Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Magn Reson Med ; 79(1): 224-233, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28321915

RESUMO

PURPOSE: Noncontrast 4D-MR-angiography (MRA) using arterial spin labeling (ASL) is beneficial because high spatial and temporal resolution can be achieved. However, ASL requires acquisition of labeled and control images for each phase. The purpose of this study is to present a new accelerated 4D-MRA approach that requires only a single control acquisition, achieving similar image quality in approximately half the scan time. METHODS: In a multi-phase Look-Locker sequence, the first phase was used as the control image and the labeling pulse was applied before the second phase. By acquiring the control and labeled images within a single Look-Locker cycle, 4D-MRA was generated in nearly half the scan time of conventional ASL. However, this approach potentially could be more sensitive to off-resonance and magnetization transfer (MT) effects. To counter this, careful optimizations of the labeling pulse were performed by Bloch simulations. In in-vivo studies arterial visualization was compared between the new and conventional ASL approaches. RESULTS: Optimization of the labeling pulse successfully minimized off-resonance effects. Qualitative assessment showed that residual MT effects did not degrade visualization of the peripheral arteries. CONCLUSION: This study demonstrated that the proposed approach achieved similar image quality as conventional ASL-MRA approaches in just over half the scan time. Magn Reson Med 79:224-233, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Angiografia/métodos , Interpretação de Imagem Assistida por Computador/métodos , Angiografia por Ressonância Magnética/métodos , Aceleração , Adulto , Angiografia Digital , Artérias , Simulação por Computador , Feminino , Voluntários Saudáveis , Humanos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Ondas de Rádio , Marcadores de Spin , Fatores de Tempo , Adulto Jovem
2.
NMR Biomed ; 30(2)2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28052565

RESUMO

Sickle cell anemia (SCA) is a genetic disorder resulting in reduced oxygen carrying capacity and elevated stroke risk. Pseudo-continuous arterial spin labeling (pCASL) measures of cerebral blood flow (CBF) may have relevance for stroke risk assessment; however, the effects of elevated flow velocity and reduced bolus arrival time (BAT) on CBF quantification in SCA patients have not been thoroughly characterized, and pCASL model parameters used in healthy adults are often applied to patients with SCA. Here, cervical arterial flow velocities and pCASL labeling efficiencies were computed in adults with SCA (n = 19) and age- and race-matched controls without sickle trait (n = 7) using pCASL in sequence with phase contrast MR angiography (MRA). Controls (n = 7) and a subgroup of patients (n = 8) also underwent multi-post-labeling-delay pCASL for BAT assessment. Mean flow velocities were elevated in SCA adults (velocity = 28.3 ± 4.1 cm/s) compared with controls (velocity = 24.5 ± 3.8 cm/s), and mean pCASL labeling efficiency (α) was reduced in SCA adults (α = 0.72) relative to controls (α = 0.91). In patients, mean whole-brain CBF from phase contrast MRA was 91.8 ± 18.1 ml/100 g/min, while mean pCASL CBF when assuming a constant labeling efficiency of 0.86 was 75.2 ± 17.3 ml/100 g/min (p < 0.01), resulting in a mean absolute quantification error of 23% when a labeling efficiency appropriate for controls was assumed. This difference cannot be accounted for by BAT (whole-brain BAT: control, 1.13 ± 0.06 s; SCA, 1.02 ± 0.09 s) or tissue T1 variation. In conclusion, BAT variation influences pCASL quantification less than elevated cervical arterial velocity and labeling efficiency variation in SCA adults; thus, a lower labeling efficiency (α = 0.72) or subject-specific labeling efficiency should be incorporated for SCA patients.


Assuntos
Anemia Falciforme/diagnóstico por imagem , Anemia Falciforme/fisiopatologia , Velocidade do Fluxo Sanguíneo , Angiografia Cerebral/métodos , Circulação Cerebrovascular , Aumento da Imagem/métodos , Angiografia por Ressonância Magnética/métodos , Adulto , Meios de Contraste , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Marcadores de Spin
3.
AJR Am J Roentgenol ; 204(6): W701-6, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26001259

RESUMO

OBJECTIVE: Cervical contrast-enhanced MR angiography (MRA) has proven accurate and superior to noncontrast alternatives. We proposed the systematic investigation of dose reduction in contrast-enhanced MRA, hypothesizing heightened tolerance at 3 T vs 1.5 T. Quantitative and qualitative features were compared between full-dose and 50%-reduced dose examinations at 1.5 T and 3 T. MATERIALS AND METHODS: One hundred eight cervical contrast-enhanced MRA examinations were reviewed for qualitative and quantitative (signal-to-noise ratio [SNR] and contrast-to-noise ratio [CNR]) features across four dose-field strength combinations: 1.5 T, 0.05 mmol/kg; 3 T, 0.05 mmol/kg; 1.5 T, 0.1 mmol/kg; and 3 T, 0.1 mmol/kg. Quantitative features were evaluated among the following segments: aortic arch, common carotid arteries, common carotid bifurcations, and cervical internal carotid arteries. A qualitative visual rating scale was applied for the same segments as well as to the vertebral arteries along their proximal (V1), intraforaminal (V2), and distal extraforaminal (V3) courses. Significant between-group differences were reported at p < 0.05. RESULTS: Qualitatively good arteriography was observed in all segments for all protocols. No significant qualitative differences between protocols were noted throughout evaluation of the anterior cervical circulation. Significant qualitative differences were observed only for V2 and V3 segments at half-dose 1.5-T compared with the remaining protocols (p < 0.05). No significant quantitative differences were present between full-dose and dose-reduced 3-T MRA in any segment. At 1.5 T, significant decrement in SNR and CNR at half-dose was present only within the cervical internal carotid artery. CONCLUSION: Dose reduction in cervical contrast-enhanced MRA is feasible at 3 T without significant compromise in arteriographic quality in most segments. Particularly at 3 T, arteriography is quantitatively and qualitatively robust and may be advisable in high-risk patients.


Assuntos
Artefatos , Transtornos Cerebrovasculares/patologia , Gadolínio/administração & dosagem , Interpretação de Imagem Assistida por Computador/métodos , Angiografia por Ressonância Magnética/métodos , Pescoço/irrigação sanguínea , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste/administração & dosagem , Relação Dose-Resposta a Droga , Relação Dose-Resposta à Radiação , Feminino , Humanos , Aumento da Imagem/métodos , Campos Magnéticos , Masculino , Pessoa de Meia-Idade , Pescoço/patologia , Segurança do Paciente , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Adulto Jovem
4.
AJR Am J Roentgenol ; 205(3): W366-73, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26102308

RESUMO

OBJECTIVE: Ferumoxytol is increasingly reported as an alternative to gadolinium-based contrast agents for MR angiography (MRA), particularly for patients with renal failure. This article summarizes more than 3 years of clinical experience with ferumoxytol-enhanced MRA for a range of indications and anatomic regions. CONCLUSION: Ferumoxytol-enhanced MRA has many advantages including that it is safe for patients with renal failure and provides a lengthy plateau of vascular signal as a blood pool agent that allows longer navigated MRA sequences.


Assuntos
Meios de Contraste , Óxido Ferroso-Férrico , Angiografia por Ressonância Magnética , Doenças Vasculares/diagnóstico , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Aumento da Imagem , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
5.
Magn Reson Imaging Clin N Am ; 31(3): 475-491, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37414473

RESUMO

Pulmonary MR angiography (MRA) is a useful alternative to computed tomographic angiography (CTA) for the study of the pulmonary vasculature. For pulmonary hypertension and partial anomalous pulmonary venous return, a cardiac MR imaging and the pulmonary MRA are useful for flow quantification and planning treatment. For the diagnosis of pulmonary embolism (PE), MRA-PE has been shown to have non-inferior outcomes at 6 months when compared with CTA-PE. Over the last 15 years, pulmonary MRA has become a routine and reliable examination for the workup of pulmonary hypertension and the primary diagnosis of PE at the University of Wisconsin.


Assuntos
Hipertensão Pulmonar , Embolia Pulmonar , Humanos , Imageamento por Ressonância Magnética/métodos , Angiografia por Ressonância Magnética/métodos , Meios de Contraste , Embolia Pulmonar/diagnóstico
6.
J Am Coll Radiol ; 20(11S): S513-S520, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-38040468

RESUMO

Abdominal aortic aneurysm (AAA) is defined as abnormal dilation of the infrarenal abdominal aortic diameter to 3.0 cm or greater. The natural history of AAA consists of progressive expansion and potential rupture. Although most AAAs are clinically silent, a pulsatile abdominal mass identified on physical examination may indicate the presence of an AAA. When an AAA is suspected, an imaging study is essential to confirm the diagnosis. This document reviews the relative appropriateness of various imaging procedures for the initial evaluation of suspected AAA. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision process support the systematic analysis of the medical literature from peer reviewed journals. Established methodology principles such as Grading of Recommendations Assessment, Development, and Evaluation or GRADE are adapted to evaluate the evidence. The RAND/UCLA Appropriateness Method User Manual provides the methodology to determine the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where peer reviewed literature is lacking or equivocal, experts may be the primary evidentiary source available to formulate a recommendation.


Assuntos
Aneurisma da Aorta Abdominal , Humanos , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Diagnóstico por Imagem/métodos , Medicina Baseada em Evidências , Exame Físico , Sociedades Médicas , Estados Unidos
7.
Int J Cardiovasc Imaging ; 39(5): 1023-1030, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36781568

RESUMO

To evaluate Quiescent Interval Slice Selective (QISS) balanced steady-state free precession (bSSFP) and QISS fast low-angle shot (FLASH) sequences for non-contrast Magnetic Resonance Angiography (MRA) of iliac arteries regarding image quality and diagnostic confidence in order to establish these sequences in daily clinical practice. A prospective study of healthy subjects (n = 10) was performed. All subjects underwent the QISS MRI protocol with bSSFP und FLASH sequences. Vessel contrast-to-background ratio (VCBR) were measured in pre-defined vessel segments. Image quality and diagnostic confidence was assessed using a Likert scale (five-point scale). Inter-reader agreement was determined using Cohen's kappa coefficient (κ). Ten healthy subjects (median age 29 years, IQR: 26.25 to 30 years) were included in this prospective study. Median MR examination time was 2:05 min (IQR 1:58 to 2:16) for QISS bSSFP and 4:11 min (IQR 3:57 to 4:32) for QISS FLASH. Both sequences revealed good VCBR in all examined vessel segments. VCBR (muscle tissue) were marginally higher for FLASH sequences (e.g., 0.82 vs. 0.78 in the right femoral artery, p = 0.035*), while bSSFP sequence showed significantly higher VCBR (fat tissue) in the majority of examined arterials vessels (e.g., 0.78 vs. 0.62 in right femoral artery, p = 0.001*). The image quality and diagnostic confidence of both sequences were rated as good to excellent. Moderate to good inter-reader agreement was found. QISS MRA using bSSFP and FLASH sequences are diagnostic for visualization of iliac arterial vasculature. The QISS bSSFP sequence might offer advantages due to the markedly shorter exam time and superior visualization of smaller vessels. The QISS FLASH sequence seems to be a robust alternative for non-contrast MRA since it is less sensitive to magnetic field inhomogeneities.


Assuntos
Artérias , Angiografia por Ressonância Magnética , Humanos , Adulto , Estudos Prospectivos , Valor Preditivo dos Testes , Angiografia por Ressonância Magnética/métodos , Reprodutibilidade dos Testes , Meios de Contraste
8.
J Am Coll Radiol ; 19(11S): S364-S373, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36436963

RESUMO

Arterial claudication is a common manifestation of peripheral artery disease. This document focuses on necessary imaging before revascularization for claudication. Appropriate use of ultrasound, invasive arteriography, MR angiography, and CT angiography are discussed. The ACR Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision process support the systematic analysis of the medical literature from peer reviewed journals. Established methodology principles such as Grading of Recommendations Assessment, Development, and Evaluation or GRADE are adapted to evaluate the evidence. The RAND/UCLA Appropriateness Method User Manual provides the methodology to determine the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where peer reviewed literature is lacking or equivocal, experts may be the primary evidentiary source available to formulate a recommendation.


Assuntos
Doença Arterial Periférica , Sociedades Médicas , Humanos , Medicina Baseada em Evidências , Claudicação Intermitente/diagnóstico por imagem , Angiografia , Doença Arterial Periférica/diagnóstico por imagem , Extremidade Inferior/diagnóstico por imagem , Extremidade Inferior/irrigação sanguínea
9.
Cardiovasc Diagn Ther ; 9(Suppl 1): S152-S173, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31559161

RESUMO

Imaging is needed for diagnosis, treatment planning, and follow-up of patients with pathologies affecting upper extremity vasculature. With growth and evolution of imaging modalities [especially CT angiography (CTA) and MR angiography (MRA)], there is need to recognize the advantages and disadvantages of various modalities and obtain the best possible imaging diagnostic test. Understanding various limitations and pitfalls as well as the best practices to minimize and manage these pitfalls is very important for the diagnosis. This article reviews the upper extremity arterial vascular anatomy, discusses the CTA and MRA imaging, various pitfalls, and challenges and discuss imaging manifestations of upper extremity arterial pathologies.

10.
Magn Reson Imaging ; 60: 164-172, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31075419

RESUMO

PURPOSE: After an endovascular aortic aneurysm repair (EVAR), a follow-up at 1, 6 and every 12 months is recommended for remainder of the patient's life. The diagnostic standard methods for diagnosing endoleaks and visualization of aneurysms in EVAR-patients are: invasive digital subtraction angiography (DSA), contrast enhanced (CE) computed tomographic angiography (CE-CTA), and magnetic resonance angiography (CE-MRA). These techniques, however, require the use of iodine- or gadolinium-based contrast agents with rare, but possibly life threatening side effects such as renal impairment, thyrotoxicosis and allergic reactions, nephrogenic systemic fibrosis, and cerebral gadolinium deposition. The aim of this prospective study was to compare a non-contrast-enhanced MRI protocol (consist of four MRI methods) with DSA and CE-CTA for visualization and quantification of endovascular aortic prosthesis, their endoleaks and aneurysms. MATERIAL AND METHODS: Eight patients (mean age 76.8 ±â€¯4.9 years, 63% male), whose thoracic, abdominal, or iliac aneurysms were treated with different endovascular prosthesis and suffered from type I-V endoleaks, were examined on a 1.5 Tesla MR system. Quiescent-interval slice selective MR angiography (QISS-MRA), 4-dimensional (4D)-flow MRI, T1- and T2-mapping, as well as DSA and CE-CTA were used for the visualization and quantification of endoprosthesis, endoleaks, and aneurysms in these patients. RESULTS: QISS-MRA provided good visualization of endoleaks and comparable quantification of aneurysm size with respect to CE-CTA and DSA. The 4D-flow MRI provided additional information about the wall shear stress, which could not be determined using DSA. In contrast to CE-CTA, T1- and T2-mapping provided detailed information about heterogeneous areas within an aneurysm sac. CONCLUSIONS: Compared to DSA and CE-CTA, the proposed MRI methods provide improved anatomical and functional information for various types of endoprostheses and endoleaks. In addition, hemodynamic parameters of the aorta and information on the content of aneurysm sac are provided as well. Within the frame of personalized medicine, the personalized diagnosis enabled by this non-CE MRI protocol is the foundation for a personalized and successful treatment.


Assuntos
Aneurisma/diagnóstico por imagem , Angiografia Digital , Prótese Vascular , Endoleak/diagnóstico por imagem , Angiografia por Ressonância Magnética , Idoso , Idoso de 80 Anos ou mais , Aorta , Aneurisma da Aorta Abdominal , Meios de Contraste , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Estudos Prospectivos , Próteses e Implantes , Tomografia Computadorizada por Raios X
11.
Magn Reson Imaging ; 49: 25-31, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29217492

RESUMO

Hemorrhage and lipid deposits contribute to instability in atherosclerotic plaques. Unstable carotid artery plaques can lead to cerebral ischemic events. While MRI studies have shown the ability to identify plaque components, the identification of hemorrhage and lipids has proven to be problematic. The purpose of this study was to quantitatively evaluate the potential of the MRI fat/water separation method known as iterative decomposition of water and fat with echo asymmetry and least squares estimation (IDEAL) to complement and improve existing methods for the identification of hemorrhage and lipids in carotid artery plaques. Fifteen asymptomatic subjects with 50-79% stenosis of at least one carotid artery were enrolled. Hemorrhage and lipid components within carotid plaques were identified using previously published criteria based on the multiple contrast-weighted (MCW) method (3D Time-of-Flight (3D-TOF), T1-Weighted (T1W) and T2-Weighted (T2W)). The hemorrhage:muscle, lipid:muscle and intra-plaque lipid:hemorrhage signal intensity ratios (SIR) and contrast to noise ratios (CNR) were measured on MCW and compared to IDEAL black-blood images. No differences were found between any of the MCW methods for any of the SIRs measured. The IDEAL Fat images had higher lipid:muscle and lipid/hemorrhage SIRs (p<0.001) compared to IDEAL Water and all MCW image sequence types. The mean values of IDEAL Fat hemorrhage:muscle SIR and CNR were nearly unity (1.1±0.6) and nearly zero (0.1±1.1), respectively. The IDEAL Water imaging was not significantly different than any of the MCW methods for any of the SIRs or for the hemorrhage:muscle CNR of 3D-TOF, while its CNRs were significantly higher than IDEAL Fat lipid:muscle (p<0.05) and lipid:hemorrhage (p<0.001) and all MCW methods (p<0.001). The addition of IDEAL Water and Fat imaging to the MCW method shows potential to improve the identification of hemorrhage and lipid structures in carotid artery plaques.


Assuntos
Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/metabolismo , Hemorragia/diagnóstico por imagem , Lipídeos/análise , Imageamento por Ressonância Magnética/métodos , Placa Aterosclerótica/diagnóstico por imagem , Idoso , Artérias Carótidas/diagnóstico por imagem , Artérias Carótidas/metabolismo , Estenose das Carótidas/complicações , Feminino , Hemorragia/complicações , Humanos , Análise dos Mínimos Quadrados , Masculino , Pessoa de Meia-Idade , Placa Aterosclerótica/complicações , Placa Aterosclerótica/metabolismo
12.
J Neuroimaging ; 27(6): 607-612, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28574627

RESUMO

BACKGROUND: Spontaneous cervical artery dissection (sCAD) is an important etiology of juvenile stroke. The gold standard for the diagnosis of sCAD is convential angiography. However, magnetic resonance imaging (MRI)/MR angiography (MRA) and computed tomography (CT)/CT angiography (CTA) are frequently used alternatives. New developments such as multislice CT/CTA have enabled routine acquisition of thinner sections with rapid imaging times. The goal of this study was to compare the capability of recent developed 128-slice CT/CTA to MRI/MRA to detect radiologic features of sCAD. METHODS: Retrospective review of patients with suspected sCAD (n = 188) in a database of our Stroke center (2008-2014), who underwent CT/CTA and MRI/MRA on initial clinical work-up. A control group of 26 patients was added. All Images were evaluated concerning specific and sensitive radiological features for dissection by two experienced neuroradiologists. Imaging features were compared between the two modalities. RESULTS: Forty patients with 43 dissected arteries received both modalities (29 internal carotid arteries [ICAs] and 14 vertebral arteries [VAs]). All CADs were identified in CT/CTA and MRI/MRA. The features intimal flap, stenosis, and lumen irregularity appeared in both modalities. One high-grade stenosis was identified by CT/CTA that was expected occluded on MRI/MRA. Two MRI/MRA-confirmed pseudoaneurysms were missed by CT/CTA. None of the controls evidenced specific imaging signs for dissection. CONCLUSIONS: CT/CTA is a reliable and better available alternative to MRI/MRA for diagnosis of sCAD. CT/CTA should be used to complement MRI/MRA in cases where MRI/MRA suggests occlusion.


Assuntos
Dissecção Aórtica/diagnóstico por imagem , Artéria Carótida Interna/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Artéria Vertebral/diagnóstico por imagem , Adulto , Bases de Dados Factuais , Feminino , Humanos , Angiografia por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
13.
Artigo em Inglês | WPRIM | ID: wpr-194482

RESUMO

PURPOSE: Susceptibility vessel sign (SVS) on gradient echo image, which is caused by MR signal loss due to arterial thrombosis, has been reported in acute middle cerebral artery (MCA) infarction. However, the reported sensitivity and diagnostic accuracy of SVS have been variable. Susceptibility-weighted imaging (SWI) is a newly developed MR sequence. Recent studies have found that SWI may be useful in the field of cerebrovascular diseases, especially for detecting the presence of prominent veins, microbleeds and the SVS. The purpose of this study was to evaluate the diagnostic values of SWI for the detection of hyperacute MCA occlusion. MATERIALS AND METHODS: Sixty-nine patients (37 males, 32 females; 46-89 years old [mean, 69.1]) with acute stroke involving the MCA territory underwent MR imaging within 6 hours after the symptom onset. MR examination included T2, FLAIR (fluid-attenuated inversion recovery), DWI, SWI, PWI (perfusion-weighted imaging), contrast-enhanced MR angiography (MRA) and contrast-enhanced T1. Of these patients, 28 patients also underwent digital subtraction angiography (DSA) within 2 hours after MR examination. Presence or absence of SVS on SWI was assessed without knowledge of clinical, DSA and other MR imaging findings. RESULTS: On MRA or DSA, 34 patients (49.3%) showed MCA occlusion. Of these patients, SVS was detected in 30 (88.2%) on SWI. The sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy of SWI were 88.2%, 97.1%, 96.8%, 89.5% and 92.8%, respectively. CONCLUSION: SWI was sensitive, specific and accurate for the detection of hyperacute MCA occlusion.


Assuntos
Feminino , Humanos , Masculino , Angiografia , Angiografia Digital , Transtornos Cerebrovasculares , Infarto , Imageamento por Ressonância Magnética , Artéria Cerebral Média , Sensibilidade e Especificidade , Acidente Vascular Cerebral , Trombose , Veias
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA