Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 528
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Rev Med Virol ; 34(2): e2525, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38375981

RESUMO

Blood transfusion is a vital procedure, where transfusion-transmitted infection of hepatitis B virus (HBV) remains an important issue, especially from blood donors with occult hepatitis B virus infection (OBI). Occult hepatitis B virus infection is a complex entity to detect using surrogate blood biomarkers for intrahepatic viral transcriptional activity, requiring a continually refined battery of tests utilised for screening. This review aims to critically evaluate the latest advances in the current blood biomarkers to guide the identification of OBI donors and discuss novel HBV markers that could be introduced in future diagnostic practice. Challenges in detecting low HBV surface antigen levels, mutants, and complexes necessitate ultrasensitive multivalent dissociation assays, whilst HBV DNA testing requires improved sensitivity but worsens inaccessibility. Anti-core antibody assays defer almost all potentially infectious donations but have low specificity, and titres of anti-surface antibodies that prevent infectivity are poorly defined with suboptimal sensitivity. The challenges associated with these traditional blood HBV markers create an urgent need for alternative biomarkers that would help us better understand the OBI. Emerging viral biomarkers, such as pre-genomic RNA and HBV core-related antigen, immunological HBV biomarkers of T-cell reactivity and cytokine levels, and host biomarkers of microRNA and human leucocyte antigen molecules, present potential advances to gauge intrahepatic activity more accurately. Further studies on these markers may uncover an optimal diagnostic algorithm for OBI using quantification of various novel and traditional blood HBV markers. Addressing critical knowledge gaps identified in this review would decrease the residual risk of transfusion-transmitted HBV infection without compromising the sustainability of blood supplies.


Assuntos
Hepatite B Crônica , Hepatite B , Humanos , Vírus da Hepatite B/genética , Anticorpos Anti-Hepatite B , Transfusão de Sangue , Antígenos do Núcleo do Vírus da Hepatite B , Doadores de Sangue , Biomarcadores , DNA Viral
2.
Emerg Infect Dis ; 30(9): 1819-1828, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39106464

RESUMO

During 2018-2021, eight septic transfusion reactions occurred from transfusion of platelet units contaminated with Acinetobacter spp., Staphylococcus saprophyticus, Leclercia adecarboxylata, or a combination of those environmental organisms. Whether biofilm formation contributed to evasion of bacterial risk mitigations, including bacterial culture, point-of-care testing, or pathogen-reduction technology, is unclear. We designed a 12-well plate-based method to evaluate environmental determinants of single-species and multispecies biofilm formation in platelets. We evaluated bacteria isolated from septic transfusion reactions for biofilm formation by using crystal violet staining and enumeration of adherent bacteria. Most combinations of bacteria had enhanced biofilm production compared with single bacteria. Combinations involving L. adecarboxylata had increased crystal violet biofilm production and adherent bacteria. This study demonstrates that transfusion-relevant bacteria can produce biofilms well together. More work is needed to clarify the effect of biofilms on platelet bacterial risk control strategies, but US Food and Drug Administration-recommended strategies remain acceptable.


Assuntos
Biofilmes , Plaquetas , Transfusão de Plaquetas , Biofilmes/crescimento & desenvolvimento , Humanos , Transfusão de Plaquetas/efeitos adversos , Plaquetas/microbiologia , Bactérias/isolamento & purificação , Reação Transfusional
3.
Emerg Infect Dis ; 30(5): 934-940, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38666600

RESUMO

To determine the kinetics of hepatitis E virus (HEV) in asymptomatic persons and to evaluate viral load doubling time and half-life, we retrospectively tested samples retained from 32 HEV RNA-positive asymptomatic blood donors in Germany. Close-meshed monitoring of viral load and seroconversion in intervals of ≈4 days provided more information about the kinetics of asymptomatic HEV infections. We determined that a typical median infection began with PCR-detectable viremia at 36 days and a maximum viral load of 2.0 × 104 IU/mL. Viremia doubled in 2.4 days and had a half-life of 1.6 days. HEV IgM started to rise on about day 33 and peaked on day 36; IgG started to rise on about day 32 and peaked on day 53. Although HEV IgG titers remained stable, IgM titers became undetectable in 40% of donors. Knowledge of the dynamics of HEV viremia is useful for assessing the risk for transfusion-transmitted hepatitis E.


Assuntos
Doadores de Sangue , Vírus da Hepatite E , Hepatite E , RNA Viral , Carga Viral , Viremia , Humanos , Hepatite E/epidemiologia , Hepatite E/virologia , Vírus da Hepatite E/genética , Vírus da Hepatite E/imunologia , Masculino , Adulto , Imunoglobulina M/sangue , Feminino , Imunoglobulina G/sangue , Cinética , Pessoa de Meia-Idade , Infecções Assintomáticas/epidemiologia , Estudos Retrospectivos , Anticorpos Anti-Hepatite/sangue , Alemanha/epidemiologia , Adulto Jovem
4.
Emerg Infect Dis ; 30(8): 1621-1630, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38981189

RESUMO

Nucleocapsid antibody assays can be used to estimate SARS-CoV-2 infection prevalence in regions implementing spike-based COVID-19 vaccines. However, poor sensitivity of nucleocapsid antibody assays in detecting infection after vaccination has been reported. We derived a lower cutoff for identifying previous infections in a large blood donor cohort (N = 142,599) by using the Ortho VITROS Anti-SARS-CoV-2 Total-N Antibody assay, improving sensitivity while maintaining specificity >98%. We validated sensitivity in samples donated after self-reported swab-confirmed infections diagnoses. Sensitivity for first infections in unvaccinated donors was 98.1% (95% CI 98.0-98.2) and for infection after vaccination was 95.6% (95% CI 95.6-95.7) based on the standard cutoff. Regression analysis showed sensitivity was reduced in the Delta compared with Omicron period, in older donors, in asymptomatic infections, <30 days after infection, and for infection after vaccination. The standard Ortho N antibody threshold demonstrated good sensitivity, which was modestly improved with the revised cutoff.


Assuntos
Anticorpos Antivirais , Doadores de Sangue , Vacinas contra COVID-19 , COVID-19 , SARS-CoV-2 , Humanos , COVID-19/imunologia , COVID-19/prevenção & controle , COVID-19/epidemiologia , SARS-CoV-2/imunologia , Anticorpos Antivirais/sangue , Anticorpos Antivirais/imunologia , Adulto , Pessoa de Meia-Idade , Masculino , Vacinas contra COVID-19/imunologia , Feminino , Vacinação , Adulto Jovem , Sensibilidade e Especificidade , Adolescente , Idoso , Nucleocapsídeo/imunologia , Teste Sorológico para COVID-19/métodos
5.
Transfusion ; 64(8): 1503-1508, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38877832

RESUMO

BACKGROUND: The large dengue (DENV) and chikungunya (CHIKV) outbreaks observed during the last decade across the world, as well as local transmissions in non-endemic areas are a growing concern for blood safety. The aim of this study was to evaluate and compare the sensitivity of nucleic acid tests (NAT) detecting DENV and CHIKV RNA. MATERIALS AND METHODS: Using DENV 1 to 4 International Standards, the limits of detection (LODs) calculated by probit analysis of two NAT assays; the cobas CHIKV/DENV assay (Roche Diagnostics) and the Procleix Dengue Virus Assay (Grifols) were compared. In addition, CHIKV-RNA LOD of the cobas CHIKV/DENV assay was evaluated. RESULTS: For dengue, the 95% LOD of the cobas assay ranged between 4.10 [CI95%: 2.70-8.19] IU/mL (DENV-2) and 7.07 [CI95%: 4.34-14.89] IU/mL (DENV-4), and between 2.19 [CI95%: 1.53-3.83] IU/mL (DENV-3) and 5.84 [CI95%: 3.84-10.77] IU/mL (DENV-1) for Procleix assay. The Procleix assay had a significant lower LOD for DENV-3 (2.19 vs. 5.89 IU/mL) when compared to the cobas assay (p = 0.005). The 95% LOD for CHIKV-RNA detection of the cobas assay was 4.76 [CI95%: 3.08-8.94] IU/mL. DISCUSSION: The two NAT assays developed for blood donor screening evaluated in this study demonstrated high and similar analytical performance. Subject to an appropriate risk-benefit assessment, they can be used to support blood safety during outbreaks in endemic areas or in non-endemic areas as an alternative to deferring blood donors during local transmission likely to affect the blood supply. The development of multiplex assays is expected to optimize laboratory organization.


Assuntos
Febre de Chikungunya , Vírus Chikungunya , Vírus da Dengue , Dengue , RNA Viral , Humanos , Dengue/transmissão , Dengue/diagnóstico , Dengue/prevenção & controle , Dengue/sangue , Febre de Chikungunya/diagnóstico , Febre de Chikungunya/transmissão , Febre de Chikungunya/sangue , Febre de Chikungunya/prevenção & controle , RNA Viral/sangue , RNA Viral/análise , Técnicas de Amplificação de Ácido Nucleico/métodos , Segurança do Sangue/métodos , Transfusão de Sangue , Sensibilidade e Especificidade , Limite de Detecção
6.
Transfusion ; 64(2): 325-333, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38180267

RESUMO

BACKGROUND: HIV, HBV, and HCV infections for ~60% of the US blood supply are monitored by TTIMS with syphilis added in 2020. STUDY DESIGN AND METHODS: Data were compiled from October 2020 to September 2022. Syphilis prevalence was estimated for allogeneic and directed donors who were consensus positive (CP) and the subset of those with confirmed-active infections (AI). Prevalence and incidence were stratified by demographics for two consecutive 1-year periods, starting October 1, 2020 and for both years combined. Incidence was estimated for repeat donors. Associations between syphilis positivity and other infections were evaluated. RESULTS: Among 14.75 million donations, syphilis prevalence was 28.4/100,000 donations and significantly higher during the second year compared to the first year. Overall, syphilis incidence for the two-year period was 10.8/100,000 person-years. The adjusted odds of a CP infection were 1.18 (95% CI: 1.11, 1.26) times higher in the second year compared to the first, and for AI, 1.22 (95% CI: 1.10, 1.35) times higher in year 2. Highest rates occurred among males, first-time, Black, and younger (ages 18-39) donors, and those in the South US Census region. Syphilis CP donors were 64 (95% CI: 46, 89) times more likely to be HIV CP, and AI donors 77 (95% CI: 52, 114) times more likely to be HIV CP than non-CP donors, when controlling for confounders. SUMMARY/CONCLUSIONS: Syphilis prevalence increased over the study period mirroring national trends reported by CDC and is significantly associated with HIV CP.


Assuntos
Infecções por HIV , Sífilis , Masculino , Humanos , Sífilis/epidemiologia , Estudos Soroepidemiológicos , Incidência , Doadores de Sangue , Infecções por HIV/epidemiologia , Prevalência
7.
Transfusion ; 64(3): 501-509, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38258881

RESUMO

BACKGROUND: Transfusion-transmitted malaria (TTM) is a public health problem in endemic and nonendemic areas. The Brazilian Ministry of Health (MH) requested the development of a nucleic acid amplification test (NAT) for the detection of Plasmodium spp. in public blood centers to increase blood safety. STUDY DESIGN AND METHODS: The new Brazilian NAT kit named NAT PLUS HIV/HBV/HCV/Malaria Bio-Manguinhos was first implemented in HEMORIO, a public blood center in the city of Rio de Janeiro. Since October 1, 2022, this blood center has been testing all its blood donations for malaria in a pool of six plasma samples to detect Plasmodium spp. by real-time polymerase chain reaction (PCR). RESULTS: Since the implementation of the NAT PLUS platform until February 2023, HEMORIO has successfully received and tested 200,277 donations. The platform detected two asymptomatic donors in the city of Rio de Janeiro, which is a nonendemic region for malaria. Our analyses suggested a malaria from the Amazon region caused by Plasmodium vivax, in the first case, while an autochthonous transmission case by Plasmodium malariae was identified in the rural area of Rio de Janeiro state. DISCUSSION: The NAT PLUS platform detects Plasmodium spp. in plasma samples with sensitivity capable of detecting subpatent infections. This is the first time worldwide that a group developed and implemented molecular diagnosis for Plasmodium spp. to be used by public blood centers to avoid TTM.


Assuntos
Infecções por HIV , Hepatite C , Malária , Humanos , Vírus da Hepatite B , Doadores de Sangue , Brasil/epidemiologia , Malária/diagnóstico , Malária/epidemiologia , Plasmodium malariae , Infecções por HIV/diagnóstico , Infecções por HIV/epidemiologia
8.
Transfusion ; 2024 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-39126400

RESUMO

BACKGROUND: Combining pathogen reduction technology (PRT) with blood screening may alleviate concerns over the risk of transfusion-transmitted infections (TTI) and support changes in blood donor selection to potentially increase blood availability. This study aimed to estimate the residual risk of human immunodeficiency virus (HIV), hepatitis B virus (HBV), and hepatitis C virus (HCV) transfusion-transmission in Canada after implementing PRT, while eliminating deferrals for sexual risk behaviors. STUDY DESIGN AND METHODS: A probabilistic approach that combined Bayesian networks with Monte Carlo simulations was used to estimate the risk of transfusing HIV-, HBV-, or HCV-contaminated blood components. Different scenarios were considered to compare the current residual risk after PRT implementation, with and without donor deferral criteria for sexual risk behaviors. Donor profiles and blood component outcomes were simulated based on a literature review including the prevalence and incidence of HIV, HBV, and HCV in the Canadian blood donor population; the use of current blood screening assays; and HIV, HBV, and HCV blood donor viral loads. RESULTS: In the universal PRT scenario (i.e., with PRT/without deferral criteria), the estimated risks of HIV, HBV, and HCV transmission were significantly lower than those in the currently observed scenario (i.e., without PRT/with deferral criteria). CONCLUSIONS: This risk model suggests that PRT for platelets and plasma (and eventually for RBCs when available) significantly reduces the residual risks of HIV, HBV and HCV transfusion-transmission and could enable the removal of blood donor deferral criteria for sexual risk behaviors.

9.
Vox Sang ; 2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38889998

RESUMO

BACKGROUND AND OBJECTIVES: Haemovigilance (HV) systems aim to improve transfusion outcomes in patients and donor safety. An important question for blood regulators is how to ensure an effective HV system. MATERIALS AND METHODS: We retrospectively analysed the HV reports submitted to Paul-Ehrlich-Institut over the last two decades. RESULTS: Between 2011 and 2020, 50.86 million units of blood components were used, and 8931 suspected serious donor and recipient adverse reactions (SARs), 874 serious adverse events (SAEs) and 12,073 donor look-backs were reported. Following implementation of specific risk-minimization measures (RMMs) between 2000 and 2010, SAR reporting rates decreased for transfusion-transmitted viral infections (TTVIs), transfusion-related acute lung injury (TRALI) and transfusion-transmitted bacterial infections (TTBIs), while increasing for other serious adverse transfusion reactions. Within this decade, the overall blood component use decreased. CONCLUSION: Long-term data collection forms the basis to establish trends and changes in reporting and to evaluate the effect of RMM. Standardized criteria for reaction types, seriousness and imputability assessments and availability of a denominator are important elements. Central data collection and independent assessment allow for monitoring HV data in a nationwide context over time. Stakeholder involvement and transparent feedback on the benefit of RMM will help to achieve the objectives of HV.

10.
Vox Sang ; 2024 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-39048116

RESUMO

BACKGROUND AND OBJECTIVES: To reduce the risk of transfusion-transmitted malaria (TTM) from transfusible components, Australia tests for malaria antibodies in both travellers returning from and former residents of malaria-endemic areas. The testing is performed a minimum of 120 days after last potential exposure. TTM is an extremely rare event and managing the risk adds considerable complexity. The objectives of this study were to analyse various testing and deferral strategies, considering the risk, donation numbers and operational complexities. MATERIALS AND METHODS: A residual risk model was developed to calculate the risk of TTM in five testing/deferral strategies. Australian blood donor data from 2020 and 2021 were used and incorporated the incidence of parasitaemia, Plasmodium species and the malaria enzyme immunoassay test's failure rate. Donor and donation loss or gain and an operational assessment were performed. RESULTS: The current model's estimated risk of TTM is 1 in 67.9 million transfused units. Testing residents with a 120-day plasma restriction for visitors without testing was found to have the same estimated risk, with an expected increase of 342 donations per year, significant cost savings and a 62% reduction in the number of donors requiring assessment. CONCLUSION: A strategy that involves testing residents of malaria areas only and a 120-day plasma travel restriction would not significantly increase the risk of TTM, is operationally simpler, costs less and results in a small increase in donations.

11.
Vox Sang ; 2024 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-39048114

RESUMO

BACKGROUND AND OBJECTIVES: The risk of transfusion-transmitted malaria (TTM) infections is extremely low in Australia, and the cost-effectiveness of the current screening strategy has not been assessed. This study aims to conduct a cost-effectiveness analysis of different malaria screening strategies in blood donors as part of the risk-based decision-making framework. MATERIALS AND METHODS: A decision tree model was developed to assess the cost-effectiveness of five alternative malaria screening strategies from a healthcare sector perspective. Screening strategies combining total or partial removal of malaria testing with different deferral periods were considered. The probabilities of developing severe and uncomplicated TTM were based on a literature review of cases in non-endemic areas since 2000. The health outcomes were quantified using disability-adjusted life years. The costs of non-returning donors due to deferral were also included. Deterministic and probabilistic sensitivity analyses were conducted to account for data uncertainty. RESULTS: The residual risks for all strategies were so low that the costs, mortality and morbidity associated with TTM are almost negligible. The overall costs were predominantly influenced by the costs of non-returning blood donors. As a result, removal of malaria testing and applying a 28-day deferral for at-risk donors were the least costly and most cost-effective of all the options considered. CONCLUSION: The current screening strategy for malaria in blood donors in Australia is not an efficient use of healthcare resources. Partial or total removal of malaria testing would bring significant cost savings without significantly compromising blood safety.

12.
Vox Sang ; 119(8): 834-841, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38754952

RESUMO

BACKGROUND AND OBJECTIVES: Blood safety measures used by blood establishments to increase blood component safety can be validated using Transfusion-Relevant Bacterial Reference Strains (TRBRS). Ultra-cold storage conditions and manual preparation of the current TRBRS may restrict their practical use. To address this issue, the ISBT Transfusion-Transmitted Infectious Diseases Working Party's Bacterial Subgroup organized an international study to validate TRBRS in a user-friendly, lyophilised format. MATERIALS AND METHODS: Two bacterial strains Klebsiella pneumoniae PEI-B-P-08 and Staphylococcus aureus PEI-B-P-63 were manufactured as lyophilised material. The lyophilised bacteria were distributed to 11 different labs worldwide to assess the robustness for enumeration, identification and determination of growth kinetics in platelet concentrates (PCs). RESULTS: Production of lyophilised TRBRS had no impact on the growth properties compared with the traditional format. The new format allows a direct low-quantity spiking of approximately 30 bacteria in PCs for transfusion-relevant experiments. In addition, the lyophilised bacteria exhibit long-term stability across a broad temperature range and can even be directly rehydrated in PCs without losing viability. Interlaboratory comparative study demonstrated the robustness of the new format as 100% of spiked PC exhibited growth. CONCLUSION: Lyophilised TRBRS provide a user-friendly material for transfusion-related studies. TRBRS in the new format have improved features that may lead to a more frequent use in the quality control of transfusion-related safety measures in the future.


Assuntos
Liofilização , Klebsiella pneumoniae , Staphylococcus aureus , Liofilização/métodos , Humanos , Staphylococcus aureus/crescimento & desenvolvimento , Klebsiella pneumoniae/crescimento & desenvolvimento , Segurança do Sangue/métodos , Transfusão de Sangue/métodos , Transfusão de Sangue/normas , Plaquetas/microbiologia , Padrões de Referência , Preservação de Sangue/métodos
13.
Vox Sang ; 119(8): 851-858, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38858164

RESUMO

BACKGROUND AND OBJECTIVES: A plasma transfusion dose should be weight-based (10-20 mL/kg), which equates to three to four units in an average-sized adult; therefore, the transfusion of single units under most circumstances is sub-therapeutic. MATERIALS AND METHODS: This retrospective observational study examined the prevalence of single-unit plasma transfusion in adults within a 12-hospital system from 1 January 2018, to 31 December 2019. RESULTS: During the study period, 5791 patients received plasma transfusions. The overall prevalence of single-unit plasma was 17.1% for 988 patients. The majority, 3047 (52.6%), occurred at one hospital, 2132 (36.9%) among five hospitals and 612 (10.7%) at the remaining six hospitals. Cardiac and gastrointestinal (GI)/transplant transfused 2707 (46.8%), combined respiratory, neurological, orthopaedic and congenital/dermatology/other comprised 2133 (36.9%) of the six hospitals that transfused less than 200 patients, four (66.7%) transfused single units above the overall prevalence. CONCLUSION: In this hospital system, more than one in six patients received a transfusion of a single plasma unit. Six of the 12 hospitals had 89.5% of the patients who were transfused plasma. Six service lines transfused 83.7% of all patients receiving plasma. Hospitals that infrequently transfused plasma were more likely to under-dose.


Assuntos
Transfusão de Componentes Sanguíneos , Plasma , Humanos , Estudos Retrospectivos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade
14.
Vox Sang ; 2024 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-39048115

RESUMO

BACKGROUND AND OBJECTIVES: Plasmodium species are naturally transmitted by Anopheles mosquitos. The parasite infects red blood cells (RBCs) and can be transfused with blood products. In non-endemic areas, the main risk of infection arises from travellers coming back and people immigrating from malaria-endemic regions. Endemic countries face a permanent risk of infection from transfusion-transmitted malaria (TTM). TTM may cause life-threatening complications in patients dependent on blood donations. This study aimed to investigate the efficacy of Plasmodium falciparum inactivation in RBC units by treatment with short-wavelength ultraviolet C (UVC) light in the absence of photochemical additives. MATERIALS AND METHODS: RBC units were spiked with P. falciparum to a parasite density of 0.1%-1% and irradiated with up to 4.5 J/cm2 UVC. The parasite density of UVC-treated dilution series and untreated controls were compared over 3 weeks after irradiation. RESULTS: The lowest dose of 1.5 J/cm2 UVC led to a 3.1 log reduction in parasite load compared with the untreated control. The inactivation capacity was dose-dependent. Strikingly, 4.5 J/cm2 led to ≥5.3 log unit reduction, which was equivalent to a complete inactivation in two out of three experiments. CONCLUSION: Pathogen reduction with UVC light was previously shown to be effective for different bacteria and viruses, but the inactivation of parasites in RBC concentrates was not addressed until now. The present study provides evidence for significant inactivation of P. falciparum-infected RBCs by UVC light.

15.
Vox Sang ; 119(8): 821-826, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38946160

RESUMO

BACKGROUND AND OBJECTIVES: The detection of treponemal antibodies, which are used to make a diagnosis of syphilis, is important both for diagnostic purposes and as a mandatory blood donor test in most countries. We evaluated the feasibility of using Kode Technology to make syphilis peptide red cell kodecytes for use in column agglutination serologic platforms. MATERIALS AND METHODS: Candidate Kode Technology function-spacer-lipid (FSL) constructs were made for the Treponema pallidum lipoprotein (TmpA) of T. pallidum, using the peptide and FSL selection algorithms, and then used to make kodecytes. Developmental kodecytes were evaluated against a large range of syphilis antibody reactive and non-reactive samples in column agglutination platforms and compared against established methodologies. Overall, 150 reactive and 2072 non-reactive Syphicheck assay (a modified T. pallidum particle agglutination) blood donor samples were used to evaluate the agreement rate of the developed kodecyte assay. RESULTS: From three FSL-peptide candidate constructs, one was found to be the most suitable for diagnostics. Of 150 Syphicheck assay reactive samples, 146 were TmpA-kodecyte reactive (97.3% agreement), compared with 58.0% with the rapid plasmin reagin (RPR) assay for the same samples. Against the 2072 expected syphilis non-reactive samples the agreement rate for TmpA-kodecytes was 98.8%. CONCLUSION: TmpA-kodecytes are viable for use as cost-effective serologic reagent red cells for the detection of treponemal antibodies to diagnose syphilis with a high level of specificity in blood centres. This kodecyte methodology also potentially allows for introduction of the reverse-algorithm testing into low-volume laboratories, by utilizing existing transfusion laboratory infrastructure.


Assuntos
Antígenos de Bactérias , Lipoproteínas , Sífilis , Treponema pallidum , Humanos , Treponema pallidum/imunologia , Sífilis/diagnóstico , Sífilis/sangue , Lipoproteínas/imunologia , Antígenos de Bactérias/imunologia , Eritrócitos/microbiologia , Testes de Aglutinação/métodos , Sorodiagnóstico da Sífilis/métodos , Anticorpos Antibacterianos/sangue
16.
Vox Sang ; 119(3): 252-256, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38245853

RESUMO

BACKGROUND AND OBJECTIVES: Transfusion-related hepatitis B infections have been reduced significantly with the implementation of blood screening using both serology and nucleic acid amplification technology (NAT) in developed countries. However, in resource-constrained countries, where NAT is inaccessible, the risk persists from early acute and occult cases. This study aimed to determine the antibodies to hepatitis B core antigen (anti-HBc) reactive rate among hepatitis B surface antigen (HBsAg)-screened negative blood donors and its impact on blood safety in the Philippines. MATERIALS AND METHODS: A total of 1602 HBsAg-negative samples, randomly collected from nine leading blood service facilities representative of each region in the Philippines, were tested for anti-HBc immunoglobulin M (IgM), Total and antibodies to HBsAg (anti-HBs) using the Architect i2000SR Immunoassay Analyser (Abbott Laboratories, IL). Anti-HBc IgM and/or Total repeat reactive were further tested for hepatitis B virus (HBV) NAT using the Cobas TaqScreen MPX v2.0 (Roche Diagnostics, Basel). RESULTS: Overall, 19.16% HBsAg-negative samples (n = 307/1602) were reactive for either anti-HBc IgM or Total or a combination of both, of which 1.3% (n = 4/307) had detectable HBV-DNA and 80.5% (n = 247/307) were anti-HBs positive. About the anti-HBs titres, 30.27% (n = 485/1602) were positive (≥10 IU/L) with 55.67% (n = 270/485) having titres ≥100 IU/L. Anti-HBs-only-positive samples were 14.85% (n = 238/1602). CONCLUSION: We observed a high anti-HBc reactive rate (19.16%) with 3.7% anti-HBc-only reactive (anti-HBs negative) and 1.3% HBV-DNA positive. This warrants the need to reconsider existing screening practices to improve blood safety in the country.


Assuntos
Antígenos do Núcleo do Vírus da Hepatite B , Hepatite B , Humanos , Antígenos de Superfície da Hepatite B , Segurança do Sangue , Doadores de Sangue , DNA Viral , Vírus da Hepatite B/genética , Anticorpos Anti-Hepatite B , Hepatite B/diagnóstico , Imunoglobulina M
17.
Transfus Apher Sci ; 63(4): 103963, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38968755

RESUMO

BACKGROUND: Immunohematology tests are crucial in transfusion safety. This study aimed to assess irregular red blood cell (RBC) antibodies, abnormal hemoglobin and dangerous universal blood donors at a public blood center in a Brazilian metropolitan area. METHODS: A cross-sectional study included all consecutive blood donors from January 2018 to December 2021 at the Brasília Blood Center Foundation, Federal District (FD), Brazil. RESULTS: Among 205,965 blood donations, irregular RBC antibodies were found in 743 (0.4 %). Abnormal hemoglobin was observed in 5396 (2.6 %): 3959 (1.9 %) with Hb AS, 1344 (0.7 %) with Hb AC, and 93 (< 0,1 %) with other hemoglobin variants. Of O group donors, 12.5 % (9646) had hemolysins: 12.5 % (2410) both anti-A and anti-B, 8.7 % (9646) only anti-A, and 1.6 % (1763) only anti-B hemolysins. Female sex (p < 0.001) and increasing age (p < 0.001) were associated with irregular RBC antibodies. O and/or Rh(D)-positive blood groups had a lower prevalence of irregular RBC antibodies compared to other ABO and/or Rh(D)-negative groups. Age (p < 0.001) and female sex (p < 0.001) were associated with anti-A/anti-B hemolysins, while FD residency was associated with reduced incidence (p < 0.001). CONCLUSION: Anti-A/anti-B hemolysins in O group donors, abnormal hemoglobin and irregular RBC antibodies pose risks to transfusion practice and should not be overlooked. Advancing age, female sex, ABO blood group other than O, or Rh(D)- negative are independently associated with the presence of irregular RBC antibodies. Dangerous universal blood donors were associated with advanced age, female gender, Rh(D)-positive blood type, and individuals residing in a Brazilian state other than where the blood center was located.


Assuntos
Doadores de Sangue , Eritrócitos , Humanos , Brasil , Feminino , Masculino , Estudos Transversais , Adulto , Pessoa de Meia-Idade , Eritrócitos/imunologia , Hemoglobinas/análise , Adolescente , Adulto Jovem , Bancos de Sangue
18.
Euro Surveill ; 29(24)2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38873797

RESUMO

BackgroundAwareness of transfusion-transmitted hepatitis E raised in recent years led to the mandatory testing of blood donations in some European countries for hepatitis E virus (HEV) RNA. However, little is known about the epidemiology of HEV infections.AimTo and describe and analyse the epidemiology of HEV infections in blood donors in Germany.MethodsData from routine testing of therapeutic blood products donated between January 2015 and December 2022 at the Uni.Blutspendedienst OWL were analysed at the Institute of Laboratory and Transfusion Medicine, Heart and Diabetes Centre North Rhine-Westphalia. A total of 731,630 allogenic blood donations from 119,610 individual blood donors were tested for HEV RNA in minipools of 96 samples. The HEV RNA-positive donations were analysed for the presence of anti-HEV IgM and IgG. The HEV strains were genotyped and various clinical liver-specific parameters were determined.ResultsA total of 497 HEV-positive blood donations were identified, resulting in a yearly incidence of 1:1,474, from which 78.4% of the donations were RNA-only positive. Increased alanine aminotransferase activity was determined in 26.6% of HEV RNA-positive donors and was associated with the detection of IgG antibodies (1.2% anti-HEV IgM-positive, 11.9% anti-HEV IgM- and IgG-positive and 8.5% anti-HEV IgG-positive). An average incidence of 0.084-0.083% HEV RNA-positive donations in June and July in all years was observed, and a higher proportion of HEV RNA-positive men compared with women. All isolated HEV sequences corresponded to genotype 3.ConclusionOur results underline the necessity of HEV RNA screening in blood donations.


Assuntos
Hepatite E , Hepatite E/sangue , Hepatite E/epidemiologia , Alemanha/epidemiologia , Doadores de Sangue/estatística & dados numéricos , Doação de Sangue/estatística & dados numéricos , Transfusão de Sangue/estatística & dados numéricos , Humanos , Masculino , Feminino , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , RNA , Imunoglobulina M , Imunoglobulina G , Fígado/metabolismo
19.
Transfus Med Hemother ; 51(3): 185-192, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38867811

RESUMO

Introduction: Evorpacept is a CD47-blocking agent currently being developed for the treatment of various cancers. Interference by evorpacept in pretransfusion compatibility testing has been reported at limited plasma concentrations. Although various mitigation strategies have been proposed, none are practical. This in vitro study assessed evorpacept-induced interference at extended concentrations and investigated the capability of a novel mitigation agent, Evo-NR. Methods: Antibody screening tests were performed on evorpacept-spiked plasma with (anti-E and anti-Jka) or without alloantibodies at evorpacept concentrations up to 2,000 µg/mL using manual gel cards and automated analyzers. Evorpacept-coated red blood cells (RBCs) (rr [ce/ce], Fy[a+b-], S-s+) were tested by direct antiglobulin testing (DAT) and antigen typing using anti-Fyb and anti-S reagents at indirect antiglobulin testing (IAT) phase. Evo-NR was used to resolve the interference in plasma and RBC samples. Flow cytometry was used to assess the mitigation effects. Results: Evorpacept-spiked plasma showed panreactive interference in antibody screening tests using manual gel cards (2+ to 3+) and automated analyzers (4+). A carryover effect was also observed in the automated analyzers. The use of a 3- to 6-fold molar excess of Evo-NR effectively resolved the interference in the plasma and enabled accurate alloantibody identification. Although the reduction in evorpacept binding to RBCs was identified via flow cytometry, Evo-NR was incapable of resolving the serologic interference observed in DAT and antigen typing at IAT phase. Discussion: Evorpacept showed constant panreactivity and a carryover effect at high concentrations. Evo-NR successfully resolved the interference in the plasma samples and could be considered a practical and efficient mitigation solution. Implementation of Evo-NR has the potential to support RBC transfusion for patients undergoing evorpacept treatment.

20.
Emerg Infect Dis ; 29(10): 1979-1989, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37561399

RESUMO

During May 2018‒December 2022, we reviewed transfusion-transmitted sepsis cases in the United States attributable to polymicrobial contaminated apheresis platelet components, including Acinetobacter calcoaceticus‒baumannii complex or Staphylococcus saprophyticus isolated from patients and components. Transfused platelet components underwent bacterial risk control strategies (primary culture, pathogen reduction or primary culture, and secondary rapid test) before transfusion. Environmental samples were collected from a platelet collection set manufacturing facility. Seven sepsis cases from 6 platelet donations from 6 different donors were identified in patients from 6 states; 3 patients died. Cultures identified Acinetobacter calcoaceticus‒baumannii complex in 6 patients and 6 transfused platelets, S. saprophyticus in 4 patients and 4 transfused platelets. Whole-genome sequencing showed environmental isolates from the manufacturer were closely related genetically to patient and platelet isolates, indicating the manufacturer was the most probable source of recurrent polymicrobial contamination. Clinicians should maintain awareness of possible transfusion-transmitted sepsis even when using bacterial risk control strategies.


Assuntos
Plaquetas , Sepse , Humanos , Estados Unidos/epidemiologia , Transfusão de Plaquetas/efeitos adversos , Sepse/epidemiologia , Sepse/etiologia , Transfusão de Sangue , Bactérias/genética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA