Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 168
Filtrar
1.
Biofouling ; 40(2): 114-129, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38538551

RESUMO

This study aimed to answer the question formulated according to the PICO strategy: 'Which essential oils show antimicrobial activity against biofilms formed on dental acrylic resin?' composed by population (dental acrylic resin), intervention (application of essential oils), comparison (denture cleansers, antifungal drugs, chlorhexidine, and oral mouthwashes), and outcome (antibiofilm activity). In vitro experimental studies evaluating the activity of EOs on biofilm formed on acrylic resin were included. PRISMA guidelines were followed, and the search was performed in the PubMed, Science Direct, Embase, and Lilacs databases and in the gray literature using Google Scholar and ProQuest in December 2023. A manual search of the reference lists of the included primary studies was performed. Of the 1467 articles identified, 37 were selected for full-text reading and 12 were included. Twelve EOs were evaluated, of which 11 showed activity against Candida spp., 3 against Staphylococcus aureus, and 1 against Pseudomonas aeruginosa. The EOs of Cymbopogon citratus, Cinnamomum zeylanicum, and Cymbopogon nardus showed higher action than chlorhexidine, C. nardus higher than Listerine, C. citratus higher than nystatin, and Melaleuca alternifolia higher than fluconazole and nystatin. However, chlorhexidine was more effective than Lippia sidoides and Salvia officinalis, sodium hypochlorite was more effective than L. sidoides, nystatin was more effective than Zingiber officinale, Amphotericin B more effective than Eucalyptus globulus and M. alternifolia. In conclusion, the EOs of C. zeylanicum, C. citratus, C. nardus, and M. alternifolia showed antimicrobial activity to reduce biofilm on dental acrylic resin.


Assuntos
Resinas Acrílicas , Biofilmes , Óleos Voláteis , Antifúngicos/farmacologia , Biofilmes/efeitos dos fármacos , Candida albicans , Clorexidina/farmacologia , Nistatina/farmacologia , Óleos Voláteis/farmacologia
2.
Dent Mater ; 40(2): 348-358, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38142145

RESUMO

OBJECTIVE: The objective was to synthesize halloysite nanotubes loaded with chlorhexidine (HNT/CHX) and evaluate the antimicrobial activity, microhardness, color change, and surface characteristics of an experimental self-curing acrylic resin containing varying concentrations of the synthesized nanomaterial. METHODS: The characterization of HNT/CHX was carried out by calculating incorporation efficiency, morphological and compositional, chemical and thermal evaluations. SAR disks were made containing 0 %, 3 %, 5 %, and 10 % of HNT/CHX. Specimens (n = 3) were immersed in distilled water and spectral measurements were carried out using UV/Vis spectroscopy to evaluate the release of CHX for up to 50 days. The antimicrobial activity of the composite against Candida albicans and Streptococcus mutans was evaluated by disk-diffusion test. Microhardness, color analyses (ΔE), and surface roughness (Ra) (n = 9) were performed before and after 30 days of immersion. Data were analyzed using ANOVA/Bonferroni. {Results.} The incorporation efficiency of CHX into HNT was of 8.15 %. All test groups showed controlled and cumulative CHX release up to 30 or 50 days. Significant antimicrobial activity was verified against both microorganisms (p < 0.001). After the 30-day immersion period, the 10 % HNT/CHX group showed a significant increase in hardness (p < 0.05) and a progressive color change (p < 0.001). At T0, the 5 % and 10 % groups exhibited Ra values similar to the control group (p > 0.05), while at T30, all groups showed similar roughness values (p > 0.05). {Significance.} The modification of a SAR with HNT/CHX provides antimicrobial effect and controlled release of CHX, however, the immediate surface roughness in the 3 % group was compromised when compared to the control group.


Assuntos
Anti-Infecciosos , Nanotubos , Clorexidina/farmacologia , Clorexidina/química , Resinas Acrílicas/química , Argila , Teste de Materiais , Propriedades de Superfície
3.
Antibiotics (Basel) ; 13(3)2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-38534708

RESUMO

Oral infections occur due to contact between biofilm rich in Candida albicans formed on the inner surface of complete dentures and the mucosa. This study investigated historical advances in the prevention and treatment of oral mucosal infection and identified gaps in the literature. Bibliographic research was conducted, looking at PubMed, Embase, Web of Science, and Scopus, where 935 articles were found. After removing duplicates and excluding articles by reading the title and abstract, 131 articles were selected for full reading and 104 articles were included. Another 38 articles were added from the gray literature. This review followed the PRISMA-ScR guidelines. The historical period described ranges from 1969 to 2023, in which, during the 21st century, in vitro and in vivo studies became more common and, from 2010 to 2023, the number of randomized controlled trials increased. Among the various approaches tested are the incorporation of antimicrobial products into prosthetic materials, the improvement of oral and denture hygiene protocols, the development of synthetic and natural products for the chemical control of microorganisms, and intervention with local or systemic antimicrobial agents. Studies report good results with brushing combined with sodium hypochlorite, and new disinfectant solutions and products incorporated into prosthetic materials are promising.

4.
Saudi Dent J ; 36(5): 765-769, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38766280

RESUMO

Background: The objective of this study was to compare the cytotoxicity of TDV and Rebase II denture hard liners on human gingival fibroblasts, aiming to address issues associated with incomplete polymerization and free monomers that affect material properties. Methods: Seventy-two specimens (24 each of TDV, Rebase II, and controls) were prepared under aseptic conditions according to factory instructions. Cytotoxicity was determined using the MTT test with methyl tetrazolium salt added to the cell culture medium. A two-way ANOVA and a post-hoc Tukey test was used to evaluate the results of incubation before mitochondrial activity was measured using Multiscan spectrophotometry (570 nm). Results: There were significant differences in cell viability between the groups after 24 hours (P < 0.001), with TDV having higher viability than Rebase II. The difference between Rebase II and TDV, however, was not significant at 48 and 96 hours (P > 0.131). At 24 hours, Rebase II exhibited significantly lower viability than TDV liner, with a significant difference between the two groups (P = 0.001). Conclusion: Due to the maximum monomer release in the early hours of incubation, the amount of cytotoxicity decreased with increasing incubation time.

5.
Materials (Basel) ; 16(24)2023 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-38138792

RESUMO

Novel method of obtaining functional acrylic resins (FARs) containing carboxyl- and benzophenone groups (in-chain functionalization) and terminal Br atoms was verified. Acrylic oligomers were prepared by a solution-free, UV-initiated telomerization process of basic monomer (n-butyl acrylate) and functional monomers (acrylic acid and 4-acrylooxybenzophenone) in the presence of radical photoinitiator and different amount of tetrabromomethane (CBr4) as telogen. The effect of telogen content on UV-telomerization kinetics as well as physicochemical and thermal (Tg) properties of FARs was investigated. A telogen content higher than 5 wt. parts does not affect the UV-telomerization rate (photo-DSC), the molecular weights of telomers (GPC), or their glass transition temperature (DSC), but it significantly increases the conversion of monomers (up to 88%) and lowers the viscosity of FARs (approx. 6 Pa·s). NMR studies confirmed the inclusion of CBr4 in the structure of functional acrylic telomers.

6.
J. appl. oral sci ; 32: e20230326, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1558246

RESUMO

Abstract Studies evaluating the roughness, wettability and microbial adhesion of 3D-printed resins for complete denture bases and teeth are scarce. Objective This study evaluated the surface roughness, wettability and adhesion of multispecies biofilms (Candida albicans, Staphylococcus aureus and Streptococcus mutans) on 3D-printed resins for complete denture bases and teeth compared to conventional resins (heat-polymerized acrylic resin; artificial pre-fabricated teeth). Methodology Circular specimens (n=39; 6.0 mm Ø × 2.0 mm) of each group were subjected to roughness (n=30), wettability (n=30) and biofilm adhesion (n=9) tests. Three roughness measurements were taken by laser confocal microscopy and a mean value was calculated. Wettability was evaluated by the contact angle of sessile drop method, considering the mean of the three evaluations per specimen. In parallel, microorganism adhesion to resin surfaces was evaluated using a multispecies biofilm model. Microbial load was evaluated by determining the number of Colony Forming Units (CFU/mL) and by scanning electron microscopy (SEM). Data were subjected to the Wald test in a generalized linear model with multiple comparisons and Bonferroni adjustment, as well as two-way ANOVA (α=5%). Results The roughness of the conventional base resin (0.01±0.04) was lower than that of the conventional tooth (0.14±0.04) (p=0.023) and 3D-printed base (0.18±0.08) (p<0.001). For wettability, conventional resin (84.20±5.57) showed a higher contact angle than the 3D-printed resin (60.58±6.18) (p<0.001). Higher microbial loads of S. mutans (p=0.023) and S. aureus (p=0.010) were observed on the surface of the conventional resin (S. mutans: 5.48±1.55; S. aureus: 7.01±0.57) compared to the 3D-printed resin (S. mutans: 4.11±1.96; S. aureus: 6.42±0.78). The adhesion of C. albicans was not affected by surface characteristics. The conventional base resin showed less roughness than the conventional dental resin and the printed base resin. Conclusion The 3D-printed resins for base and tooth showed less hydrophobicity and less adhesion of S. mutans and S. aureus than conventional resins.

7.
Pesqui. bras. odontopediatria clín. integr ; 23: e210147, 2023. tab, graf
Artigo em Inglês | LILACS, BBO - odontologia (Brasil) | ID: biblio-1431045

RESUMO

Abstract Objective: To determine the effect of ozonated water on the color stability of denture tooth and denture bases. Material and Methods: Thirty denture base discs consisting of 15 Acropars and 15 ProBase Hot specimens with the dimensions of 40 × 5 mm were prepared. Fifteen denture teeth in shade A1 (Ivoclar Vivadent, Schaan, Liechtenstein) were mounted in a specific acrylic jig. All specimens were immersed in three solutions (1% sodium hypochlorite, ozonated water, and distilled water) for four months (one year of clinical use). Color measurements were done with a spectrophotometer and assessed using the CIE L*a*b* colorimetric system (0, 4, 8, 12, and 16 weeks). Data were analyzed using the three-way ANOVA and Tukey test (α=0.05). Results: Tukey's post hoc test revealed a significant change in color in the Acropars denture base for the distilled water group compared to the ozonated water and 1% hypochlorite (p<0.05). Regarding the ProBase Hot denture base, significantly less color change was observed in the 1% hypochlorite group compared to the ozonated water and distilled water (p≤0.001). For the denture teeth, significantly less color change was seen in the distilled water group than in the ozonated water (p=0.015) and 1% hypochlorite (p<0.05) groups. Conclusion: The color change of denture bases and denture tooth in ozonated water are acceptable. Ozonated water can be considered a good disinfectant for cleaning dentures.


Assuntos
Ozônio/uso terapêutico , Cor , Polimento Dentário , Prótese Total , Resinas Acrílicas , Água Destilada , Análise de Variância , Higienizadores de Dentadura/efeitos adversos , Polimerização
8.
Artigo em Zh | WPRIM | ID: wpr-991792

RESUMO

Objective:To investigate the clinical efficacy of carbomer hemorrhoid gel in the treatment of second-degree internal hemorrhoid bleeding.Methods:A total of 160 anorectal outpatients with second-degree internal hemorrhoid bleeding who received treatment in Zhuhai Hospital of Integrated Traditional Chinese and Western Medicine from January 2017 to January 2021 were included in this study. They were randomly divided into an observation group and a control group ( n = 80/group). In the observation group, carbomer hemorrhoid gel was used to plug the anus, while in the control group, a hemorrhoid suppository was used to plug the anus. All patients were treated for 7 days. Clinical efficacy was compared between the two groups. Results:After 4 days of treatment, the bleeding score in the observation group was lower than that in the control group [1(0) point vs. 2(1) points, Z = -6.70, P < 0.05). After 7 days of treatment, the bleeding score in the observation group was significantly lower than that in the control group [0(1) point vs. 1(1) point, Z = -4.73, P < 0.05]. After 4 days of treatment, there was no significant difference in the size score of the hemorrhoids between the two groups ( P > 0.05). After 4 days of treatment, the size score of hemorrhoids in the control group did not differ significantly compared with before treatment ( P > 0.05). After 4 days of treatment, the size score of hemorrhoids in the observation group differed significantly compared with before treatment ( Z = -3.16, P < 0.05). After 7 days of treatment, the size score of the hemorrhoids in the observation group was lower than that in the control group [1(1) point vs. 1(0) point, Z = -4.48, P < 0.05]. The total response rate in the observation group was significantly higher than that in the control group [97.5% (78/80) vs. 75% (60/80), Z = -4.50, P < 0.05]. Conclusion:Carbomer hemorrhoid gel is a new drug used to treat hemorrhoids. It has a new dosage form, has no stimulation to the rectum, and is safe to use. Carbomer hemorrhoid gel is highly effective on second-degree internal hemorrhoid bleeding and deserves clinical popularization.

9.
Rev. odontol. UNESP (Online) ; 52: e20230006, 2023. tab, ilus
Artigo em Inglês | LILACS, BBO - odontologia (Brasil) | ID: biblio-1442091

RESUMO

Introduction: with the technological advance in dentistry, light-polymerized three-dimensional (3D) printing resins had become an alternative for the manufacture of occlusal splint splints. Objective: the present study aimed to analyze the flexural strength of a resin for 3D printing compared to conventional acrylic resins (chemically activated and thermally activated), under the influence of thermocycling. Material and method: 60 specimens were made, which were distributed in six experimental groups (n = 10), according to the resin employed (chemically activated acrylic resin, thermally activated acrylic resin and 3D printing resin) and the treatment received (control and thermocycling). The specimens were submitted to flexural strength by the three-point flexural test. Result: data analysis showed that the material factor (<0.0001) and the thermocycling factor (p = 0.0096) influenced flexural strength, however, the interaction between the two factors did not (p = 0.9728). Conclusion: it was concluded that 3D printing resins presented the lowest flexural resistance to acrylic resins, especially when submitted to thermocycling.


Introdução: com o avanço tecnológico dentro da odontologia, as resinas fotopolimerizáveis para impressão tridimensional (3D) se tornaram uma alternativa para a fabricação de dispositivos interoclusais. Objetivo: o presente trabalho teve como objetivo analisar a resistência flexural de uma resina para impressão tridimensional comparada com resinas acrílicas convencionais (quimicamente ativada e termicamente ativada), sob a influência da termociclagem. Material e método: foram confeccionados 60 corpos de prova, que foram distribuídos aleatoriamente em seis grupos experimentais (n=10), de acordo com a resina utilizada (resina acrílica ativada quimicamente, resina acrílica ativada termicamente e resina para impressão 3D) e com o tratamento recebido (controle e termociclagem). Os corpos de prova foram submetidos ao ensaio de flexão de três pontos para determinação da resistência flexural. Resultado: a análise dos dados demonstrou que o fator material (<0.0001) e o fator termociclagem (p=0.0096) influenciaram a resistência flexural, entretanto, a interação entre os dois fatores não (p=0.9728). Conclusão: deste modo podemos concluir que a resina para impressão 3D apresentou desempenho inferior às resinas acrílicas, especialmente quando submetida a termociclagem.


Assuntos
Resinas Acrílicas , Placas Oclusais , Resinas , Impressão Tridimensional , Resistência à Flexão
10.
Braz. dent. sci ; 26(3): 1-6, 2023. ilus, tab
Artigo em Inglês | LILACS, BBO - odontologia (Brasil) | ID: biblio-1509829

RESUMO

Objective: Teeth play a crucial role in masticatory efficiency and esthetic harmony making rehabilitation of partially edentulous patients a challenge because of the limitations of conventional removable partial dentures. As a therapeutic alternative, thermoplastic polymers are used in current dental practice either for practical processing purposes or aesthetics. However, it is recognized that the bond between acrylic resin artificial teeth and thermoplastic polymers has no chemical interaction, and depends on retentive features added to the teeth. This study analyzed the efficacy of two retentive forms of features through compressive strength test and as a secondary outcome, fracture and displacement resistance test. Material and Methods: Three groups of samples each with 14 sets of acrylic teeth were compared when two retentive features, single hole and groove retention, and a control group with teeth without any specific form. The experimental unit consisted of six maxillary anterior teeth, positioned in a linear pattern into a polypropylene block, where each tooth was submitted to a static load until its removal, on a universal testing machine. Results: Those specimens with a groove retention presented larger resistance to displacement when compared to the other groups (p <0.05). This was emphasized by the fracture of the tooth tested, with part of the cervical portion remaining embed in the base, and not its displacement as with (or without) the retentive feature. Conclusion: In this study, the type of retention influenced significantly to a better retention considering teeth and thermoplastic polymer base. The data in this study indicates that a groove placed on the artificial tooth offers significantly better retention efficacy to the point where the displacement was only possible after its fracture (AU)


Objetivo: Os dentes são um fator essencial na eficiência mastigatória. A harmonia estética e a reabilitação dos indivíduos parcialmente dentados tornam-se um desafio, frente às limitações das próteses parciais removíveis convencionais. Como uma alternativa terapêutica, os polímeros termoplásticos são utilizados na odontologia contemporânea, tanto para o seu processamento prático como seu apelo estético. Entretanto, pouco se sabe a respeito da união entre a resina acrílica de dentes artificiais e resinas termoplásticas, assim como a influência dos mecanismos de retenção, uma vez que não há interação química entre eles. O objetivo deste estudo foi analisar duas formas de retenção de dentes de resina acrílica a bases de prótese de material termoplástico, por força compressiva e como desfecho secundário, teste de resistência a fratura e deslocamento dos dentes artificiais. Material e Métodos: O presente estudo analisou dois tipos diferentes de retenções: uma cavidade com único ponto e uma canaleta de mesial a distal; e como grupo controle, dentes colocados sem qualquer recurso específico. A unidade experimental consistiu de seis dentes superiores anteriores, posicionados em linha em um bloco de polipropileno. Em cada dente artificial foi aplicada força até a sua remoção, em uma máquina universal de ensaios. Resultados: Os resultados mostraram que a retenção com canaleta apresentou maior força de deslocamento, quando comparado com os outros grupos (p <0,05). Tal fato foi evidenciado pelo teste de fratura e deslocamento, no qual parte da porção cervical do dente artificial permaneceu unida à base, não ocorrendo o deslocamento com (ou sem) a retenção. Conclusão: Neste estudo, o tipo de retenção influenciou de forma significante a retenção de dentes artificiais de resina acrílica a bases de prótese termoplásticas. Os dados deste estudo indicam que a confecção da retenção em canaleta nos dentes artificiais oferece significante aumento na eficiência da retenção, ao ponto em que o deslocamento do dente ocorreu somente após sua fratura (AU).


Assuntos
Polipropilenos , Dente Artificial , Resinas Acrílicas , Dentaduras
11.
Braz. oral res. (Online) ; 36: e007, 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - odontologia (Brasil) | ID: biblio-1355939

RESUMO

Abstract Biofilm on acrylic resin dental prostheses may cause gingival inflammation. This study evaluated the influence of a silicon dioxide coating layer applied onto acrylic resin on the adhesion of microorganisms. Blocks (5 x 5 x 3 mm) of acrylic resin were evaluated for surface roughness and divided into two groups: control (CG) and coated with silicon dioxide (LG group). The specimens were evaluated by scanning electron microscopy (n = 1) and by contact angle analysis (n = 3). For the in situ study, 20 volunteers wore acrylic palatal devices containing three samples from each group (n = 60) for 2 days. The biofilm formed was quantified by metabolic activity and total biomass using the crystal violet assay. The results were subjected to Bartlett's normality test and Gamma model with random effect for the response variable (α = 5%). The mean contact angle of the coated group was significantly lower than that of the uncoated group (p < 0.05). The metabolic activity of microorganisms in the biofilm on the blocks treated with coating was significantly lower than that of control blocks (p = 0.02). Regarding the amount of extracellular matrix produced by the microorganisms, there was no difference between the CG and LG group (p = 0.05). The application of a silicon dioxide coating on acrylic resin reduced the activity of the polymicrobial biofilm formed in situ. This coating may be advantageous for patients with conventional complete dentures or implants made of acrylic resin and who have motor difficulties that prevent them from cleaning their prostheses properly.

12.
Braz. dent. sci ; 25(4): 1-7, 2022. tab
Artigo em Inglês | LILACS, BBO - odontologia (Brasil) | ID: biblio-1397461

RESUMO

Objective: The rough surfaces of removable appliances used in pediatric dentistry or orthodontics, may result in an environment for biofilm accumulation, yielding to enamel demineralization. This study aimed to assess the effects of adding nanoparticles of bioactive glass to polymethylmethacrylate to promote the antibacterial activity in acrylic resins. Material and Methods: Acrylic resin specimens (20x20x1mm3) were prepared by adding 2% or 5% bioactive glass. The specimens in the control group without bioactive glass were prepared from the mixture of acrylic powder containing nanoparticles and liquid monomer (n=10 per group). The antibacterial activity of the specimens against Streptococcus mutans and Lactobacillus acidophilus activity in biofilm was investigated through counting colony forming units (CFU). Data were analyzed using a one-way analysis of variance and Tukey's post hoc tests at the significance level of 0.05. Results: The incorporation of 2% (p=0.001) and 5% (p<0.001) bioactive glass in acrylic resin reduced the metabolic activity and CFU of L. acidophilus. For S.mutans, antimicrobial activity was observed only with the 5% concentration of bioactive glass, and this group was statistically different from the control (p<0.001). When L. acidophilus was exposed to polymethyl methacrylate with 5% bioactive glass, significant decrease was observed compared to the control group (p<0.05). Conclusion: Adding bioactive glass nanoparticles into the acrylic resins used for fabricating removable appliances revealed a greater antibacterial effect against cariogenic bacteria tested (AU)


Objetivo: As superfícies rugosas dos aparelhos removíveis utilizados em Odontopediatria ou Ortodontia, podem resultar em um ambiente para acúmulo de biofilme, cedendo à desmineralização do esmalte. Este estudo teve como objetivo avaliar os efeitos da adição de nanopartículas de vidro bioativo ao polimetilmetacrilato para promover a atividade antibacteriana em resinas acrílicas. Material e Métodos: Amostras de resina acrílica (20x20x1 mm3) foram preparadas pela adição de 2% ou 5% de vidro bioativo. Os corpos de prova do grupo controle sem vidro bioativo foram preparados a partir da mistura de pó acrílico contendo nanopartículas e monômero líquido (n=10 por grupo). A atividade antibacteriana dos espécimes sobre a atividade de Streptococcus mutans e Lactobacillus acidophilus em biofilme foi investigada através da contagem de unidades formadoras de colônias (UFC). Os dados foram analisados por meio de análise de variância unidirecional e testes post hoc de Tukey com nível de significância de 0,05. Resultados: A incorporação de 2% (p=0,001) e 5% (p<0,001) de vidro bioativo em resina acrílica reduziu a atividade metabólica e UFC de L. acidophilus. Para S. mutans, a atividade antimicrobiana foi observada apenas com a concentração de 5% de vidro bioativo, sendo este grupo estatisticamente diferente do controle (p<0,001). Quando L. acidophilus foi exposto ao polimetilmetacrilato com 5% de vidro bioativo, foi observada diminuição significativa em relação ao grupo controle (p<0,05). Conclusão: A adição de nanopartículas de vidro bioativo nas resinas acrílicas utilizadas na fabricação de aparelhos removíveis revelou um maior efeito antibacteriano contra as bactérias cariogênicas testadas(AU)


Assuntos
Resinas Acrílicas , Materiais Dentários , Odontólogos , Antibacterianos
13.
J. oral res. (Impresa) ; 11(6): 1-10, nov. 3, 2022. ilus, tab
Artigo em Inglês | LILACS | ID: biblio-1437657

RESUMO

Aim: To assess the effect of different mechanical surface treatments on flexural strength of repaired denture base. Material and Methods: Sixty bar-shaped specimens of heat-polymerized acrylic resin were fabricated, and divided into six groups (n=10). All specimens, except the positive control group (group PC), were sectioned into halves to create a 1-mm clearance. A negative control group with no surface treatment (group NC) was also considered. Other groups underwent different surface treatments: group Laser; treated with erbium: yttrium-aluminum-garnet (Er:YAG) laser, group APA; airborne-particle abrasion (APA), group APA plus Laser; a combination of laser and APA, and group Bur; bur grinding. After measuring surface roughness (Ra) with a profilometer, all sectioned specimens were repaired by auto-polymerizing acrylic resin, and thermocycled afterward. Three-point bending test was performed by a universal testing machine. Data were statistically analyzed (α=0.05). Results: The mean surface roughness of all experimental groups were significantly higher than that of group NC (p<0.05). The mean flexural strength of all groups was significantly lower than that of group PC (p<0.05). Group B had significantly higher flexural strength than the other surface-treated groups (p<0.05). Group Laser had significantly higher flexural strength than groups APA (p=0.043) and APA plus Laser (p=0.023). No significant difference was found between groups APA and APA plus Laser (p=0.684). Conclusion: All surface treatments increased the surface roughness and flexural strength compared with the untreated group. The highest flexural strength was observed in specimens treated by bur grinding and then laser, however, it was still significantly lower than intact specimens.


Objetivo: Evaluar el efecto de diferentes tratamientos superficiales mecánicos sobre la resistencia a la flexión de la base de la prótesis reparada. Material y Métodos: Se fabricaron sesenta especímenes en forma de barra de resina acrílica termo-polimerizada y se dividieron en seis grupos (n=10). Todas las muestras, excepto el grupo de control positivo (grupo PC), se seccionaron en mitades para crear un espacio libre de 1 mm. También se consideró un grupo de control negativo sin tratamiento superficial (grupo NC). Otros grupos se sometieron a diferentes tratamientos superficiales: grupo Láser; tratados con láser de erbio: itrio-aluminio-granate (Er:YAG), grupo APA; abrasión por partículas en el aire (APA), grupo APA más láser; una combinación de láser y APA, y grupo Bur; molienda de fresas. Después de medir la rugosidad de la superficie (Ra) con un perfilómetro, todas las muestras seccionadas se repararon con resina acrílica de autopolimerización y se sometieron a termociclado. La prueba de flexión de tres puntos se realizó con una máquina de prueba universal. Los datos se analizaron estadísticamente (α=0,05). Resultados: La rugosidad superficial media de todos los grupos experimentales fue significativamente mayor que la del grupo NC (p<0,05). La resistencia media a la flexión de todos los grupos fue significativamente menor que la del grupo PC (p<0,05). El grupo B tenía una resistencia a la flexión significativamente mayor que los otros grupos tratados en la superficie (p<0,05). El grupo Láser tuvo una resistencia a la flexión significativamente mayor que los grupos APA (p=0,043) y APA más Láser (p=0,023). No se encontró diferencia significativa entre los grupos APA y APA más Láser (p=0,684). Conclusión: Todos los tratamientos superficiales aumentan la rugosidad de la superficie y la resistencia a la flexión en comparación con el grupo sin tratar. La resistencia a la flexión más alta se observó en las muestras tratadas con fresado y luego con láser; sin embargo, aún era significativamente más baja que las muestras intactas.


Assuntos
Humanos , Resinas Acrílicas/química , Reparação em Dentadura , Polimetil Metacrilato/química , Materiais Dentários/química , Bases de Dentadura , Lasers de Estado Sólido , Metacrilatos/química
14.
J. appl. oral sci ; 29: e20210024, 2021. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1340097

RESUMO

Abstract Understanding the behavior of Candida spp. when exposed to denture disinfectants is essential to optimize their effectiveness. Changes in the virulence factors may cause increased resistance of Candida spp. to disinfectant agents. Objective To evaluate the microbial load, cellular metabolism, hydrolytic enzyme production, hyphae formation, live cell and biofilm quantification of Candida albicans, Candida tropicalis and Candida glabrata after exposure to disinfectant solutions. Methodology Simple biofilms were grown on heat-polymerized acrylic resin specimens, and divided into groups according to solutions/strains: distilled water (control); 0.25% sodium hypochlorite (NaOCl 0.25% ); 10% Ricinus communis (RC 10%); and 0.5% Chloramine T (CT 0.5%). The virulence factors were evaluated using the CFU count (microbial load), XTT method (cell metabolism), epifluorescence microscopy (biofilm removal and live or dead cells adhered), protease and phospholipase production and hyphae formation. Data were analyzed (α=0.05) by one-way ANOVA/ Tukey post hoc test, Kruskal-Wallis test and Wilcoxon test. Results NaOCl 0.25% was the most effective solution. CT 0.5% reduced the number of CFUs more than RC 10% and the control. RC 10% was effective only against C. glabrata. RC 10% and CT 0.5% decreased the cellular metabolism of C. albicans and C. glabrata. Enzyme production was not affected. Hyphal growth in the RC 10% and CT 0.5% groups was similar to that of the control. CT 0.5% was better than RC 10% against C. albicans and C. tropicalis when measuring the total amount of biofilm and number of living cells. For C. glabrata, CT 0.5% was equal to RC 10% in the maintenance of living cells; RC 10% was superior for biofilm removal. Conclusions The CT 0.5% achieved better results than those of Ricinus communis at 10%, favoring the creation of specific products for dentures. Adjustments in the formulations of RC 10% are necessary due to efficacy against C. glabrata. The NaOCl 0.25% is the most effective and could be suitable for use as a positive control.


Assuntos
Candida , Desinfetantes , Resinas Acrílicas , Candida albicans , Biofilmes , Fatores de Virulência
15.
Odovtos (En línea) ; 23(2)ago. 2021.
Artigo em Inglês | LILACS, SaludCR | ID: biblio-1386539

RESUMO

ABSTRACT: The purpose of this study was to evaluate and compare the effect of carbonated beverage on the surface microhardness of two acrylic materials used to fabricate temporary restorations. The study was experimental in vitro. Forty blocks of acrylic resins used in provisional restorations were made, 20 from Alike® (GC AMERICA INC., Lot 1712161) and 20 from Acryptemp® (Zhermack S.P.A., Lot 302334). After that, the blocks were immersed in distilled water for 24 hours. After this time, the initial surface microhardness was measured. Then the 20 samples of the experimental group were immersed in a carbonated drink (coca cola - soda) for 12 minutes per day, for 5 days. Finally, the final surface microhardness was measured using the Vickers microdurometer. Measures of central tendency and dispersion were used, and the Student's t test and ANOVA were performed. A mean surface microhardness of 8.8 and 7.2HV was found for the PMMA resin group (Initial and final respectively), and 9.5 and 8HV for the bisacrylate group. Statistically significant differences were found when comparing the beginning and end of each group and when comparing the two materials. The acrylic resin of polymethylmethacrylate (Alike® GC AMERICA INC.) Presented higher surface microhardness compared to the bis acrylic resin (Acrytemp® Zhermack S.P.A), after being exposed to a carbonated drink.


RESUMEN: El propósito de este estudio fue evaluar y comparar el efecto de la bebida carbonatada en la microdureza superficial de dos materiales acrílicos utilizados para confeccionar restauraciones provisionales. El estudio fue experimental in vitro. Se confeccionaron 40 bloques de resinas acrílicas utilizadas en provisorios, 20 de Alike® (GC AMERICA INC., Lote 1712161) y 20 de Acryptemp® (Zhermack S.P.A., Lote 302334). Posterior a ello, se sumergió los bloques en agua destilada por 24 horas. Pasado este tiempo se procedió a medir la microdureza superficial inicial. Luego las 20 muestras del grupo experimental se sumergieron en una bebida carbonatada (coca cola-gaseosa) durante 12 minutos por día, durante 5 días. Por último se midió la microdureza superficial final mediante el microdurómetro de Vickers. Se utilizaron medidas de tendencia central, dispersión y se realizaron la prueba t de Student y ANOVA. Se encontró una microdureza superficial media de 8,8 y 7,2HV para el grupo de resina PMMA (Inicial y final respectivamente), y 9,5 y 8HV para el grupo de bisacrilato. Se halló diferencias estadísticamente significativas al comparar el inicio y final de cada grupo y al comparar los dos materiales. La resina acrílica de polimetilmetacrilato (Alike® GC AMERICA INC.) presentó mayor microdureza superficial en comparación con la resina bis acrílica (Acrytemp® Zhermack S.P.A), después de ser expuestas a una bebida carbonatada.


Assuntos
Resinas Acrílicas/análise , Bebidas Gaseificadas/efeitos adversos , Peru , Dureza
16.
Rev. Ciênc. Méd. Biol. (Impr.) ; 20(3): 485-490, dez 20, 2021. fig
Artigo em Português | LILACS | ID: biblio-1354357

RESUMO

Introdução: os dentes artificiais de resina acrílica são amplamente utilizados na confecção de próteses, por apresentarem propriedades físicas, mecânicas e biológicas, além de características de fácil manuseio. No entanto, devido sua característica de baixa resistência à abrasão, a escovação pode levar à perda de massa dos dentes artificiais e aumento da rugosidade. Objetivo: avaliar de forma qualitativa a rugosidade superficial e polimento de dentes artificiais das marcas Hereaus Premium; Trilux e Vita, após período de 1 ano de escovação, com fotografias em Lupa Estereoscópica. Metodologia: para a realização deste estudo, serão utilizados 10 dentes artificiais de cada marca comercial (Trilux, Vita e Hereaus Premium). Os dentes serão fixados com resina ortoftálica em tubo de PVC de 15 mm de espessura. Para o teste de abrasão, será usada uma máquina de escovação simulada com escovas de dentes de cerdas macias e solução de pasta de dente. As imagens serão obtidas com câmera digital acoplada a lupa estereoscópica. A rugosidade superficial e o polimento serão analisados antes da escovação simulada e após 12 meses de escovação através das imagens. Resultados: após o teste de abrasão foi observado a presença de um desgaste superficial e/ou ranhuras na superfície dos dentes artificiais em todos os grupos. Porém não houve um padrão similar entre os corpos de prova de um mesmo grupo. Conclusão: Pode-se concluir que a escovação provocou o aumento da rugosidade superficial e alteração no polimento em todos os dentes artificiais utilizados.


Introduction: acrylic resin artificial teeth are widely used in the manufacture of dentures, as they have physical, mechanical and biological properties, in addition to easy handling characteristics. However, due to its characteristic of low abrasion resistance, brushing can lead to loss of mass of artificial teeth and increase in roughness. Objective: qualitatively evaluate the surface roughness and polishing of artificial teeth of Hereaus Premium brands; Trilux and Vita, after a 1-year brushing period, with photographs using a Stereoscopic Magnifying Glass. Methodology: for this study, 10 artificial teeth of each commercial brand will be used (Trilux, Vita and Hereaus Premium). Teeth will be fixed with orthophthalic resin in a 15 mm thick PVC tube. For the abrasion test, a simulated brushing machine with soft bristle toothbrushes and toothpaste solution will be used. Images will be obtained with a digital camera coupled to a stereoscopic magnifying glass. Surface roughness and polishing will be analyzed before simulated brushing and after 12 months of brushing through the images. Results: after the abrasion test, the presence of surface wear and/ or grooves on the surface of the artificial teeth was observed in all groups. However, there was no similar pattern between the specimens of the same group. Conclusion: it can be concluded that brushing caused an increase in surface roughness and change in polishing in all artificial teeth used.


Assuntos
Humanos , Abrasão Dentária , Dente Artificial , Resinas Acrílicas , Escovação Dentária , Revisão
17.
J. health sci. (Londrina) ; 23(1): https://revista.pgsskroton.com/index.php/JHealthSci/article/view/7618, 20210330.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1179417

RESUMO

The acrylic resin used for the prosthesis base accumulates biofilm, causing diseases such as stomatitis. The addition of some nanoparticles promotes antimicrobial action. This study incorporated the nanostructured silver vanadate decorated with silver nanoparticles (AgVO3) to the acrylic resin by two methods and evaluated the cytotoxicity for human gingival fibroblasts (HGF) and the released silver and vanadium ions. The concentrations of 0.5, 1, 2.5, and 5% of AgVO3 was incorporated by vacuum spatulation and polymeric film. The vacuum spatulation was performed for 60 s using the Turbomix equipment, and the polymeric film was obtained from the polymer solubilization in chloroform, the film was subjected to a cryogenic grinding, and the powder obtained was manually mixed at the monomer. HGF cell viability was assessed after 24 hours, 7 and 14 days by the MTT assay. The release of silver (Ag) and vanadium (V) ions were quantified by inductively coupled plasma mass spectrometry after 30 days. Kruskal-Wallis and Dunn's test were applied (α = 0.05). The HGF viability was inversely proportional to the incubation time. Both incorporation techniques and the negative and positive control groups presented significant statistical differences (p<0.05). The experimental groups presented no statistical difference compared to the negative control (p>0.05), except the vacuum spatulation group with 5% of AgVO3 that showed greater viability than the negative control (p=0.013) in 24 hours. The release of Ag and V ions was proportional to the concentration of AgVO3 The 5% group presented a significant difference compared to the other groups (p<0.05). In conclusion, the acrylic resin with and without the AgVO3 incorporation had a small cytotoxic potential for HGF in 24 hours, with a lower viability in longer contact times; the release of Ag and V ions was proportional to the concentration of AgVO3, not influencing cell viability. (AU)


A resina acrílica utilizada para a base da prótese acumula biofilme, causando doenças como a estomatite. A adição de algumas nanopartículas promove ação antimicrobiana. Este estudo incorporou o vanadato de prata nanoestruturado decorado com nanopartículas de prata (AgVO3) à resina acrílica por dois métodos e avaliou a citotoxicidade para fibroblastos gengivais humanos (HGF) e os íons prata e vanádio liberados. As concentrações de 0,5%, 1%, 2,5% e 5% de AgVO3 foram incorporadas por espatulação a vácuo e filme polimérico. A espatulação a vácuo foi realizada por 60 s no equipamento Turbomix, e o filme polimérico foi obtido a partir da solubilização do polímero em clorofórmio, o filme foi submetido a uma moagem criogênica e o pó obtido foi misturado manualmente ao monômero. A viabilidade celular de HGF foi avaliada após 24 horas, 7 e 14 dias pelo ensaio de MTT. A liberação de íons prata (Ag) e vanádio (V) foi quantificada por espectrometria de massa com plasma indutivamente acoplado após 30 dias. Os testes de Kruskal-Wallis e Dunn foram aplicados (α=0,05). A viabilidade de HGF foi inversamente proporcional ao tempo de incubação. As técnicas de incorporação e os grupos controle negativo e positivo apresentaram diferença estatisticamente significante (p<0,05). Os grupos experimentais não apresentaram diferença estatística em relação ao controle negativo (p>0,05), exceto o grupo de espatulação a vácuo com 5% de AgVO3 que apresentou maior viabilidade que o controle negativo (p = 0,013) em 24 horas. A liberação de íons Ag e V foi proporcional à concentração de AgVO3. O grupo 5% apresentou diferença significativa em relação aos demais grupos (p <0,05). Em conclusão, a resina acrílica com e sem a incorporação de AgVO3 apresentou um pequeno potencial citotóxico para o HGF em 24 horas, com menor viabilidade nos tempos de maior contato, e a liberação de íons Ag e V foi proporcional à concentração de AgVO3, não influenciando na viabilidade celular. (AU)

18.
Rev. Fac. Odontol. Univ. Antioq ; 33(1): 6-16, Jan.-June 2021. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1340739

RESUMO

ABSTRACT Introduction: the emerging manufacture technologies for dental restorations have brought new materials with them, such as 3D-printing resins and CAD/CAM discs for the manufacturing of denture bases. Currently, there is no rigorous mechanical characterization for these materials in the literature, apart from the ones reported in technical datasheets. Method: samples for mechanical characterization were manufactured with a conventional heat cure acrylic, a CAD/CAM polymethyl methacrylate (PMMA) disc and two 3D-printing resins. The samples were tested in a universal testing machine, according to ISO 20795-1 for flexural strength and elastic modulus. Compression strength was also determined under dry conditions. The average value of each property was calculated (n = 5). One-way ANOVA and Tukey's multiple comparisons tests were used. Results: mean flexural strengths ranged from 78.35±2.99 to 87.48±4.47MPa, elastic moduli were between 2125.43±57.05 and 2277.72±58.46MPa, and compression strengths values ranged from 85.03±2.14 to 119.15±2.87MPa. Statistical analyses showed significant differences for flexural and compression strengths but did not show any difference for elastic moduli. Conclusions: all the tested materials met the minimum required specification for mechanical properties given by ISO 20795-1. From a mechanical point of view, the new materials for digital technologies, i.e., CAD/CAM disc and 3D-printing resins, are suitable for denture-base applications.


RESUMEN Introducción: con la aparición de nuevas tecnologías de manufactura han surgido nuevos materiales, como resinas de impresión 3D y discos CAD/CAM, todos empleados para fabricación de bases de dentadura. Actualmente no se cuenta con caracterizaciones mecánicas rigurosas para estos materiales, salvo lo expresado en fichas técnicas. Método: se fabricaron muestras para caracterización de propiedades mecánicas con un acrílico termopolimerizable convencional, un disco CAD/CAM de polimetilmetacrilato (PMMA) y dos resinas de impresión 3D. Se fallaron las probetas en una máquina universal de ensayos, según lo exigido por la norma ISO 20795-1 para el caso de la resistencia y módulo de flexión. La resistencia a la compresión también fue determinada. Se calculó el valor promedio de cada propiedad (n = 5). Se realizó un análisis de varianza de una vía y un análisis de Tukey para comparaciones múltiples. Resultados: los valores de resistencia a la flexión oscilaron entre 78.35±2.99 y 87.48±4.47MPa; el módulo de flexión estuvo en un rango entre 2125.43±57.05 y 2277.72±58.46MPa. La resistencia a la compresión fluctuó entre 85.03±2.14 y 119.15±2.87MPa. Los análisis estadísticos indicaron diferencias significativas para las resistencias a la flexión y compresión, pero no evidenciaron diferencias para el módulo de flexión. Conclusiones: todos los materiales evaluados cumplieron con la especificación mínima de propiedades mecánicas, dada por la ISO 20795-1. Desde el punto de vista mecánico, los nuevos materiales para las tecnologías digitales, discos CAD/CAM y resinas de impresión 3D, son aptos para su aplicación en manufactura de bases de dentadura.


Assuntos
Humanos , Prótese Dentária
19.
CES odontol ; 34(1): 44-51, ene.-jun. 2021. tab, graf
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1360260

RESUMO

Resumen Introducción y objetivo: las resinas acrílicas son los materiales idóneos para la elaboración prótesis totales, sin embargo, las caídas o golpes los hace susceptibles de fracturas. Conocer las propiedades y limitaciones de los acrílicos en nuestro entorno, nos permite realizar tratamientos con los mejores materiales. El objetivo de este estudio fue comparar la resistencia al impacto de dos acrílicos convencionales y dos de alto impacto para bases protésicas. Materiales y métodos: se realizaron 40 barras en cera para base para ser enmufladas de acuerdo con especificaciones de cuatro marcas de acrílicos (n=10), Lucitone199®, Masterdent acrylic resin, Veracril alto impacto® y convencional. La resistencia impacto se evaluó mediante la prueba de Charpy (Máquina ITC-XJU-22), con masa de péndulo de 0.237 Kg y fuerza de impacto de 1J. se realizó análisis estadístico por ANOVA a una vía y prueba de tukey. Resultados: los valores de resistencia al impacto fueron 16.5, 10.8, 9.3 y 5.9 KJ/m2 para Lucitone199®, Veracril alto impacto®, Veracril convencional® y Masterdent acrylic resin. Conclusiones: con las limitaciones de esta investigación, los acrílicos de alto impacto se pueden considerar como una alternativa más viable para la elaboración de prótesis totales ante los acrílicos convencionales, en busca de disminuir el riesgo de fracturas por accidentes o cargas repentinas de impacto.


Abstract Introduction and objective: acrylic resins are the ideal materials for the elaboration of dentures and removable prostheses, although the falls or blows make them susceptible to fractures. Knowing the properties and limitations of acrylics in our environment, allows us to carry out treatments with the best materials. The objective of this study was to compare the impact resistance of two conventional and two high impact acrylics for prosthetic bases. Materials and methods: 40 bars were made in base-wax and processed in muffles according to specifications of four trademarks of acrylics (n=10), Lucitone199®, Masterdent acrylic resin®, Veracril alto impacto® and convencional®. The impact resistance was evaluated by the Charpy test (Machine ITC-XJU-22), with a pendulum mass of 0.237 Kg and an impact force of 1J. One-way ANOVA and tukey test were performed for statistical analysis was performed. Results: the impact resistance values were 16.5, 10.8, 9.3 and 5.9 KJ / m2 for Lucitone199®, Veracril alto impacto®, Veracril convencional® and Masterdent acrylic resin®. Conclusions: with the limitations of this investigation, high impact acrylics can be considered as a more viable alternative for the elaboration of dentures compared to conventional acrylics, in order to reduce the risk of fractures due to accidents or sudden impact loads.


Resumo Introdução y objetivo: as resinas acrílicas são os materiais ideais para a elaboração de próteses totais, porém as quedas ou golpes os tornam suscetíveis a fraturas. Conhecer as propriedades e limitações dos acrílicos em nosso ambiente, permite realizar tratamentos com os melhores materiais.. O objetivo deste estudo foi comparar a resistência ao impacto de d ois acrílicos convencionais e dois de alto impacto para bases protéticas. Materiais e métodos: foram feitas 40 barras de cera para que a base seja silenciada de acordo com as especificações de quatro marcas de acrílicos (n=10), Lucitone199®, resina acrílica Masterdent, Veracril high impact® e convencional. A resistência ao impacto foi avaliada pelo teste de Charpy (Máquina ITC-XJU-22), com uma massa pendular de 0.237 kg e uma força de impacto de 1J. Foi realizada análise estatística ANOVA unidirecional e teste de tukey. Resultados: os valores de resistência ao impacto foram de 16.5, 10.8, 9.3 e 5.9 KJ/m2 para a resina acrílica Lucitone199®, Veracril high impact®, Veracril convencional® e Masterdent. Conclusões: com as limitações desta investigação, os acrílicos de alto impacto podem ser considerados uma alternativa mais viável para a elaboração de próteses totais em comparação aos acrílicos convencionais, a fim de reduzir o risco de fraturas devido a acidentes ou cargas de impacto repentinas.

20.
Braz. oral res. (Online) ; 34: e110, 2020. graf
Artigo em Inglês | LILACS, BBO - odontologia (Brasil) | ID: biblio-1132720

RESUMO

Abstract Acrylic resin has been used in the manufacture of prostheses, however, in the oral cavity, this material starts to retain microorganisms capable of causing gingival inflammation due its porosities. The aim of this study was to evaluate the influence of the use of silicon dioxide as a coating layer applied onto acrylic resin, on the adhesion of Candida albicans (Ca). After the incubation period in Sabouraud Dextrose Broth, a total of 1 ml of the Ca suspension was added to plate wells, each well containing a specimen of acrylic resin. The adhesion ability of Ca on acrylic resin was determined by counting colonies. Three groups (n = 6) of acrylic resin were assessed: with polishing (RP); without polishing (RW); with polishing and coating layer of silicon dioxide (RPC). Ca deposited on the surface of the acrylic resin was also observed using Scanning Electron Microscopy (SEM). Statistical assessment by Kruskal-Wallis and Student-Newman-Keuls Method were done (α = 2%). There was significant difference among the groups. The RPC group showed the lowest growth, with an average of 5.59 Log CFU/cm 2 ; there was a statistically significant difference in relation to group RW, which presented a growth of 6.07 Log CFU/cm 2 and to group RP with 5.91 Log CFU/cm 2 (p < 000.1). SEM images demonstrated that in the RP and RPC group, the surface of the resin had greater regularity, and smaller number of microorganisms. The application of silicon dioxide coating on acrylic resin appears to be a promising alternative, and its use can help in reducing the adhesion of Ca in prostheses.


Assuntos
Candida albicans , Propriedades de Superfície , Resinas Acrílicas , Dióxido de Silício , Bases de Dentadura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA