-term, non-invasive, or minimally invasive methods for cardiac arrhythmia follow-up in large animals that allows free movement with littermates. A long follow-up time is needed when estimating the impact of long-lasting drugs or therapies, such as gene therapy. We evaluated the feasibility and performance of insertable cardiac monitors (ICMs) in pigs for minimally invasive, long-term monitoring of cardiac arrhythmias that allows free movement and species-specific behavior. Multiple implantation sites were tested to assess signal quality. ICMs recognized reliably many different arrhythmias but failed to detect single extrasystoles. They also over-diagnosed T-waves, resulting in oversensing. Muscle activity and natural startles of the animals caused noise, leading to a heterogeneous signal requiring post-recording evaluation. In spite of these shortcomings, the ICMs showed to be very useful for minimally invasive long-term monitoring of cardiac rhythm in pigs.


Assuntos
Arritmias Cardíacas , Animais , Suínos , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Eletrocardiografia Ambulatorial/instrumentação , Eletrocardiografia Ambulatorial/métodos , Eletrocardiografia/métodos , Eletrocardiografia/instrumentação , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Monitorização Fisiológica/veterinária
3.
J Cardiovasc Electrophysiol ; 35(2): 341-345, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38164063

RESUMO

INTRODUCTION: The increasing use of insertable cardiac monitors (ICMs) for long-term continuous arrhythmia monitoring creates a high volume of transmissions and a significant workload for clinics. The ability to remotely reprogram device alert settings without in-office patient visits was recently introduced, but its impact on clinic workflow compared to the previous ICM iteration is unknown. METHODS: The aim of this real-world study was to evaluate the impact of device reprogramming capabilities on ICM alert burden and on clinic workflow. Deidentified data was obtained from US patients and a total of 19 525 receiving a LINQ II were propensity score-matched with 19 525 implanted with LINQ TruRhythm (TR) ICM based on age and reason for monitoring. RESULTS: After reprogramming, ICM alerts reduced by 20.5% (p < .001). Compared with patients monitored with LINQ TR, patients with LINQ II had their device reprogrammed sooner after implant and more frequently during follow-up. Adoption of remote programming was projected to lead to an annual total clinic time savings of 211 h per 100 ICM patients managed. CONCLUSION: These data suggest that utilization of ICM alert reprogramming has increased with remote capabilities, which may reduce clinic and patient burden for ICM follow-up and free clinician time for other valuable patient care activities.


Assuntos
Arritmias Cardíacas , Eletrocardiografia Ambulatorial , Humanos , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Doença do Sistema de Condução Cardíaco
4.
BMC Neurol ; 23(1): 115, 2023 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-36944929

RESUMO

BACKGROUND: Cryptogenic stroke is a heterogeneous condition, with a wide spectrum of possible underlying causes for which the optimal secondary prevention may differ substantially. Attempting a correct etiological diagnosis to reduce the stroke recurrence should be the fundamental goal of modern stroke management. METHODS: Prospective observational international multicenter study of cryptogenic stroke and cryptogenic transient ischemic attack (TIA) patients clinically monitored for 12 months to assign the underlying etiology. For atrial fibrillation (AF) detection continuous cardiac rhythm monitoring with insertable cardiac monitor (Reveal LINQ, Medtronic) was performed. The 12-month follow-up data for 250 of 259 initially included NOR-FIB patients were available for analysis. RESULTS: After 12 months follow-up probable stroke causes were revealed in 43% patients, while 57% still remained cryptogenic. AF and atrial flutter was most prevalent (29%). In 14% patients other possible causes were revealed (small vessel disease, large-artery atherosclerosis, hypercoagulable states, other cardioembolism). Patients remaining cryptogenic were younger (p < 0.001), had lower CHA2DS2-VASc score (p < 0.001) on admission, and lower NIHSS score (p = 0.031) and mRS (p = 0.016) at discharge. Smoking was more prevalent in patients that were still cryptogenic (p = 0.014), while dyslipidaemia was less prevalent (p = 0.044). Stroke recurrence rate was higher in the cryptogenic group compared to the group where the etiology was revealed, 7.7% vs. 2.8%, (p = 0.091). CONCLUSION: Cryptogenic stroke often indicates the inability to identify the cause in the acute phase and should be considered as a working diagnosis until efforts of diagnostic work up succeed in identifying a specific underlying etiology. Timeframe of 6-12-month follow-up may be considered as optimal. TRIAL REGISTRATION: ClinicalTrials.gov Identifier NCT02937077, EudraCT 2018-002298-23.


Assuntos
Fibrilação Atrial , Ataque Isquêmico Transitório , AVC Isquêmico , Acidente Vascular Cerebral , Humanos , Fibrilação Atrial/complicações , Fibrilação Atrial/epidemiologia , Ataque Isquêmico Transitório/complicações , Ataque Isquêmico Transitório/epidemiologia , Ataque Isquêmico Transitório/diagnóstico , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/diagnóstico , AVC Isquêmico/complicações , Causalidade , Eletrocardiografia Ambulatorial/efeitos adversos
5.
Europace ; 26(1)2023 12 28.
Artigo em Inglês | MEDLINE | ID: mdl-38170474

RESUMO

AIMS: The increasing use of insertable cardiac monitors (ICM) produces a high rate of false positive (FP) diagnoses. Their verification results in a high workload for caregivers. We evaluated the performance of an artificial intelligence (AI)-based ILR-ECG Analyzer™ (ILR-ECG-A). This machine-learning algorithm reclassifies ICM-transmitted events to minimize the rate of FP diagnoses, while preserving device sensitivity. METHODS AND RESULTS: We selected 546 recipients of ICM followed by the Implicity™ monitoring platform. To avoid clusterization, a single episode per ICM abnormal diagnosis (e.g. asystole, bradycardia, atrial tachycardia (AT)/atrial fibrillation (AF), ventricular tachycardia, artefact) was selected per patient, and analyzed by the ILR-ECG-A, applying the same diagnoses as the ICM. All episodes were reviewed by an adjudication committee (AC) and the results were compared. Among 879 episodes classified as abnormal by the ICM, 80 (9.1%) were adjudicated as 'Artefacts', 283 (32.2%) as FP, and 516 (58.7%) as 'abnormal' by the AC. The algorithm reclassified 215 of the 283 FP as normal (76.0%), and confirmed 509 of the 516 episodes as abnormal (98.6%). Seven undiagnosed false negatives were adjudicated as AT or non-specific abnormality. The overall diagnostic specificity was 76.0% and the sensitivity was 98.6%. CONCLUSION: The new AI-based ILR-ECG-A lowered the rate of FP ICM diagnoses significantly while retaining a > 98% sensitivity. This will likely alleviate considerably the clinical burden represented by the review of ICM events.


Assuntos
Inteligência Artificial , Fibrilação Atrial , Humanos , Eletrocardiografia Ambulatorial/métodos , Fibrilação Atrial/diagnóstico , Eletrocardiografia , Algoritmos
6.
Heart Vessels ; 38(5): 731-739, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36443457

RESUMO

Syncope prognosis is related to both its etiology and comorbidities, with cardiac syncope (CS) having higher risks for mortality and cardiovascular events than syncope of non-cardiac causes. Although a novel insertable cardiac monitor (ICM) is an effective diagnostic tool for unexplained syncope, decision regarding ICM implantation with a high pre-test likelihood of CS should contribute to economic cost reduction and avoidance of unnecessary complications. This study aimed to investigate clinical factors associated with CS after ICM implantation in patients with unexplained syncope. This retrospective observational study included 31 consecutive patients with ICM implantation for syncope between September 2016 and August 2021. The initial examinations for syncope included a detailed history, physical examination, blood tests, 12-lead electrocardiograms, and transthoracic echocardiography. Of the 31 patients, 13 (41.9%) experienced recurrent CS during follow-up (676 ± 469 days). Among several clinical factors, syncope-related minor injuries (p = 0.017) and higher brain natriuretic peptide (BNP; p = 0.043) levels were significantly associated with CS. Moreover, multivariable analysis showed that both syncope-related minor injuries (odds ratio, 11.2; 95% confidence interval, 1.4-88.4; p = 0.022) and BNP higher than 64.0 pg/mL (odds ratio, 7.0; 95% confidence interval, 1.1-44.2; p = 0.038) were independent predictors of CS after ICM implantation. In conclusion, a history of minor injury secondary to syncope and higher BNP levels were independent CS predictors in patients receiving ICM for syncope. These results emphasized the utility of ICM implantation early in the diagnostic journey of patients presenting with CS predictors requiring specific treatments.


Assuntos
Eletrocardiografia , Síncope , Humanos , Prognóstico , Estudos Retrospectivos , Síncope/diagnóstico , Síncope/epidemiologia , Síncope/etiologia , Eletrocardiografia Ambulatorial
7.
Ann Noninvasive Electrocardiol ; 28(2): e13043, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36718801

RESUMO

BACKGROUND: Percutaneous catheter ablation (CA) to achieve pulmonary vein isolation is an effective treatment for drug-refractory paroxysmal and persistent atrial fibrillation (AF). However, recurrence rates after a single AF ablation procedure remain elevated. Conventional management after CA ablation has mostly been based on clinical AF recurrence. However, continuous recordings with insertable cardiac monitors (ICMs) and patient-triggered mobile app transmissions post-CA can now be used to detect early recurrences of subclinical AF (SCAF). We hypothesize that early intervention following CA based on personalized ICM data can prevent the substrate progression that promotes the onset and maintenance of atrial arrhythmias. METHODS: This is a randomized, double-blind (to SCAF data), single-tertiary center clinical trial in which 120 patients with drug-refractory paroxysmal or persistent AF are planned to undergo CA with an ICM. Randomization will be to an intervention arm (n = 60) consisting of ICM-guided early intervention based on SCAF and patient-triggered mobile app transmissions versus a control arm (n = 60) consisting of a standard intervention protocol based on clinical AF recurrence validated by the ICM. Primary endpoint is AF burden, which will be assessed from ICMs at 15 months post-AF ablation. Secondary endpoints include healthcare utilization, functional capacity, and quality of life. CONCLUSION: We believe that ICM-guided early intervention will provide a novel, personalized approach to post-AF ablation management that will result in a significant reduction in AF burden, healthcare utilization, and improvements in functional capacity and quality of life.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Qualidade de Vida , Eletrocardiografia , Resultado do Tratamento , Protocolos Clínicos , Ablação por Cateter/métodos , Recidiva , Ensaios Clínicos Controlados Aleatórios como Assunto
8.
J Electrocardiol ; 77: 29-36, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36577318

RESUMO

BACKGROUND: Atrial Fibrillation (AF) is a major risk factor for stroke, which is the second leading cause of death worldwide. It remains uncertain whether insertable cardiac monitors (ICMs) enhance the ability to recognize AF over external cardiac monitoring in patients who have experienced a stroke. AIM: We conducted a systematic review and meta-analysis to determine whether ICM devices are more effective than external cardiac monitoring for the detection of AF in stroke patients. METHODS: We included studies that reported an AF detection rate in stroke patients with a follow-up of at least 12 months. We analyzed the data of 1233 patients from 3 randomized control trials (RCTs). RESULTS: When compared to external cardiac monitoring, ICM devices (Medtronic Reveal LINQ and Reveal XT) showed a significantly higher detection rate of AF (RR = 5.04, 95% CI = 2.93-8.68; p < 0.05; ARR = 10.47%, NNT = 10). The ICM arm had significantly higher usage of oral anticoagulants (OAC) as compared to the control arm. (RR = 2.76, 95% CI = 1.89-4.02, p < 0.05). Additionally, ICM usage was associated with a higher incidence of mild to moderate adverse events (RR = 10.52, 95% CI =1.35-82.14; p = 0.02) and a higher number of severe adverse events as compared to the control arm (RR = 7.61, 95% CI = 1.36-42.51; p = 0.02). CONCLUSION: ICM devices are associated with better detection rates of AF and higher usage of OAC as compared to external cardiac monitoring in post-stroke patients. However, ICM insertion is associated with a higher incidence of mild/moderate and severe adverse effects.


Assuntos
Fibrilação Atrial , Acidente Vascular Cerebral , Humanos , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Eletrocardiografia Ambulatorial , Eletrocardiografia , Acidente Vascular Cerebral/diagnóstico , Fatores de Risco , Anticoagulantes
9.
Cardiol Young ; 33(12): 2518-2520, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36970856

RESUMO

Insertable cardiac monitors are minimally invasive devices designed for implantation in the chest wall of patients to record heart rhythms and relate them to symptoms over prolonged periods. The Jot Dx™ (Abbott Laboratories, Abbott Park, IL, USA) is the latest Food and Drug Administration-cleared insertable cardiac monitor that is Bluetooth™ enabled allowing for near-immediate transmission of data from patients to physicians. We report on the first paediatric patient, in a patient weighing 11.7 kg, to undergo a modified, vertical, parasternal implantation of a Jot Dx™.


Assuntos
Fibrilação Atrial , Humanos , Criança , Fibrilação Atrial/diagnóstico , Eletrocardiografia Ambulatorial
10.
J Cardiovasc Electrophysiol ; 33(4): 741-750, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35118767

RESUMO

BACKGROUND: Insertable cardiac monitors (ICMs) are essential for ambulatory arrhythmia diagnosis. However, definitive diagnoses still require time-consuming, manual adjudication of electrograms (EGMs). OBJECTIVE: To evaluate the clinical impact of selecting only key EGMs for review. METHODS: Retrospective analyses of randomly selected Abbott Confirm Rx™ devices with ≥90 days of remote transmission history were performed, with each EGM adjudicated as true or false positive (TP, FP). For each device, up to 3 "key EGMs" per arrhythmia type per day were prioritized for review based on ventricular rate and episode duration. The reduction in EGMs and TP days (patient-days with at least one TP EGM), and any diagnostic delay (from the first TP), were calculated versus reviewing all EGMs. RESULTS: In 1000 ICMs over a median duration of 8.1 months, at least one atrial fibrillation (AF), tachycardia, bradycardia, or pause EGM was transmitted by 424, 343, 190, and 325 devices, respectively, with a total of 95 716 EGMs. Approximately 90% of episodes were contributed by 25% of patients. Key EGM selection reduced EGM review burden by 43%, 66%, 77%, and 50% (55% overall), while reducing TP days by 0.8%, 2.1%, 0.2%, and 0.0%, respectively. Despite reviewing fewer EGMs, 99% of devices with a TP EGM were ultimately diagnosed on the same day versus reviewing all EGMs. CONCLUSION: Key EGM selection reduced the EGM review substantially with no delay-to-diagnosis in 99% of patients exhibiting true arrhythmias. Implementing these rules in the Abbott patient care network may accelerate clinical workflow without compromising diagnostic timelines.


Assuntos
Fibrilação Atrial , Diagnóstico Tardio , Fibrilação Atrial/diagnóstico , Bradicardia/diagnóstico , Humanos , Estudos Retrospectivos , Taquicardia/diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA