Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.976
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38485057

RESUMO

BACKGROUND: MUPPITS-2 was a randomized, placebo-controlled clinical trial that demonstrated mepolizumab (anti-IL-5) reduced exacerbations and blood and airway eosinophils in urban children with severe eosinophilic asthma. Despite this reduction in eosinophilia, exacerbation risk persisted in certain patients treated with mepolizumab. This raises the possibility that subpopulations of airway eosinophils exist that contribute to breakthrough exacerbations. OBJECTIVE: We aimed to determine the effect of mepolizumab on airway eosinophils in childhood asthma. METHODS: Sputum samples were obtained from 53 MUPPITS-2 participants. Airway eosinophils were characterized using mass cytometry and grouped into subpopulations using unsupervised clustering analyses of 38 surface and intracellular markers. Differences in frequency and immunophenotype of sputum eosinophil subpopulations were assessed based on treatment arm and frequency of exacerbations. RESULTS: Median sputum eosinophils were significantly lower among participants treated with mepolizumab compared with placebo (58% lower, 0.35% difference [95% CI 0.01, 0.74], P = .04). Clustering analysis identified 3 subpopulations of sputum eosinophils with varied expression of CD62L. CD62Lint and CD62Lhi eosinophils exhibited significantly elevated activation marker and eosinophil peroxidase expression, respectively. In mepolizumab-treated participants, CD62Lint and CD62Lhi eosinophils were more abundant in participants who experienced exacerbations than in those who did not (100% higher for CD62Lint, 0.04% difference [95% CI 0.0, 0.13], P = .04; 93% higher for CD62Lhi, 0.21% difference [95% CI 0.0, 0.77], P = .04). CONCLUSIONS: Children with eosinophilic asthma treated with mepolizumab had significantly lower sputum eosinophils. However, CD62Lint and CD62Lhi eosinophils were significantly elevated in children on mepolizumab who had exacerbations, suggesting that eosinophil subpopulations exist that contribute to exacerbations despite anti-IL-5 treatment.

2.
J Allergy Clin Immunol ; 153(4): 988-997.e11, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38081546

RESUMO

BACKGROUND: Thymic stromal lymphopoietin (TSLP) is released from the airway epithelium in response to various environmental triggers, inducing a type-2 inflammatory response, and is associated with airway inflammation, airway hyperresponsiveness (AHR), and exacerbations. TSLP may also induce AHR via a direct effect on airway smooth muscle and mast cells, independently of type-2 inflammation, although association between airway TSLP and AHR across asthma phenotypes has been described sparsely. OBJECTIVES: This study sought to investigate the association between AHR and levels of TSLP in serum, sputum, and bronchoalveolar lavage in patients with asthma with and without type-2 inflammation. METHODS: A novel ultrasensitive assay was used to measure levels of TSLP in patients with asthma (serum, n = 182; sputum, n = 81; bronchoalveolar lavage, n = 85) and healthy controls (serum, n = 47). The distribution and association among airway and systemic TSLP, measures of AHR, type-2 inflammation, and severity of disease were assessed. RESULTS: TSLP in sputum was associated with AHR independently of levels of eosinophils and fractional exhaled nitric oxide (ρ = 0.49, P = .005). Serum TSLP was higher in both eosinophil-high and eosinophil-low asthma compared to healthy controls: geometric mean: 1600 fg/mL (95% CI: 1468-1744 fg/mL) and 1294 fg/mL (95% CI: 1167-1435 fg/mL) versus 846 fg/mL (95% CI: 661-1082 fg/mL), but did not correlate with the level of AHR. Increasing age, male sex, and eosinophils in blood were associated with higher levels of TSLP in serum, whereas lung function, inhaled corticosteroid dose, and symptom score were not. CONCLUSIONS: The association between TSLP in sputum and AHR to mannitol irrespective of markers of type-2 inflammation further supports a role of TSLP in AHR that is partially independent of eosinophilic inflammation.


Assuntos
Asma , Eosinofilia , Inflamação , Linfopoietina do Estroma do Timo , Humanos , Masculino , Asma/diagnóstico , Asma/metabolismo , Citocinas , Eosinofilia/diagnóstico , Eosinofilia/metabolismo , Eosinófilos , Inflamação/diagnóstico , Inflamação/metabolismo , Escarro , Linfopoietina do Estroma do Timo/metabolismo
3.
Artigo em Inglês | MEDLINE | ID: mdl-38663815

RESUMO

BACKGROUND: The relative utility of eosinophil peroxidase (EPX) and blood and sputum eosinophil counts as disease biomarkers in asthma is uncertain. OBJECTIVE: We sought to determine the utility of EPX as a biomarker of systemic and airway eosinophilic inflammation in asthma. METHODS: EPX protein was measured by immunoassay in serum and sputum in 110 healthy controls to establish a normal reference range and in repeated samples of serum and sputum collected during 3 years of observation in 480 participants in the Severe Asthma Research Program 3. RESULTS: Over 3 years, EPX levels in patients with asthma were higher than normal in 27% to 31% of serum samples and 36% to 53% of sputum samples. Eosinophils and EPX correlated better in blood than in sputum (rs values of 0.74 and 0.43, respectively), and high sputum EPX levels occurred in 27% of participants with blood eosinophil counts less than 150 cells/µL and 42% of participants with blood eosinophil counts between 150 and 299 cells/µL. Patients with persistently high sputum EPX values for 3 years were characterized by severe airflow obstruction, frequent exacerbations, and high mucus plug scores. In 59 patients with asthma who started mepolizumab during observation, serum EPX levels normalized in 96% but sputum EPX normalized in only 49%. Lung function remained abnormal even when sputum EPX normalized. CONCLUSIONS: Serum EPX is a valid protein biomarker of systemic eosinophilic inflammation in asthma, and sputum EPX levels are a more sensitive biomarker of airway eosinophilic inflammation than sputum eosinophil counts. Eosinophil measures in blood frequently miss airway eosinophilic inflammation, and mepolizumab frequently fails to normalize airway eosinophilic inflammation even though it invariably normalizes systemic eosinophilic inflammation.

4.
J Infect Dis ; 229(1): 214-222, 2024 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-37369370

RESUMO

BACKGROUND: Inability to identify the microbial etiology of lower respiratory tract infection leads to unnecessary antibiotic use. We evaluated the utility of the BioFire FilmArray Pneumonia Panel (BioFire PN) to inform microbiologic diagnosis. METHODS: Hospitalized adults with respiratory illness were recruited; sputa and clinical/laboratory data were collected. Sputa were cultured for bacteria and tested with BioFire PN. Microbial etiology was adjudicated by 4 physicians. Bacterial polymerase chain reaction (PCR) was compared with culture and clinical adjudication. RESULTS: Of 298 sputa tested, BioFire PN detected significantly more pathogens (350 bacteria, 16 atypicals, and 164 viruses) than sputum culture plus any standard-of-care testing (91% vs 60%, P < .0001). When compared with culture, the sensitivity of BioFire PN for individual bacteria was 46% to 100%; specificity, 61% to 100%; and negative predictive value, 92% to 100%. Cases were adjudicated as viral (n = 58) and bacterial (n = 100). PCR detected bacteria in 55% of viral cases and 95% of bacterial (P < .0001). High serum procalcitonin and bacterial adjudication were more often associated with sputa with 106 or 107 copies detected. CONCLUSIONS: Multiplex PCR testing of sputa for bacteria is useful to rule out bacterial infection with added value to detect viruses and atypical bacteria.


Assuntos
Pneumonia , Infecções Respiratórias , Vírus , Adulto , Humanos , Bactérias/genética , Vírus/genética , Reação em Cadeia da Polimerase Multiplex , Pneumonia/diagnóstico
5.
J Infect Dis ; 2024 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-38836471

RESUMO

BACKGROUND: We determined the relationships between cytokine expression in sputum and clinical data to characterise and understand Chronic Obstructive Pulmonary Disease (COPD) exacerbations in COPD patients. METHODS: We measured 30 cytokines in 936 sputum samples, collected at stable state (ST) and exacerbation (EX) visits from 99 participants in the Acute Exacerbation and Respiratory InfectionS in COPD (AERIS) study (NCT01360398, www.clinicaltrials.gov). We determined their longitudinal expression and examined differential expression based on disease status or exacerbation type. RESULTS: Of the cytokines, 17 were suitable for analysis. As for disease states, in EX sputum samples, IL-17A, TNF-α, IL-1ß, and IL-10 were significantly increased compared to ST sputum samples, but a logistic mixed model could not predict disease state. As for exacerbation types, bacteria-associated exacerbations showed higher expression of IL-17A, TNF-α, IL-1ß, and IL-1α. IL-1α, IL-1ß, and TNF-α were identified as suitable biomarkers for bacteria-associated exacerbation. Bacteria-associated exacerbations also formed a cluster separate from other exacerbation types in principal component analysis. CONCLUSIONS: Measurement of cytokines in sputum from COPD patients could help identify bacteria-associated exacerbations based on increased concentrations of IL-1α, IL-1ß, or TNF-α. This finding may provide a point-of-care assessment to distinguish a bacterial exacerbation of COPD from other exacerbation types.

6.
Am J Physiol Lung Cell Mol Physiol ; 326(2): L125-L134, 2024 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-38084404

RESUMO

Cystic fibrosis-related diabetes (CFRD) affects 40%-50% of adults with CF and is associated with a decline in respiratory health. The microbial flora of the lung is known to change with the development of CF disease, but how CFRD affects the microbiome has not been described. We analyzed the microbiome in sputa from 14 people with CF, 14 with CFRD, and two who were classed as pre-CFRD by extracting DNA and amplifying the variable V3-V4 region of the microbial 16S ribosomal RNA gene by PCR. Sequences were analyzed and sources were identified to genus level. We found that the α-diversity of the microbiome using Shannon's diversity index was increased in CFRD compared with CF. Bray Curtis dissimilarity analysis showed that there was separation of the microbiomes in CF and CFRD sputa. The most abundant phyla identified in the sputum samples were Firmicutes and Proteobacteria, Actinobacteriota and Bacteroidota, and the ratio of Firmicutes/Bacteroidota was reduced in CFRD compared with CF. Pseudomonas, Azhorizophilus, Porphyromonas, and Actinobacillus were more abundant in CFRD compared with CF, whereas Staphylococcus was less abundant. The relative abundance of these genera did not correlate with age; some correlated with a decline in FEV1/FVC but all correlated with hemoglobin A1C (HbA1c) indicating that development of CFRD mediates further changes to the respiratory microbiome in CF.NEW & NOTEWORTHY Cystic fibrosis-related diabetes (CFRD) is associated with a decline in respiratory health. We show for the first time that there was a change in the sputum microbiome of people with CFRD compared with CF that correlated with markers of raised blood glucose.


Assuntos
Fibrose Cística , Diabetes Mellitus , Microbiota , Adulto , Humanos , Fibrose Cística/complicações , Fibrose Cística/microbiologia , Escarro , Pulmão/microbiologia
7.
J Clin Microbiol ; 62(4): e0166523, 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38501659

RESUMO

Many Legionella pneumonia patients do not produce sputum, and it is unknown whether purulent sputum is required for the identification of Legionella species. This study aimed to evaluate the identification rate of Legionella species based on sputum quality and the factors predictive of Legionella infection. This study included Legionella pneumonia patients at Kurashiki Central Hospital from November 2000 to December 2022. Sputum quality, based on gram staining, was classified as the following: Geckler 1/2, 3/6 and 4/5. Geckler 4/5 was defined as purulent sputum. The sputa of 104 of 124 Legionella pneumonia patients were cultured. Fifty-four patients (51.9%) were identified with Legionella species, most of which were Legionella pneumophila serogroup 1 (81.5%). The identification rates of Legionella species according to sputum quality were 57.1% (16/28) in Geckler 1/2 sputum, 50.0% (34/68) in Geckler 3/6 sputum, and 50.0% (4/8) in Geckler 4/5 sputum, which were not significantly different (P = 0.86). On multivariate analysis, pre-culture treatment with anti-Legionella antimicrobials (odds ratio [OR] 0.26, 95% confidence interval [CI] 0.06-0.91), Pneumonia Severity Index class ≥IV (OR 2.57 [95% CI 1.02-6.71]), and intensive care unit admission (OR 3.08, 95% CI 1.06-10.09) correlated with the ability to identify Legionella species, but sputum quality did not (OR 0.88, 95% CI 0.17-4.41). The identification rate of Legionella species in non-purulent sputum was similar to that in purulent sputum. For the diagnosis of Legionella pneumonia, sputum should be collected before administering anti-Legionella antibiotics and cultured regardless of sputum quality.


Assuntos
Legionella pneumophila , Legionella , Doença dos Legionários , Pneumonia , Humanos , Escarro , Doença dos Legionários/diagnóstico
8.
J Clin Microbiol ; 62(1): e0118323, 2024 01 17.
Artigo em Inglês | MEDLINE | ID: mdl-38112521

RESUMO

IMPORTANCE: Spacer oligonucleotide typing (spoligotyping), the first-line genotyping assay for Mycobacterium tuberculosis (MTB), plays a fundamental role in the investigation of its epidemiology and evolution. In this study, we established a single-tube spoligotyping assay using MeltArray, a highly multiplex polymerase chain reaction (PCR) approach that runs on a real-time PCR thermocycler. The MeltArray protocol included an internal positive control, gyrB, to indicate the abundance of MTB via the quantification cycle and 43 spacers to identify the spoligotype via melting curve analysis. The entire protocol was completed in a single step within 2.5 hours. The lowest detectable copy number for the tested strains was 20 copies/reaction and thus sufficient for analyzing both culture and sputum samples. We conclude that MeltArray-based spoligotyping could be used immediately in low- and middle-income countries with a high tuberculosis burden, given its easy access, improved throughput, and potential applicability to clinical samples.


Assuntos
Mycobacterium tuberculosis , Tuberculose , Humanos , Mycobacterium tuberculosis/genética , Tuberculose/microbiologia , Epidemiologia Molecular/métodos , Reação em Cadeia da Polimerase em Tempo Real , Reação em Cadeia da Polimerase Multiplex , Técnicas de Tipagem Bacteriana/métodos , Genótipo
9.
J Clin Microbiol ; 62(4): e0001924, 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38483169

RESUMO

Tongue dorsum swabbing is a potential alternative to sputum collection for tuberculosis (TB) testing. Previous studies showed that Cepheid Xpert MTB/RIF Ultra (Xpert Ultra) can detect Mycobacterium tuberculosis DNA on tongue swabs stored in buffer, with 72% sensitivity and 100% specificity relative to a sputum microbiological reference standard (sputum MRS). The present study evaluated a more convenient sample collection protocol (dry swab storage), combined with streamlined sample processing protocols, for evaluating two commercial TB diagnostic tests: Xpert Ultra and Molbio Truenat MTB Ultima (MTB Ultima). Copan FLOQSwabs were self-collected or collected by study workers from 321 participants in Western Cape, South Africa. All participants had symptoms suggestive of TB, and 245 of them had sputum MRS-confirmed TB (by sputum MGIT culture and/or Xpert Ultra). One tongue swab per participant was tested on Xpert Ultra, and another tongue swab was tested with MTB Ultima. Xpert Ultra was 75.5% sensitive and 100% specific relative to sputum MRS, similar to previous methods that used swabs stored in buffer. MTB Ultima was 71.6% sensitive and 96.9% specific relative to sputum MRS. When sample lysates that were false-negative or invalid by MTB Ultima were frozen, thawed, and re-tested, MTB Ultima sensitivity rose to 79.1%. Both tests were more sensitive with swabs from participants with higher sputum Xpert Ultra semi-quantitative results. Although additional development could improve diagnostic accuracy, these results further support tongue swabs as easy-to-collect samples for TB testing. IMPORTANCE: Tongue dorsum swabbing is a promising alternative to sputum collection for tuberculosis (TB) testing. Our results lend further support for tongue swabs as exceptionally easy-to-collect samples for high-throughput TB testing.


Assuntos
Mycobacterium tuberculosis , Tuberculose Pulmonar , Tuberculose , Humanos , Tuberculose Pulmonar/diagnóstico , Mycobacterium tuberculosis/genética , Sensibilidade e Especificidade , Tuberculose/diagnóstico , Tuberculose/microbiologia , África do Sul , Escarro/microbiologia
10.
J Transl Med ; 22(1): 301, 2024 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-38521955

RESUMO

BACKGROUND: Due to their complexity and to the presence of common clinical features, differentiation between asthma and chronic obstructive pulmonary disease (COPD) can be a challenging task, complicated in such cases also by asthma-COPD overlap syndrome. The distinct immune/inflammatory and structural substrates of COPD and asthma are responsible for significant differences in the responses to standard pharmacologic treatments. Therefore, an accurate diagnosis is of central relevance to assure the appropriate therapeutic intervention in order to achieve safe and effective patient care. Induced sputum (IS) accurately mirrors inflammation in the airways, providing a more direct picture of lung cell metabolism in comparison to those specimen that reflect analytes in the systemic circulation. METHODS: An integrated untargeted metabolomics and lipidomics analysis was performed in IS of asthmatic (n = 15) and COPD (n = 22) patients based on Ultra-High-Pressure Liquid Chromatography-Mass Spectrometry (UHPLC-MS) and UHPLC-tandem MS (UHPLC-MS/MS). Partial Least Squares-Discriminant Analysis (PLS-DA) was applied to resulting dataset. The analysis of main enriched metabolic pathways and the association of the preliminary metabolites/lipids pattern identified to clinical parameters of asthma/COPD differentiation were explored. Multivariate ROC analysis was performed in order to determine the discriminatory power and the reliability of the putative biomarkers for diagnosis between COPD and asthma. RESULTS: PLS-DA indicated a clear separation between COPD and asthmatic patients. Among the 15 selected candidate biomarkers based on Variable Importance in Projection scores, putrescine showed the highest score. A differential IS bio-signature of 22 metabolites and lipids was found, which showed statistically significant variations between asthma and COPD. Of these 22 compounds, 18 were decreased and 4 increased in COPD compared to asthmatic patients. The IS levels of Phosphatidylethanolamine (PE) (34:1), Phosphatidylglycerol (PG) (18:1;18:2) and spermine were significantly higher in asthmatic subjects compared to COPD. CONCLUSIONS: This is the first pilot study to analyse the IS metabolomics/lipidomics signatures relevant in discriminating asthma vs COPD. The role of polyamines, of 6-Hydroxykynurenic acid and of D-rhamnose as well as of other important players related to the alteration of glycerophospholipid, aminoacid/biotin and energy metabolism provided the construction of a diagnostic model that, if validated on a larger prospective cohort, might be used to rapidly and accurately discriminate asthma from COPD.


Assuntos
Asma , Doença Pulmonar Obstrutiva Crônica , Humanos , Lipidômica , Espectrometria de Massas em Tandem/métodos , Escarro/metabolismo , Diagnóstico Diferencial , Reprodutibilidade dos Testes , Projetos Piloto , Estudos Prospectivos , Asma/diagnóstico , Asma/metabolismo , Biomarcadores , Metabolômica/métodos , Lipídeos
11.
Respir Res ; 25(1): 223, 2024 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-38811936

RESUMO

BACKGROUND: Community-acquired pneumonia (CAP) is a common and serious condition that can be caused by a variety of pathogens. However, much remains unknown about how these pathogens interact with the lower respiratory commensals, and whether any correlation exists between the dysbiosis of the lower respiratory microbiota and disease severity and prognosis. METHODS: We conducted a retrospective cohort study to investigate the composition and dynamics of sputum microbiota in patients diagnosed with CAP. In total, 917 sputum specimens were collected consecutively from 350 CAP inpatients enrolled in six hospitals following admission. The V3-V4 region of the 16 S rRNA gene was then sequenced. RESULTS: The sputum microbiota in 71% of the samples were predominately composed of respiratory commensals. Conversely, 15% of the samples demonstrated dominance by five opportunistic pathogens. Additionally, 5% of the samples exhibited sterility, resembling the composition of negative controls. Compared to non-severe CAP patients, severe cases exhibited a more disrupted sputum microbiota, characterized by the highly dominant presence of potential pathogens, greater deviation from a healthy state, more significant alterations during hospitalization, and sparser bacterial interactions. The sputum microbiota on admission demonstrated a moderate prediction of disease severity (AUC = 0.74). Furthermore, different pathogenic infections were associated with specific microbiota alterations. Acinetobacter and Pseudomonas were more abundant in influenza A infections, with Acinetobacter was also enriched in Klebsiella pneumoniae infections. CONCLUSION: Collectively, our study demonstrated that pneumonia may not consistently correlate with severe dysbiosis of the respiratory microbiota. Instead, the degree of microbiota dysbiosis was correlated with disease severity in CAP patients.


Assuntos
Infecções Comunitárias Adquiridas , Microbiota , Índice de Gravidade de Doença , Escarro , Humanos , Infecções Comunitárias Adquiridas/microbiologia , Infecções Comunitárias Adquiridas/diagnóstico , Infecções Comunitárias Adquiridas/epidemiologia , Masculino , Feminino , Escarro/microbiologia , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos , Estudos Longitudinais , Estudos de Coortes , Disbiose/microbiologia , Disbiose/diagnóstico , Pneumonia/microbiologia , Pneumonia/diagnóstico , Pneumonia Bacteriana/microbiologia , Pneumonia Bacteriana/diagnóstico , Pneumonia Bacteriana/epidemiologia , Idoso de 80 Anos ou mais , Adulto
12.
Nitric Oxide ; 145: 57-59, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38428515

RESUMO

Emerging data from clinical studies have shown pro-inflammatory effects associated with e-cigarette use. Fractional exhaled nitric oxide (FeNO) is a biomarker of pulmonary type 2 (T2) inflammation. The effect of chronic e-cigarette use on FeNO is unclear. The aim of this study was to compare FeNO levels in COPD ex-smokers who use e-cigarettes (COPDE + e-cig) to COPDE ex-smokers (COPDE) and COPD current smokers (COPDS). FeNO levels were significantly higher in COPDE + e-cig (median 16.2 ppb) and COPDE (median 18.0 ppb) compared to COPDS (median 7.6 ppb) (p = 0.0003 and p < 0.0001 respectively). There was no difference in FeNO levels between COPDE + e-cig compared to COPDE (p > 0.9). The importance of our results is that electronic cigarette use does not alter the interpretation of FeNO results, and so does not interfere with the use of FeNO as a practical biomarker of T2 inflammation, unlike current cigarette smoking in COPD. Whilst the effect of electronic cigarette use on FeNO levels is not the same as cigarette smoke, this cannot be taken as evidence that electronic cigarettes are harmless. These differential pulmonary effects can be attributed to differences in the chemical composition of the two products.


Assuntos
Sistemas Eletrônicos de Liberação de Nicotina , Doença Pulmonar Obstrutiva Crônica , Humanos , Óxido Nítrico , Testes Respiratórios , Inflamação , Expiração , Biomarcadores
13.
Infection ; 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38589747

RESUMO

PURPOSE: Bronchoalveolar lavage is commonly used in clinical practice for unresolved pneumonia. However, bronchoalveolar lavage is not suitable for all patients as it is an invasive procedure and can worsen oxygenation. The diagnostic value of bronchial wash and sputum has been debated extensively over the years. In this study, we aim to compare the diagnostic value in several pathogens of bronchoalveolar lavage and bronchial wash, and secondarily bronchoalveolar lavage and sputum. METHODS: We retrospectively included all adult patients in our hospital who underwent bronchoalveolar lavage, bronchial wash, and where sputum sampling was done between January 1st of 2018 and December 31st of 2021. The intraclass correlation coefficient was computed for the three tests. RESULTS: In total, 308 patients were included. We found a level of correlation of 0.819 and 0.865, respectively, between bronchoalveolar lavage and bronchial wash for two pathogens: Staphylococcus aureus and Pseudomonas aeruginosa. For Stenotrophomonas maltophilia and Aspergillus fumigatus, we found an intraclass correlation coefficient of 0.568 and 0.624, respectively. Between bronchoalveolar lavage and sputum, we found varying levels of agreement. CONCLUSION: Our study shows reasonably well agreement levels between bronchoalveolar lavage and bronchial wash, suggesting that bronchial wash could potentially be an alternative to bronchoalveolar lavage.

14.
Infection ; 2024 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-38884858

RESUMO

BACKGROUND: Escalating cases of multidrug-resistant tuberculosis (MDR-TB) pose a major challenge to global TB control efforts, necessitating innovative diagnostics to empower decentralized detection of gene mutations associated with resistance to rifampicin (RIF) and isoniazid (INH) in Mycobacterium tuberculosis (M. tuberculosis) in resource-constrained settings. METHODS: Combining multiplex fluorescent PCR and Multiple Probes Melting Analysis, we identified mutations in the rpoB, katG, ahpC and inhA genes from sputum specimens. We first constructed a reference plasmid library comprising 40 prevalent mutations in the target genes' resistance determining regions and promoters, serving as positive controls. Our assay utilizes a four-tube asymmetric PCR method with specifically designed molecular beacon probes, enabling simultaneous detection of all 40 mutations. We evaluated the assay's effectiveness using DNA isolated from 50 clinically confirmed M. tuberculosis sputum specimens, comparing our results with those obtained from Sanger sequencing and retrospective validation involving bacteriological culture and phenotypic drug susceptibility testing (pDST). We also included the commercial Xpert MTB/RIF assay for accuracy comparison. RESULTS: Our data demonstrated remarkable sensitivity in detecting resistance to RIF and INH, achieving values of 93.33% and 95.24%, respectively, with a specificity of 100%. The concordance between our assay and pDST was 98.00%. Furthermore, the accuracy of our assay was comparable to both Sanger sequencing and the Xpert assay. Importantly, our assay boasts a 4.2-h turnaround time and costs only $10 per test, making it an optimal choice for peripheral healthcare settings. CONCLUSION: These findings highlight our assay's potential as a promising tool for rapidly, accurately, and affordably detecting MDR-TB.

15.
BMC Infect Dis ; 24(1): 169, 2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38326758

RESUMO

OBJECTIVE: We aimed to evaluate the sputum culture conversion time of DR-TB patients and its related factors. METHODS: PubMed, The Cochrane Library, Embase, CINAHL, Web of Science, CNKI, Wan Fang, CBM and VIP databases were electronically searched to collect studies on sputum culture conversion time in patients with DR-TB. Meta-analysis was performed by using the R 4.3.0 version and Stata 16 software. RESULTS: A total of 45 studies involving 17373 patients were included. Meta-analysis results showed that the pooled median time to sputum culture conversion was 68.57 days (IQR 61.01,76.12). The median time of sputum culture conversion in patients with drug-resistant tuberculosis was different in different WHO regions, countries with different levels of development and different treatment schemes. And female (aHR = 0.59,95%CI: s0.46,0.76), alcohol history (aHR = 0.70,95%CI:0.50,0.98), smoking history (aHR = 0.58,95%CI:0.38,0.88), history of SLD use (aHR = 0.64,95%CI:0.47,0.87), BMI < 18.5 kg/m2 (aHR = 0.69,95%CI:0.60,0.80), lung cavity (aHR = 0.70,95%CI:0.52,0.94), sputum smear grading at baseline (Positive) (aHR = 0.56,95%CI:0.36,0.87), (grade 1+) (aHR = 0.87,95%CI:0.77,0.99), (grade 2+) (aHR = 0.81,95%CI:0.69,0.95), (grade 3+) (aHR = 0.71,95%CI:0.61,0.84) were the related factor of sputum culture conversion time in patients with DR-TB. CONCLUSION: Patients with DR-TB in Europe or countries with high level of economic development have earlier sputum culture conversion, and the application of bedaquiline can make patients have shorter sputum culture conversion time. Female, alcohol history, smoking history, history of SLD use, BMI < 18.5 kg/m2, lung cavity, sputum smear grading at baseline (Positive, grade 1+, grade 2+, grade 3+) may be risk factors for longer sputum culture conversion time. This systematic review has been registered in PROSPERO, the registration number is CRD42023438746.


Assuntos
Mycobacterium tuberculosis , Tuberculose Resistente a Múltiplos Medicamentos , Tuberculose Pulmonar , Humanos , Feminino , Antituberculosos/uso terapêutico , Escarro , Tuberculose Resistente a Múltiplos Medicamentos/tratamento farmacológico , Tuberculose Pulmonar/diagnóstico , Tuberculose Pulmonar/tratamento farmacológico , Fatores de Risco , Resultado do Tratamento
16.
Environ Sci Technol ; 2024 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-38237041

RESUMO

Herein, 16 traditional and 13 novel organophosphate esters (OPEs) in skin wipes, personal PM2.5, sputum, and nails (fingernails and toenails) and 7 OPE metabolites in urine synchronously obtained from 64 college students were analyzed. Similar compositional profiles of the OPEs were found in skin wipes and nails and in personal PM2.5 and induced sputum. Significant correlations were observed between the concentrations of high-lipophilicity low-volatility OPEs in skin wipes and nails and between the concentrations of high-volatility low-lipophilicity OPEs in personal PM2.5 and sputum. These results imply that OPEs in fingernails and toenails may mainly come from external sources rather than internal exposure, and human nails and sputum can be used as indicators of human exposure to OPEs. A comparison between the daily exposure doses of the OPEs in personal PM2.5 and sputum shows that more volatile compounds may have higher inhalation bioavailability, which should be considered to improve the accuracy of inhalation exposure assessments. According to comprehensive external and internal exposure assessment, dermal absorption may be a more dominant pathway than inhalation, and skin wipes may be the best representative environmental matrix of human exposure to OPEs.

17.
BMC Infect Dis ; 24(1): 615, 2024 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-38907220

RESUMO

OBJECTIVE: To determine the relationship of Neutrophil Lymphocyte Ratio (NLR), Monocyte Lymphocyte Ratio (MLR), and Neutrophil Monocyte Ratio (NMR) with treatment response in Pulmonary Tuberculosis (PTB) patients during intensive phase treatment (IPT). METHODS: This analytical cross-sectional study was conducted at Ojha Institute of Chest Diseases (OICD), Dow University of Health Sciences, from February to December 2021. 100 patients were enrolled using purposive sampling technique. Both male and female of age 18 and above, rifampicin sensitive newly diagnosed cases of PTB by Acid Fast Bacilli (AFB) microscopy and Gene Xpert MTB/RIF were included. SPSS version 26 was used to analyze data. Numerical data was expressed in median and interquartile range and categorical data was expressed in frequencies and percentages. RESULTS: Out of total 100 patients, 81% (n = 81) showed treatment response with negative AFB Sputum Smear Microscopy (SSM) after 2nd month. Out of 81% (n = 81) of the patients who achieved treatment response, 83.9% (n = 68) also had decreased NLR, 85.2% (n = 69) had decreased MLR and 83.9% (n = 68) had decreased NMR from baseline. However 19% (n = 19) did not achieved treatment response with positive AFB SSM after 2nd month of ATT (Anti tuberculosis treatment), among them 10.52% (n = 2) were INH resistant with no decrease in all the ratios after 2nd month. CONCLUSION: Leukocyte ratios decreased significantly from baseline as PTB was treated in patients who achieved treatment response with negative AFB SSM after two months of ATT and hence these ratios could be used as markers to monitor the treatment response.


Assuntos
Antituberculosos , Linfócitos , Monócitos , Neutrófilos , Tuberculose Pulmonar , Humanos , Masculino , Feminino , Tuberculose Pulmonar/tratamento farmacológico , Tuberculose Pulmonar/sangue , Tuberculose Pulmonar/microbiologia , Adulto , Estudos Transversais , Pessoa de Meia-Idade , Antituberculosos/uso terapêutico , Resultado do Tratamento , Adulto Jovem , Escarro/microbiologia , Adolescente , Rifampina/uso terapêutico
18.
J Asthma ; 61(7): 671-676, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38145333

RESUMO

BACKGROUND: Tailoring asthma interventions based on biomarkers could substantially impact the high cost associated with asthma morbidity. For policymakers, the main concern is the economic impact of adopting this technology, especially in developing countries. This study evaluates the budget impact of asthma management using sputum eosinophil counts in Colombia patients between 4 and 18 years of age. METHODS: A budget impact analysis was performed to evaluate the potential financial impact of sputum eosinophil counts (EO). The study considered a 5-year time horizon and the Colombian National Health System perspective. The incremental budget impact was calculated by subtracting the cost of the new treatment, in which EO is reimbursed, from the cost of the conventional therapy without EO (management based on clinical symptoms (with or without spirometry/peak flow) or asthma guidelines (or both), for asthma-related). Univariate one-way sensitivity analyses were performed. RESULTS: In the base-case analysis, the 5-year costs associated with EO and no-EO were estimated to be US$ 532.865.915 and US$ 540.765.560, respectively, indicating savings for Colombian National Health equal to US$ 7.899.645, if EO is adopted for the routine management of patients with persistent asthma. This result was robust in univariate sensitivity one-way analysis. CONCLUSION: EO was cost-saving in guiding the treatment of patients between 4 and 18 years of age with persistent asthma. Decision-makers in our country can use this evidence to improve clinical practice guidelines, and it should be replicated to validate their results in other middle-income countries.


Assuntos
Asma , Eosinófilos , Guias de Prática Clínica como Assunto , Escarro , Humanos , Asma/economia , Asma/terapia , Criança , Adolescente , Colômbia , Pré-Escolar , Escarro/citologia , Contagem de Leucócitos , Feminino , Masculino , Redução de Custos/estatística & dados numéricos , Países em Desenvolvimento
19.
Respirology ; 29(5): 372-378, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38556839

RESUMO

Sputum induction is widely used in clinical settings for collection of biological samples from the lower airways. However, in recent years sputum induction has been associated with serious adverse events and even death. This position statement was commissioned by the Thoracic Society of Australia and New Zealand to address major adverse events of two deaths associated with sputum induction that have occurred in Australia in 2021, and outlines best practice for the safe use of sputum induction. The statement resulted from systematic literature searches by a multi-disciplinary group including respiratory physicians, nurses and physiotherapists (paediatric and adults focused). Consumers had input to an advanced draft of the position statement. The position statement covers indications for sputum induction, informed consent, scope of practice of personnel administering the procedure, infection control considerations, details about the sputum induction procedure, safety considerations and risk assessment in clinical settings.


Assuntos
Escarro , Adulto , Humanos , Criança , Solução Salina Hipertônica , Nova Zelândia , Austrália , Volume Expiratório Forçado
20.
J Infect Chemother ; 30(8): 780-784, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38182008

RESUMO

Patients with Mycobacterium avium complex pulmonary disease (MAC-PD) often suffer from chronic symptoms such as sputum production, which reduces quality of life. Oscillatory positive expiratory pressure (OPEP) devices are used in physiotherapy to promote the clearance of respiratory secretions. We report two cases of improved lung function and improved scores on the Leicester Cough Questionnaire (LCQ) and the Breathlessness, Cough and Sputum Scale (BCSS) after the use of OPEP in patients with MAC-PD where treatment with guideline-based therapy, including amikacin liposome inhalation suspension, had proved ineffective for symptoms. Use of OPEP might maximize the efficacy of therapy and thereby improves outcomes in patients with MAC-PD. It is important to use both guideline-based therapy and OPEP, especially in patients whose health-related quality of life is affected by sputum symptoms. Further prospective studies are warranted to assess the benefit of adding OPEP to guidelines concerning therapy for patients with MAC-PD and sputum symptoms.


Assuntos
Complexo Mycobacterium avium , Infecção por Mycobacterium avium-intracellulare , Qualidade de Vida , Humanos , Infecção por Mycobacterium avium-intracellulare/terapia , Infecção por Mycobacterium avium-intracellulare/microbiologia , Masculino , Idoso , Escarro/microbiologia , Feminino , Respiração com Pressão Positiva/instrumentação , Respiração com Pressão Positiva/métodos , Pessoa de Meia-Idade , Antibacterianos/uso terapêutico , Antibacterianos/administração & dosagem , Resultado do Tratamento , Pneumopatias/microbiologia , Pneumopatias/terapia , Pneumopatias/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA