Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 969
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Proc Natl Acad Sci U S A ; 120(38): e2303765120, 2023 Sep 19.
Artigo em Inglês | MEDLINE | ID: mdl-37695901

RESUMO

This work reports that synchronization of Mott material-based nanoscale coupled spiking oscillators can be drastically different from that in conventional harmonic oscillators. We investigated the synchronization of spiking nanooscillators mediated by thermal interactions due to the close physical proximity of the devices. Controlling the driving voltage enables in-phase 1:1 and 2:1 integer synchronization modes between neighboring oscillators. Transition between these two integer modes occurs through an unusual stochastic synchronization regime instead of the loss of spiking coherence. In the stochastic synchronization regime, random length spiking sequences belonging to the 1:1 and 2:1 integer modes are intermixed. The occurrence of this stochasticity is an important factor that must be taken into account in the design of large-scale spiking networks for hardware-level implementation of novel computational paradigms such as neuromorphic and stochastic computing.

2.
Small ; : e2309955, 2024 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-38415899

RESUMO

Designing lanthanide luminescence lifetime sensors in the second near-infrared (NIR-II) window holds great potentials for physiological studies. However, the single lifetime signal is confined to one or two orders of magnitude of signal variation, which limits the sensitivity of lifetime probes. In this study, a lifetime cascade system, i.e., ZGO:Mn, Eu-DNA-1/TCPP-PEI70K @Yb-AptEpCAM , with a variety of signals (τm , τn , τµ , τm /τn and τm /τµ ) is constructed for exosome identification using time-domain multiplexing. The sensitized ligand TCPP acts as both target-modulated switch and a bridge for connecting long lifetime ZGO:Mn, Eu-DNA-1 emitter to lanthanide Yb3+ . This drives successive dual-path energy transfer and forms two D(donor) -A(acceptor) pairs. The lifetime variation is dominantly modulated by arranging TCPP as energy intermediate relay to covert milliseconds to nanoseconds to microseconds. It enables a broad lifetime range of six orders of magnitude. The presence of exosome specifically recognizes aptamers on TCPP-PEI70K @Yb-AptEpCAM to impede D-A pairs and reverse multiplexed response signals of the lifetime cascade system. The ratio lifetime signals τm /τn and τm /τµ achieve prominent exosome quantification and exosome type differentiation attributed to signal amplification. The cascade system relying on lifetime criteria can realize precise quantization and provide an effective strategy for subsequent physiological study.

3.
Small ; 20(21): e2309338, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38102097

RESUMO

Attaining elevated thermal conductivity in organic materials stands as a coveted objective, particularly within electronic packaging, thermal interface materials, and organic matrix heat exchangers. These applications have reignited interest in researching thermally conductive organic materials. The understanding of thermal transport mechanisms in these organic materials is currently constrained. This study concentrates on N, N'-dioctyl-3,4,9,10-perylenedicarboximide (PTCDI-C8), an organic conjugated crystal. A correlation between elevated thermal conductivity and augmented Young's modulus is substantiated through meticulous experimentation. Achievement via employing the physical vapor transport method, capitalizing on the robust C═C covalent linkages running through the organic matrix chain, bolstered by π-π stacking and noncovalent affiliations that intertwine the chains. The coexistence of these dynamic interactions, alongside the perpendicular alignment of PTCDI-C8 molecules, is confirmed through structural analysis. PTCDI-C8 thin film exhibits an out-of-plane thermal conductivity of 3.1 ± 0.1 W m-1 K-1, as determined by time-domain thermoreflectance. This outpaces conventional organic materials by an order of magnitude. Nanoindentation tests and molecular dynamics simulations elucidate how molecular orientation and intermolecular forces within PTCDI-C8 molecules drive the film's high Young's modulus, contributing to its elevated thermal conductivity. This study's progress offers theoretical guidance for designing high thermal conductivity organic materials, expanding their applications and performance potential.

4.
NMR Biomed ; 37(4): e5081, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38113906

RESUMO

Very short chemical exchange saturation transfer (CEST) pulses are beneficial in cardiac continuous wave (cw) CEST MRI, especially in small animals because of their rapid heartbeat; however, they result in signal modulations caused by Rabi oscillations. Therefore, we implemented two different filter techniques, DOwnsampling by SEparation of CEST spectrum into two parts (DOSE) and time domain (TD)-based filtering, to correct for these signal corruptions, allowing a reliable quantification of glucose-weighted CEST (glucoCEST) MRI contrast. In our study, cw CEST measurements were performed on a 9.4-T small animal BioSpec system using CEST pulses in the range of 10 to 200 ms. Experimental dependencies of Rabi oscillations on key MRI parameters were validated by Bloch-McConnell (BM) simulations. Filter efficiency was explored in a glucose concentration series as well as in the myocardium of healthy mice (n = 8), and glucoCEST contrast was subsequently quantified. The experimental results showed that the impact of Rabi oscillations on CEST spectra increased with decreasing CEST pulse length, optimized B0 homogeneity, and shorter T2 relaxation time, in accordance with results from BM simulations. Both investigated filter techniques reduced these signal modulations significantly, with DOSE filtering preserving the amplitude and TD filtering the spectral information of CEST data more accurately. Upon filter application, a significant decrease in glucoCEST contrast in the myocardium of healthy mice was observed after glucose infusion (pTD = 0.0079, pDOSE = 0.0044). To conclude, this study offers comprehensive experimental insights into Rabi oscillations within CEST MRI data along with methodological considerations that could be further advanced into a robust and precise cardiac cw CEST protocol by integrating DOSE and TD filtering into the standard CEST analysis pipeline.


Assuntos
Algoritmos , Imageamento por Ressonância Magnética , Camundongos , Animais , Simulação por Computador , Imageamento por Ressonância Magnética/métodos , Concentração de Íons de Hidrogênio , Glucose
5.
Nanotechnology ; 35(17)2024 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-38266304

RESUMO

Metal halide perovskite nanowires (PrvNWs) have recently emerged as an interesting path for nanostructured solar cells. Here, we model the absorption of light in PrvNW arrays for varying diameter and length of the PrvNWs and period for the array by solving the Maxwell equations. For long enough bare PrvNW arrays, we find that the optimum diameter is fixed to that which places the absorption peak from the HE11waveguide mode in the PrvNWs to the vicinity of the bandgap wavelength. In contrast, when we include a transparent conductive oxide (TCO) top contact layer, the optimum diameter shifts to a larger value by 100 nm. The origin of this shift is traced to a reduced reflection at the interface between the TCO layer and the PrvNW array when the PrvNW's diameter is larger. Overall, we find that 1500 nm long PrvNWs can reach 90% of the broadband absorption potential, making this system of high interest for photovoltaics.

6.
Chem Pharm Bull (Tokyo) ; 72(7): 676-680, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39019598

RESUMO

The purpose of this study was to continuously monitor the pseudopolymorphic transition from anhydrate to monohydrate by measuring the NMR relaxation using time-domain NMR (TD-NMR). Taking advantage of the simplicity of the low-field NMR instrument configuration, which is an advantage of TD-NMR, the NMR instrument was connected to a humidity controller to monitor the pseudopolymorphic transition. First, ezetimibe (EZT) monohydrate was prepared from its anhydrate using a saturated salt solution method, and T1 relaxation of EZT monohydrate and anhydrate was measured without a humidity controller. The T1 relaxation results confirmed that EZT anhydrate and monohydrate could be distinguished using T1 relaxation measurement. Next, continuous monitoring was conducted by TD-NMR and connected to a humidity controller. Anhydrous EZT was placed in an NMR glass tube and the T1 relaxation measurement was repeated while maintaining the humidity on the side entering the NMR tube at 80% relative humidity. The T1 relaxation became gradually faster from the initial to middle monitoring phases. The final T1 relaxation was then recovered fully and these T1 relaxation times were the same as the T1 relaxation of EZT monohydrate. This study successfully monitored the pseudopolymorphic transition from EZT anhydrate to monohydrate via NMR relaxation.


Assuntos
Ezetimiba , Espectroscopia de Ressonância Magnética , Ezetimiba/química , Estrutura Molecular
7.
Opt Mater (Amst) ; 1472024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38283740

RESUMO

The metal-ligand complex tris(2,2'-bipyridine)ruthenium(II) chloride (Ru probe) displays a broad emission spectrum ranging from 540 to 730 nm. The emission spectra of Ru probe were measured when placed on top of a one-dimensional photonic crystal (1DPC), which supports both Bloch surface wave (BSW) and internal modes for wavelengths below 640 nm and only internal modes above 640 nm. The S-polarized emission spectra, with the electric vector parallel to the 1DPC surface, were found to be strongly dependent on the observation angle through the coupling prism. Also, the usual single broad-emission spectrum of Ru probe on glass was converted into two or more narrow-band-spectrum on the 1DPC, with emission band maxima dependent on the observation angle. The two S-polarized emission band peaks for Ru probe were found to be consistent with coupling to the BSW and first internal mode (IM1) of the 1DPC. The same spectral shifts and changes in emission maxima were observed by using Kretschmann and reverse Kretschmann illuminations. As the coupling requires the emitter to be in proximity with the photonic structure, we calculated near- and far-field distributions of a dipole directly located on the 1DPC surface. Finite-Difference Time-Domain (FDTD) simulations were performed to confirm fluorophore coupling to the BSW and internal modes (IMs). Both the measured and simulated results showed that IM coupled emission is significant. Coupling to the IM mode occurred at longer wavelengths where the 1DPC did not support a BSW. These results demonstrate that a simple Bragg grating, without a BSW mode, can be used for detection of surface-bound fluorophores.

8.
Sensors (Basel) ; 24(6)2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38544069

RESUMO

In this paper, we report our use of a hardware encoder-based synchronization method for a fast terahertz time-domain spectroscopy raster scanner built with the commercially available TeraFlash Smart platform. We describe the principles of our method, including our incorporation of synchronization signals from various devices included in the scanner. We also describe its implementation in a microcontroller with a dedicated counter. By such means, a fast scanning mode was obtained, which was 35 times faster than a traditional step-by-step approach. To validate the proposed synchronization method, we carried out measurements using the USAF 1951 resolution test and a fiberglass plate with a set of intentionally introduced defects. Our results confirmed that the TDS scanner with the developed synchronization method was able to capture high-quality images with resolutions as high as those obtained using traditional step-by-step scanning, but with significantly reduced scanning times.

9.
Sensors (Basel) ; 24(7)2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38610584

RESUMO

An efficient path integral (PI) model for the accurate analysis of curved dielectric structures on coarse grids via the two-dimensional nonstandard finite-difference time-domain (NS-FDTD) technique is introduced in this paper. In contrast to previous PI implementations of the perfectly electric conductor case, which accommodates orthogonal cells in the vicinity of curved surfaces, the novel PI model employs the occupation ratio of dielectrics in the necessary cells, providing thus a straightforward and instructive means to treat an assortment of practical applications. For its verification, the reflection from a flat plate and the scattering from a cylinder using the PI model are investigated. Results indicate that the featured methodology can enable the reliable and precise modeling of arbitrarily shaped dielectrics in the NS-FDTD algorithm on coarse grids.

10.
Sensors (Basel) ; 24(13)2024 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-39000822

RESUMO

By applying a high projection rate, the binary defocusing technique can dramatically increase 3D imaging speed. However, existing methods are sensitive to the varied defocusing degree, and have limited depth of field (DoF). To this end, a time-domain Gaussian fitting method is proposed in this paper. The concept of a time-domain Gaussian curve is firstly put forward, and the procedure of determining projector coordinates with a time-domain Gaussian curve is illustrated in detail. The neural network technique is applied to rapidly compute peak positions of time-domain Gaussian curves. Relying on the computing power of the neural network, the proposed method can reduce the computing time greatly. The binary defocusing technique can be combined with the neural network, and fast 3D profilometry with a large depth of field is achieved. Moreover, because the time-domain Gaussian curve is extracted from individual image pixel, it will not deform according to a complex surface, so the proposed method is also suitable for measuring a complex surface. It is demonstrated by the experiment results that our proposed method can extends the system DoF by five times, and both the data acquisition time and computing time can be reduced to less than 35 ms.

11.
Sensors (Basel) ; 24(6)2024 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-38544023

RESUMO

The Jones matrix and the Mueller matrix of the coherent Rayleigh backscattering (RB) in single-mode fibers (SMFs) have been derived recently. It has been shown that both matrices depict two polarization effects-birefringence and polarization-dependent loss (PDL)-although the SMF under investigation is purely birefringent, having no PDL. In this paper, we aim to perform a theoretical analysis of both matrices using polar decomposition. The derived sub-Jones/Mueller matrices, representing birefringence and PDL, respectively, can be used to investigate the polarization properties of the coherent RB. As an application of the theoretical results, we use the derived formulas to investigate the polarization properties of the optical signals in phase-sensitive optical time-domain reflectometry (φ-OTDR). For the first time, to our knowledge, by using the derived birefringence-Jones matrix, the common optical phase of the optical signal in φ-OTDR is obtained as the function of the forward phase and birefringence distributions. By using the derived PDL-Mueller matrix, the optical intensity of the optical signal in φ-OTDR is obtained as the function of the forward phase and birefringence distributions as well as the input state of polarization (SOP). Further theoretical predictions show that, in φ-OTDR, the common optical phase depends on only the local birefringence in the first half of the fiber section, which is occupied by the sensing pulse, irrelevant of the input SOP. However, the intensity of the φ-OTDR signal is not a local parameter, which depends on the input SOP and the birefringence distribution along the entire fiber section before the optical pulse. Moreover, the PDL measured in φ-OTDR is theoretically proven to be a local parameter, which is determined by the local birefringence and local optical phase distributions.

12.
Sensors (Basel) ; 24(11)2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38894072

RESUMO

The large amount of sampled data in coherent phase-sensitive optical time-domain reflectometry (Φ-OTDR) brings heavy data transmission, processing, and storage burdens. By using the comparator combined with undersampling, we achieve simultaneous reduction of sampling rate and sampling resolution in hardware, thus greatly decreasing the sampled data volume. But this way will inevitably cause the deterioration of detection signal-to-noise ratio (SNR) due to the quantization noise's dramatic increase. To address this problem, denoising the demodulated phase signals using compressed sensing, which exploits the sparsity of spectrally sparse vibration, is proposed, thereby effectively enhancing the detection SNR. In experiments, the comparator with a sampling parameter of 62.5 MS/s and 1 bit successfully captures the 80 MHz beat signal, where the sampled data volume per second is only 7.45 MB. Then, when the piezoelectric transducer's driving voltage is 1 Vpp, 300 mVpp, and 100 mVpp respectively, the SNRs of the reconstructed 200 Hz sinusoidal signals are respectively enhanced by 23.7 dB, 26.1 dB, and 28.7 dB by using compressed sensing. Moreover, multi-frequency vibrations can also be accurately reconstructed with a high SNR. Therefore, the proposed technique can effectively enhance the system's performance while greatly reducing its hardware burden.

13.
Sensors (Basel) ; 24(7)2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38610393

RESUMO

Real-time source localization is crucial for high-end automation and artificial intelligence (AI) products. However, a low signal-to-noise ratio (SNR) and limited processing time can reduce localization accuracy. This work proposes a new architecture for a time-domain feedback-based beamformer that meets real-time processing demands. The main objective of this design is to locate reflective sources by estimating their direction of arrival (DOA) and signal range. Incorporating a feedback mechanism in this architecture refines localization precision, a unique aspect of this approach. We conducted an in-depth analysis to compare the effectiveness of time-domain feedback beamforming against conventional time-domain methods, highlighting their benefits and limitations. Our evaluation of the proposed architecture, based on critical performance indicators such as peak-to-sidelobe ratio, mainlobe width, and directivity factor, demonstrates its ability to improve beamformer effectiveness significantly.

14.
Sensors (Basel) ; 24(8)2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38676270

RESUMO

Induction motors (IM) play a fundamental role in the industrial sector because they are robust, efficient, and low-cost machines. Changes in the environment, installation errors, or modifications to working conditions can generate faults in induction motors. The trend on IM fault detection is focused on the design techniques and sensors capable of evaluating multiple faults with various signals using non-invasive analysis. The methodology is based on processing electric current signals by applying the short-time Fourier transform (STFT). Additionally, the computation of the mean and standard deviation of infrared thermograms is proposed as main indicators. The proposed system combines both parameters by means of Support Vector Machine and k-nearest-neighbor classifiers. The development of the diagnostic system was done with digital hardware implementations using a Xilinx PYNQ Z2 card that integrates an FPGA with a microprocessor, thus taking advantage of the acquisition and processing of digital signals and images in hardware. The proposed method has proved to be effective for the classification of healthy (HLT), misalignment (MAMT), unbalance (UNB), damaged bearing (BDF), and broken rotor bar (BRB) faults with an accuracy close to 99%.

15.
Sensors (Basel) ; 24(5)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38475143

RESUMO

Overlapped Time Domain Multiplexing (OvTDM) is a high-rate transmission technology that employs the idea of superposition coded modulation (SCM) scheme for signal generation, aiming to achieve maximum channel capacity sharing. Meanwhile, it is also widely considered as a promising technique toward physical layer security. As a main drawback of such system, a high peak-to-average power ratio (PAPR) issue in this system, arising from multi-layer superposition, can be addressed through intentional clipping. However, the detection at the receiver side is vulnerable to nonlinear distortion caused by clipping, which can degrade the performance. To mitigate this distortion, this paper proposed an iterative scheme for estimating and partially canceling clipping distortion at the receiver. We managed to mitigate the impact of clipping noise as much as possible and minimize the cost of optimizing PAPR, thereby improving the transmission performance of OvTDM in the context of amplitude clipping.

16.
Sensors (Basel) ; 24(10)2024 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-38793909

RESUMO

Constipation is a common gastrointestinal disorder that impairs quality of life. Evaluating bowel motility via traditional methods, such as MRI and radiography, is expensive and inconvenient. Bowel sound (BS) analysis has been proposed as an alternative, with BS-time-domain acoustic features (BSTDAFs) being effective for evaluating bowel motility via several food and drink consumption tests. However, the effect of BSTDAFs before drink consumption on those after drink consumption is yet to be investigated. This study used BS-based stimulus-response plots (BSSRPs) to investigate this effect on 20 participants who underwent drinking tests. A strong negative correlation was observed between the number of BSs per minute before carbonated water consumption and the ratio of that before and after carbonated water consumption. However, a similar trend was not observed when the participants drank cold water. These findings suggest that when carbonated water is drunk, bowel motility before ingestion affects motor response to ingestion. This study provides a non-invasive BS-based approach for evaluating motor response to food and drink, offering a new research window for investigators in this field.


Assuntos
Ingestão de Líquidos , Motilidade Gastrointestinal , Humanos , Ingestão de Líquidos/fisiologia , Masculino , Motilidade Gastrointestinal/fisiologia , Feminino , Adulto , Adulto Jovem , Constipação Intestinal/fisiopatologia , Voluntários Saudáveis , Água Carbonatada
17.
Sensors (Basel) ; 24(7)2024 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-38610278

RESUMO

Transient terahertz time-domain spectroscopy (THz-TDS) imaging has emerged as a novel non-ionizing and noninvasive biomedical imaging modality, designed for the detection and characterization of a variety of tissue malignancies due to their high signal-to-noise ratio and submillimeter resolution. We report our design of a pair of aspheric focusing lenses using a commercially available lens-design software that resulted in about 200 × 200-µm2 focal spot size corresponding to the 1-THz frequency. The lenses are made of high-density polyethylene (HDPE) obtained using a lathe fabrication and are integrated into a THz-TDS system that includes low-temperature GaAs photoconductive antennae as both a THz emitter and detector. The system is used to generate high-resolution, two-dimensional (2D) images of formalin-fixed, paraffin-embedded murine pancreas tissue blocks. The performance of these focusing lenses is compared to the older system based on a pair of short-focal-length, hemispherical polytetrafluoroethylene (TeflonTM) lenses and is characterized using THz-domain measurements, resulting in 2D maps of the tissue refractive index and absorption coefficient as imaging markers. For a quantitative evaluation of the lens effect on the image resolution, we formulated a lateral resolution parameter, R2080, defined as the distance required for a 20-80% transition of the imaging marker from the bare paraffin region to the tissue region in the same image frame. The R2080 parameter clearly demonstrates the advantage of the HDPE lenses over TeflonTM lenses. The lens-design approach presented here can be successfully implemented in other THz-TDS setups with known THz emitter and detector specifications.


Assuntos
Lentes , Imagem Terahertz , Animais , Camundongos , Polietileno , Politetrafluoretileno , Temperatura Baixa
18.
Sensors (Basel) ; 24(7)2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38610529

RESUMO

Intelligent vehicle trajectory tracking exhibits problems such as low adaptability, low tracking accuracy, and poor robustness in complex driving environments with uncertain road conditions. Therefore, an improved method of adaptive model predictive control (AMPC) for trajectory tracking was designed in this study to increase the corresponding tracking accuracy and driving stability of intelligent vehicles under uncertain and complex working conditions. First, based on the unscented Kalman filter, longitudinal speed, yaw speed, and lateral acceleration were considered as the observed variables of the measurement equation to estimate the lateral force of the front and rear tires accurately in real time. Subsequently, an adaptive correction estimation strategy for tire cornering stiffness was designed, an AMPC method was established, and a dynamic prediction time-domain adaptive model was constructed for optimization according to vehicle speed and road adhesion conditions. The improved AMPC method for trajectory tracking was then realized. Finally, the control effectiveness and trajectory tracking accuracy of the proposed AMPC technique were verified via co-simulation using CarSim and MATLAB/Simulink. From the results, a low lateral position error and heading angle error in trajectory tracking were obtained under different vehicle driving conditions and road adhesion conditions, producing high trajectory-tracking control accuracy. Thus, this work provides an important reference for improving the adaptability, robustness, and optimization of intelligent vehicle tracking control systems.

19.
Nano Lett ; 23(24): 11685-11692, 2023 Dec 27.
Artigo em Inglês | MEDLINE | ID: mdl-38060838

RESUMO

The rapid development of 6G communications using terahertz (THz) electromagnetic waves has created a demand for highly sensitive THz nanoresonators capable of detecting these waves. Among the potential candidates, THz nanogap loop arrays show promising characteristics but require significant computational resources for accurate simulation. This requirement arises because their unit cells are 10 times smaller than millimeter wavelengths, with nanogap regions that are 1 000 000 times smaller. To address this challenge, we propose a rapid inverse design method using physics-informed machine learning, employing double deep Q-learning with an analytical model of the THz nanogap loop array. In ∼39 h on a middle-level personal computer, our approach identifies the optimal structure through 200 000 iterations, achieving an experimental electric field enhancement of 32 000 at 0.2 THz, 300% stronger than prior results. Our analytical model-based approach significantly reduces the amount of computational resources required, offering a practical alternative to numerical simulation-based inverse design for THz nanodevices.

20.
Nano Lett ; 23(9): 3835-3841, 2023 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-37126575

RESUMO

Free-space time domain THz spectroscopy accesses electrodynamic responses in a frequency regime ideally matched to interacting condensed matter systems. However, THz spectroscopy is challenging when samples are physically smaller than the diffraction limit of ∼0.5 mm, as is typical, for example, in van der Waals materials and heterostructures. Here, we present an on-chip, time-domain THz spectrometer based on semiconducting photoconductive switches with a bandwidth of 200 to 750 GHz. We measure the optical conductivity of a 7.5-µm wide NbN film across the superconducting transition, demonstrating spectroscopic signatures of the superconducting gap in a sample smaller than 2% of the Rayleigh diffraction limit. Our spectrometer features an interchangeable sample architecture, making it ideal for probing superconductivity, magnetism, and charge order in strongly correlated van der Waals materials.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA