Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20.823
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Cell ; 154(3): 481-3, 2013 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-23911315

RESUMO

The selective breeding of rats as physiological, behavioral, and disease models generated a wealth of variation relevant to the genetics of complex traits. In this issue, Atanur and colleagues sequence the genomes of 25 inbred rat strains to understand how artificial selection shaped their genomes.


Assuntos
Eletrocardiografia/métodos , Cuidados Intraoperatórios/métodos , Humanos
2.
Circ Res ; 132(1): 127-149, 2023 01 06.
Artigo em Inglês | MEDLINE | ID: mdl-36603066

RESUMO

Cardiac alternans arises from dynamical instabilities in the electrical and calcium cycling systems of the heart, and often precedes ventricular arrhythmias and sudden cardiac death. In this review, we integrate clinical observations with theory and experiment to paint a holistic portrait of cardiac alternans: the underlying mechanisms, arrhythmic manifestations and electrocardiographic signatures. We first summarize the cellular and tissue mechanisms of alternans that have been demonstrated both theoretically and experimentally, including 3 voltage-driven and 2 calcium-driven alternans mechanisms. Based on experimental and simulation results, we describe their relevance to mechanisms of arrhythmogenesis under different disease conditions, and their link to electrocardiographic characteristics of alternans observed in patients. Our major conclusion is that alternans is not only a predictor, but also a causal mechanism of potentially lethal ventricular and atrial arrhythmias across the full spectrum of arrhythmia mechanisms that culminate in functional reentry, although less important for anatomic reentry and focal arrhythmias.


Assuntos
Cálcio , Coração , Humanos , Arritmias Cardíacas , Morte Súbita Cardíaca/etiologia , Eletrocardiografia/métodos
3.
Eur Heart J ; 45(14): 1255-1265, 2024 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-38445836

RESUMO

BACKGROUND AND AIMS: Available data on continuous rhythm monitoring by implantable loop recorders (ILRs) in patients with Brugada syndrome (BrS) are scarce. The aim of this multi-centre study was to evaluate the diagnostic yield and clinical implication of a continuous rhythm monitoring strategy by ILRs in a large cohort of BrS patients and to assess the precise arrhythmic cause of syncopal episodes. METHODS: A total of 370 patients with BrS and ILRs (mean age 43.5 ± 15.9, 33.8% female, 74.1% symptomatic) from 18 international centers were included. Patients were followed with continuous rhythm monitoring for a median follow-up of 3 years. RESULTS: During follow-up, an arrhythmic event was recorded in 30.7% of symptomatic patients [18.6% atrial arrhythmias (AAs), 10.2% bradyarrhythmias (BAs), and 7.3% ventricular arrhythmias (VAs)]. In patients with recurrent syncope, the aetiology was arrhythmic in 22.4% (59.3% BAs, 25.0% VAs, and 15.6% AAs). The ILR led to drug therapy initiation in 11.4%, ablation procedure in 10.9%, implantation of a pacemaker in 2.5%, and a cardioverter-defibrillator in 8%. At multivariate analysis, the presence of symptoms [hazard ratio (HR) 2.5, P = .001] and age >50 years (HR 1.7, P = .016) were independent predictors of arrhythmic events, while inducibility of ventricular fibrillation at the electrophysiological study (HR 9.0, P < .001) was a predictor of VAs. CONCLUSIONS: ILR detects arrhythmic events in nearly 30% of symptomatic BrS patients, leading to appropriate therapy in 70% of them. The most commonly detected arrhythmias are AAs and BAs, while VAs are detected only in 7% of cases. Symptom status can be used to guide ILR implantation.


Assuntos
Síndrome de Brugada , Desfibriladores Implantáveis , Marca-Passo Artificial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Arritmias Cardíacas/complicações , Arritmias Cardíacas/diagnóstico , Síndrome de Brugada/complicações , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/terapia , Eletrocardiografia/métodos , Eletrocardiografia Ambulatorial/métodos , Adulto
4.
Diabetologia ; 67(4): 641-649, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38267653

RESUMO

AIMS/HYPOTHESIS: Type 2 diabetes is associated with a high risk of sudden cardiac death (SCD), but the risk of dying from another cause (non-SCD) is proportionally even higher. The aim of the study was to identify easily available ECG-derived features associated with SCD, while considering the competing risk of dying from non-SCD causes. METHODS: In the SURDIAGENE (Survie, Diabete de type 2 et Genetique) French prospective cohort of individuals with type 2 diabetes, 15 baseline ECG parameters were interpreted among 1362 participants (mean age 65 years; HbA1c 62±17 mmol/mol [7.8±1.5%]; 58% male). Competing risk models assessed the prognostic value of clinical and ECG parameters for SCD after adjusting for age, sex, history of myocardial infarction, N-terminal pro b-type natriuretic peptide (NT-proBNP), HbA1c and eGFR. The prospective Mini-Finland cohort study was used to externally validate our findings. RESULTS: During median follow-up of 7.4 years, 494 deaths occurred including 94 SCDs. After adjustment, frontal QRS-T angle ≥90° (sub-distribution HR [sHR] 1.68 [95% CI 1.04, 2.69], p=0.032) and NT-proBNP level (sHR 1.26 [95% CI 1.06, 1.50] per 1 log, p=0.009) were significantly associated with a higher risk of SCD. Nevertheless, frontal QRS-T angle was the only marker not to be associated with causes of death other than SCD (sHR 1.08 [95% CI 0.84, 1.39], p=0.553 ). These findings were replicated in the Mini-Finland study subset of participants with diabetes (sHR 2.22 [95% CI 1.05, 4.71], p=0.04 for SCD and no association for other causes of death). CONCLUSIONS/INTERPRETATION: QRS-T angle was specifically associated with SCD risk and not with other causes of death, opening an avenue for refining SCD risk stratification in individuals with type 2 diabetes.


Assuntos
Diabetes Mellitus Tipo 2 , Humanos , Masculino , Idoso , Feminino , Estudos de Coortes , Estudos Prospectivos , Diabetes Mellitus Tipo 2/complicações , Finlândia , Medição de Risco , Eletrocardiografia/efeitos adversos , Eletrocardiografia/métodos , Morte Súbita Cardíaca/etiologia , Fatores de Risco
5.
Circulation ; 147(21): 1568-1578, 2023 05 23.
Artigo em Inglês | MEDLINE | ID: mdl-36960730

RESUMO

BACKGROUND: Treatment options for high-risk Brugada syndrome (BrS) with recurrent ventricular fibrillation (VF) are limited. Catheter ablation is increasingly performed but a large study with long-term outcome data is lacking. We report the results of the multicenter, international BRAVO (Brugada Ablation of VF Substrate Ongoing Registry) for treatment of high-risk symptomatic BrS. METHODS: We enrolled 159 patients (median age 42 years; 156 male) with BrS and spontaneous VF in BRAVO; 43 (27%) of them had BrS and early repolarization pattern. All but 5 had an implantable cardioverter-defibrillator for cardiac arrest (n=125) or syncope (n=34). A total of 140 (88%) had experienced numerous implantable cardioverter-defibrillator shocks for spontaneous VF before ablation. All patients underwent a percutaneous epicardial substrate ablation with electroanatomical mapping except for 8 who underwent open-thoracotomy ablation. RESULTS: In all patients, VF/BrS substrates were recorded in the epicardial surface of the right ventricular outflow tract; 45 (29%) patients also had an arrhythmic substrate in the inferior right ventricular epicardium and 3 in the posterior left ventricular epicardium. After a single ablation procedure, 128 of 159 (81%) patients remained free of VF recurrence; this number increased to 153 (96%) after a repeated procedure (mean 1.2±0.5 procedures; median=1), with a mean follow-up period of 48±29 months from the last ablation. VF burden and frequency of shocks decreased significantly from 1.1±2.1 per month before ablation to 0.003±0.14 per month after the last ablation (P<0.0001). The Kaplan-Meier VF-free survival beyond 5 years after the last ablation was 95%. The only variable associated with a VF-free outcome in multivariable analysis was normalization of the type 1 Brugada ECG, both with and without sodium-channel blockade, after the ablation (hazard ratio, 0.078 [95% CI, 0.008 to 0.753]; P=0.0274). There were no arrhythmic or cardiac deaths. Complications included hemopericardium in 4 (2.5%) patients. CONCLUSIONS: Ablation treatment is safe and highly effective in preventing VF recurrence in high-risk BrS. Prospective studies are needed to determine whether it can be an alternative treatment to implantable cardioverter-defibrillator implantation for selected patients with BrS. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT04420078.


Assuntos
Síndrome de Brugada , Ablação por Cateter , Desfibriladores Implantáveis , Humanos , Masculino , Adulto , Fibrilação Ventricular , Eletrocardiografia/métodos , Ventrículos do Coração , Síndrome de Brugada/cirurgia , Síndrome de Brugada/complicações , Desfibriladores Implantáveis/efeitos adversos , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Sistema de Registros
6.
Pflugers Arch ; 476(8): 1187-1207, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38937370

RESUMO

Autonomic control of heart rate is well known in adult subjects, but limited data are available on the development of the heart rate control during childhood and adolescence. Continuous 12-lead electrocardiograms were recorded in 1045 healthy children and adolescents (550 females) aged 4 to 19 years during postural manoeuvres involving repeated 10-min supine, unsupported sitting, and unsupported standing positions. In each position, heart rate was measured, and heart rate variability indices were evaluated (SDNN, RMSSD, and high (HF) and low (LF) frequency components were obtained). Quasi-normalized HF frequency components were defined as qnHF = HF/(HF + LF). These measurements were, among others, related to age using linear regressions. In supine position, heart rate decreases per year of age were significant in both sexes but lower in females than in males. In standing position, these decreases per year of age were substantially lowered. RMSSD and qnHF indices were independent of age in supine position but significantly decreased with age in sitting and standing positions. Correspondingly, LF/HF proportions showed steep increases with age in sitting and standing positions but not in the supine position. The study suggests that baseline supine parasympathetic influence shows little developmental changes during childhood and adolescence but that in young children, sympathetic branch is less responsive to vagal influence. While vagal influences modulate cardiac periods in young and older children equally, they are less able to suppress the sympathetic influence in younger children.


Assuntos
Sistema Nervoso Autônomo , Frequência Cardíaca , Humanos , Frequência Cardíaca/fisiologia , Adolescente , Feminino , Masculino , Criança , Pré-Escolar , Sistema Nervoso Autônomo/fisiologia , Adulto Jovem , Decúbito Dorsal , Eletrocardiografia/métodos , Postura/fisiologia , Adulto
7.
Pflugers Arch ; 476(7): 1145-1154, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38703193

RESUMO

Arrhythmia detection is essential when assessing the safety of novel drugs and therapies in preclinical studies. Many short-term arrhythmia monitoring methods exist, including non-invasive ECG and Holter. However, there are no reliable, long-term, non-invasive, or minimally invasive methods for cardiac arrhythmia follow-up in large animals that allows free movement with littermates. A long follow-up time is needed when estimating the impact of long-lasting drugs or therapies, such as gene therapy. We evaluated the feasibility and performance of insertable cardiac monitors (ICMs) in pigs for minimally invasive, long-term monitoring of cardiac arrhythmias that allows free movement and species-specific behavior. Multiple implantation sites were tested to assess signal quality. ICMs recognized reliably many different arrhythmias but failed to detect single extrasystoles. They also over-diagnosed T-waves, resulting in oversensing. Muscle activity and natural startles of the animals caused noise, leading to a heterogeneous signal requiring post-recording evaluation. In spite of these shortcomings, the ICMs showed to be very useful for minimally invasive long-term monitoring of cardiac rhythm in pigs.


Assuntos
Arritmias Cardíacas , Animais , Suínos , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Eletrocardiografia Ambulatorial/instrumentação , Eletrocardiografia Ambulatorial/métodos , Eletrocardiografia/métodos , Eletrocardiografia/instrumentação , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Monitorização Fisiológica/veterinária
8.
Eur J Neurosci ; 60(3): 4201-4216, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38797841

RESUMO

Unconsciousness in severe acquired brain injury (sABI) patients occurs with different cognitive and neural profiles. Perturbational approaches, which enable the estimation of proxies for brain reorganization, have added a new avenue for investigating the non-behavioural diagnosis of consciousness. In this prospective observational study, we conducted a comparative analysis of the topological patterns of heartbeat-evoked potentials (HEP) between patients experiencing a prolonged disorder of consciousness (pDoC) and patients emerging from a minimally consciousness state (eMCS). A total of 219 sABI patients were enrolled, each undergoing a synchronous EEG-ECG resting-state recording, together with a standardized consciousness diagnosis. A number of graph metrics were computed before/after the HEP (Before/After) using the R-peak on the ECG signal. The peak value of the global field power of the HEP was found to be significantly higher in eMCS patients with no difference in latency. Power spectrum was not able to discriminate consciousness neither Before nor After. Node assortativity and global efficiency were found to vary with different trends at unconsciousness. Lastly, the Perturbational Complexity Index of the HEP was found to be significantly higher in eMCS patients compared with pDoC. Given that cortical elaboration of peripheral inputs may serve as a non-behavioural determinant of consciousness, we have devised a low-cost and translatable technique capable of estimating causal proxies of brain functionality with an endogenous, non-invasive stimulus. Thus, we present an effective means to enhance consciousness assessment by incorporating the interaction between the autonomic nervous system (ANS) and central nervous system (CNS) into the loop.


Assuntos
Lesões Encefálicas , Eletroencefalografia , Potenciais Evocados , Frequência Cardíaca , Inconsciência , Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Frequência Cardíaca/fisiologia , Eletroencefalografia/métodos , Inconsciência/fisiopatologia , Lesões Encefálicas/fisiopatologia , Lesões Encefálicas/diagnóstico , Potenciais Evocados/fisiologia , Eletrocardiografia/métodos , Estudos Prospectivos , Idoso , Estado Vegetativo Persistente/fisiopatologia , Estado Vegetativo Persistente/diagnóstico , Adulto Jovem
9.
Eur Respir J ; 64(1)2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38936966

RESUMO

BACKGROUND: Early diagnosis of pulmonary hypertension (PH) is critical for effective treatment and management. We aimed to develop and externally validate an artificial intelligence algorithm that could serve as a PH screening tool, based on analysis of a standard 12-lead ECG. METHODS: The PH Early Detection Algorithm (PH-EDA) is a convolutional neural network developed using retrospective ECG voltage-time data, with patients classified as "PH-likely" or "PH-unlikely" (controls) based on right heart catheterisation or echocardiography. In total, 39 823 PH-likely patients and 219 404 control patients from Mayo Clinic were randomly split into training (48%), validation (12%) and test (40%) sets. ECGs taken within 1 month of PH diagnosis (diagnostic dataset) were used to train the PH-EDA at Mayo Clinic. Performance was tested on diagnostic ECGs within the test sets from Mayo Clinic (n=16 175/87 998 PH-likely/controls) and Vanderbilt University Medical Center (VUMC; n=6045/24 256 PH-likely/controls). In addition, performance was tested on ECGs taken 6-18 months (pre-emptive dataset), and up to 5 years prior to a PH diagnosis at both sites. RESULTS: Performance testing yielded an area under the receiver operating characteristic curve (AUC) of 0.92 and 0.88 in the diagnostic test sets at Mayo Clinic and VUMC, respectively, and 0.86 and 0.81, respectively, in the pre-emptive test sets. The AUC remained a minimum of 0.79 at Mayo Clinic and 0.73 at VUMC up to 5 years before diagnosis. CONCLUSION: The PH-EDA can detect PH at diagnosis and 6-18 months prior, demonstrating the potential to accelerate diagnosis and management of this debilitating disease.


Assuntos
Algoritmos , Diagnóstico Precoce , Eletrocardiografia , Hipertensão Pulmonar , Humanos , Hipertensão Pulmonar/diagnóstico , Eletrocardiografia/métodos , Feminino , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Idoso , Inteligência Artificial , Curva ROC , Ecocardiografia , Adulto , Redes Neurais de Computação , Cateterismo Cardíaco
10.
Am Heart J ; 270: 117-124, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38342392

RESUMO

INTRODUCTION: Low QRS peak-to-nadir voltage (LQRSV) is associated with arrhythmogenic right ventricular cardiomyopathy (ARVC) and other cardiomyopathies. Recent studies have proposed criteria for LQRSV when screening athletes for cardiovascular disease. These criteria have not yet been evaluated in a large population of healthy young athletes. METHODS: The target population was 10,728 (42.5% female, 57.5% male, mean age 18.1 ± 4.3 years) athletes who participated in mass ECG screenings between 2014 and 2021 at multiple sites across the United States including grade schools (11%), high schools (32%), colleges (50%), and professional athletic teams (6%) with digitally recorded ECGs and a standardized protocol. Since by design, complete follow up for outcomes and the results of testing were not available. Including only ECGs from initial evaluation among athletes 14-35 years of age and excluding those with right bundle branch block, left bundle branch block, Wolf-Parkinson-White pattern, reversed leads and 3 clinically diagnosed cardiomyopathies at Stanford, 8,679 (58% males, 42% females) remained eligible for analysis. QRS voltage was analyzed for each ECG lead and LQRSV criteria were applied and stratified by sex. RESULTS: QRS voltage was lower in all leads in female athletes compared to male athletes. Using traditional limb lead criteria or precordial lead criteria, the prevalence of LQRSV was significantly lower in males than females (P < .001). Strikingly, LQRSV using the Sokolow-Lyon Index was present in 1.9% of males and 9.8% of females (P < .001). Applying first percentile for LQRS amplitude criteria provided possible values for screening young athletes for LQRSV. CONCLUSIONS: LQRSV is more common among female athletes than male athletes using established criteria. Using first percentile sex-specific cut points should be considered in future analyses. Proposed novel LQRSV criteria in young athletes should be specific for males and females.


Assuntos
Displasia Arritmogênica Ventricular Direita , Cardiomiopatias , Humanos , Masculino , Feminino , Adolescente , Adulto Jovem , Adulto , Eletrocardiografia/métodos , Cardiomiopatias/diagnóstico , Programas de Rastreamento , Bloqueio de Ramo
11.
Am Heart J ; 271: 164-177, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38395294

RESUMO

BACKGROUND: Atrial fibrillation (AF) increases the risk of death, stroke, heart failure, cognitive decline, and healthcare costs but is often asymptomatic and undiagnosed. There is currently no national screening program for AF. The advent of validated hand-held devices allows AF to be detected in non-healthcare settings, enabling screening to be undertaken within the community. METHOD AND RESULTS: In this novel observational study, we embedded a MyDiagnostick single lead ECG sensor into the handles of shopping trolleys in four supermarkets in the Northwest of England: 2155 participants were recruited. Of these, 231 participants either activated the sensor or had an irregular pulse, suggesting AF. Some participants agreed to use the sensor but refused to provide their contact details, or consent to pulse assessment. In addition, some data were missing, resulting in 203 participants being included in the final analyses. Fifty-nine participants (mean age 73.6 years, 43% female) were confirmed or suspected of having AF; 20 were known to have AF and 39 were previously undiagnosed. There was no evidence of AF in 115 participants and the remaining 46 recordings were non-diagnostic, mainly due to artefact. Men and older participants were significantly more likely to have newly diagnosed AF. Due to the number of non-diagnostic ECGs (n = 46), we completed three levels of analyses, excluding all non-diagnostic ECGs, assuming all non-diagnostic ECGs were masking AF, and assuming all non-diagnostic ECGs were not AF. Based on the results of the three analyses, the sensor's sensitivity (95% CI) ranged from 0.70 to 0.93; specificity from 0.15 to 0.97; positive predictive values (PPV) and negative predictive values (NPV) ranged from 0.24 to 0.56 and 0.55 to 1.00, respectively. These values should be interpreted with caution, as the ideal reference standard on 1934 participants was imperfect. CONCLUSION: The study demonstrates that the public will engage with AF screening undertaken as part of their daily routines using hand-held devices. Sensors can play a key role in identifying asymptomatic patients in this way, but the technology must be further developed to reduce the quantity of non-diagnostic ECGs.


Assuntos
Fibrilação Atrial , Eletrocardiografia , Estudos de Viabilidade , Programas de Rastreamento , Humanos , Fibrilação Atrial/diagnóstico , Masculino , Feminino , Idoso , Eletrocardiografia/instrumentação , Eletrocardiografia/métodos , Programas de Rastreamento/métodos , Programas de Rastreamento/instrumentação , Inglaterra , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais
12.
J Cardiovasc Electrophysiol ; 35(1): 120-129, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37962088

RESUMO

INTRODUCTION: Implant procedure features and clinical implications of left bundle branch pacing (LBBP) and left ventricular septal pacing (LVSP) have not been yet fully described. We sought to compare two different left bundle branch area pacing (LBBAP) implant strategies: the first one accepting LVSP as a procedural endpoint and the second one aiming at achieving LBBP in every patient in spite of evidence of previous LVSP criteria. METHODS: LVSP was accepted as a procedural endpoint in 162 consecutive patients (LVSP strategy group). In a second phase, LBBP was attempted in every patient in spite of achieving previous LVSP criteria (n = 161, LBBP strategy group). Baseline patient characteristics, implant procedure, and follow-up data were compared. RESULTS: The final capture pattern was LBBP in 71.4% and LVSP in 24.2% in the LBBP strategy group compared to 42.7% and 50%, respectively, in the LVSP strategy group. One hundred and eighty-four patients (57%) had proven LBB capture criteria with a significantly shorter paced QRS duration than the 120 patients (37%) with LVSP criteria (115 ± 9 vs. 121 ± 13 ms, p < .001). Implant parameters were comparable between the two strategies but the LBBP strategy resulted in a higher rate of acute septal perforation (11.8% vs. 4.9%, p = .026) without any clinical sequelae. Patients with CRT indications significantly improved left ventricular ejection fraction (LVEF) during follow-up irrespective of the capture pattern (from 35 ± 11% to 45 ± 14% in proven LBBP, p = .024; and from 39 ± 13% to 47 ± 12% for LVSP, p = .003). The presence of structural heart disease and baseline LBBB independently predicted unsuccessful LBB capture. CONCLUSION: The LBBP strategy was associated with comparable implant parameters than the LVSP strategy but resulted in higher rates of septal perforation. Proven LBB capture and LVSP showed comparable effects on LVEF during follow-up.


Assuntos
Fascículo Atrioventricular , Bloqueio de Ramo , Humanos , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/terapia , Estimulação Cardíaca Artificial/métodos , Volume Sistólico , Eletrocardiografia/métodos , Função Ventricular Esquerda
13.
J Cardiovasc Electrophysiol ; 35(4): 708-714, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38348526

RESUMO

BACKGROUND: Brugada syndrome (BrS) is characterized by ST-segment elevation in the right precordial leads, which is not explained by ischemia, electrolyte disturbances, or obvious structural heart disease. AIM: In present study, we aim to evaluate presentation, long-term outcome, genetic findings, and therapeutic interventions in patients with BrS. METHODS: Between September 2001 and June 2022, all consecutive patients with diagnosis of BrS were enrolled in the present study. All patients gave written informed consent for the procedure, and the local ethical committee approved the study. RESULTS: Of the 76 cases, 79% were proband and 21% were detected during screening after diagnosis of BrS in a family member. Thirty-three (43%) patients had a typical spontaneous electrocardiogram (ECG) pattern. Thirty percent of the patients were symptomatic; symptomatic patients were more likely to have spontaneous type 1 Brugada ECG pattern in their ECGs (p = .01), longer PR interval (p = .03), and SCN5A mutation (p = .01) than asymptomatic patients. The mean PR interval was considerably longer in men than women (p = .034). SCN5A mutation was found in 9 out of 50 (18%) studied patients. Fifteen percent received appropriate implantable cardioverter-defibrillator (ICD) therapy and inappropriate ICD interventions were observed in 17%. Presentation with aborted SCD or arrhythmic syncope was the only predictor of adverse outcome in follow-up (odds ratio: 3.1, 95% confidence interval: 0.7-19.6, p = .001). CONCLUSIONS: Symptomatic patients with BrS are more likely to present with spontaneous type 1 Brugada ECG pattern, longer PR interval, and pathogenic mutation in SCN5A gene. Appropriate ICD interventions are more likely in symptomatic patients and those with SCN5A mutation.


Assuntos
Síndrome de Brugada , Desfibriladores Implantáveis , Masculino , Humanos , Feminino , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/genética , Síndrome de Brugada/terapia , Estudos Longitudinais , Irã (Geográfico) , Eletrocardiografia/métodos
14.
J Cardiovasc Electrophysiol ; 35(4): 802-810, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38409896

RESUMO

INTRODUCTION: The Mt. FUJI multicenter trial demonstrated that a delivery catheter system had a higher rate of successful right ventricular (RV) lead deployment on the RV septum (RVS) than a conventional stylet system. In this subanalysis of the Mt. FUJI trial, we assessed the differences in electrocardiogram (ECG) parameters during RV pacing between a delivery catheter system and a stylet system and their associations with the lead tip positions. METHODS: Among 70 patients enrolled in the Mt FUJI trial, ECG parameters, RV lead tip positions, and lead depth inside the septum assessed by computed tomography were compared between the catheter group (n = 36) and stylet group (n = 34). RESULTS: The paced QRS duration (QRS-d), corrected paced QT (QTc), and JT interval (JTc) were significantly shorter in the catheter group than in the stylet group (QRS-d: 130 ± 19 vs. 142 ± 15 ms, p = .004; QTc: 476 ± 25 vs. 514 ± 20 ms, p < .001; JTc: 347 ± 24 vs. 372 ± 17 ms, p < .001). This superiority of the catheter group was maintained in a subgroup analysis of patients with an RV lead tip position at the septum. The lead depth inside the septum was greater in the catheter group than in the stylet group, and there was a significant negative correlation between the paced QRS-d and the lead depth. CONCLUSION: Using a delivery catheter system carries more physiological depolarization and repolarization during RVS pacing and deeper screw penetration in the septum in comparison to conventional stylet system. The lead depth could have a more impact on the ECG parameters rather than the type of pacing lead.


Assuntos
Estimulação Cardíaca Artificial , Septo Interventricular , Humanos , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Catéteres , Eletrocardiografia/métodos , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Septo Interventricular/diagnóstico por imagem
15.
J Cardiovasc Electrophysiol ; 35(4): 701-707, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38329163

RESUMO

INTRODUCTION: Most patients with Brugada syndrome (BrS) are first diagnosed in their 40s, with sudden cardiac death (SCD) often occurring in their 50s. Ventricular fibrillation (VF) may occur in some patients with BrS despite having been asymptomatic for a long period. This study aimed to assess the incidence and risk factors for late life-threatening arrhythmias in patients with BrS. METHODS: Patients with BrS (n = 523; mean age, 51 ± 13 years; male, n = 497) were enrolled. The risk of late life-threatening arrhythmia was investigated in 225 patients who had experienced no cardiac events (CEs: SCD or ventricular tachyarrhythmia) for at least 10 years after study enrollment. The incidence of CEs during the follow-up period was examined. RESULTS: During the follow-up of the 523 patients, 59 (11%) experienced CEs. The annual incidences of CEs were 2.87%, 0.77%, and 0.09% from study enrollment to 3, 3-10, and after 10 years, respectively. Among 225 patients who had experienced no CEs for at least 10 years after enrollment, four patients (1.8%) subsequently experienced CEs. Kaplan-Meier analysis revealed significant differences in the incidence of late CEs between patients with and without a history of symptoms (p = .032). The positive and negative predictive values of late CEs for the programmed electrical stimulation (PES) test were 2.9% and 100%, respectively. CONCLUSION: Our results suggest that patients with BrS who are asymptomatic and have no ventricular tachycardia/VF inducibility by PES are at extremely low risk of experiencing late life-threatening arrhythmias.


Assuntos
Síndrome de Brugada , Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/terapia , Síndrome de Brugada/complicações , Seguimentos , Japão/epidemiologia , Eletrocardiografia/métodos , Arritmias Cardíacas/complicações , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/epidemiologia , Fibrilação Ventricular/terapia , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia
16.
Heart Fail Rev ; 29(1): 45-63, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37776404

RESUMO

Conduction system pacing is an alternative practice to conventional right ventricular apical pacing. It is a method that maintains physiologic ventricular activation, based on a correct pathophysiological basis, in which the pacing lead bypasses the lesion of the electrical fibers and the electrical impulse transmits through the intact adjacent conduction system. For this reason, it might be reasonably characterized by the term "electrical bypass" compared to the coronary artery bypass in revascularization therapy. In this review, reference is made to the sequence of events in which conventional right ventricular pacing may cause adverse outcomes. Furthermore, there is a reference to alternative strategies and pacing sites. Interest focuses on the modalities for which there are data from the literature, namely for the right ventricular (RV) septal pacing, the His bundle pacing (HBP), and the left bundle branch pacing (LBBP). A more extensive reference is about the HBP, for which there are the most updated data. We analyze the considerations that limit HBP-wide application in three axes, and we also present the data for the implantation and follow-up of these patients. The indications with their most important studies to date are then described in detail, not only in their undoubtedly positive findings but also in their weak aspects, because of which this pacing mode has not yet received a strong recommendation for implementation. Finally, there is a report on LBBP, focusing mainly on its points of differentiation from HBP.


Assuntos
Fascículo Atrioventricular , Estimulação Cardíaca Artificial , Humanos , Estimulação Cardíaca Artificial/métodos , Eletrocardiografia/métodos , Sistema de Condução Cardíaco , Ventrículos do Coração/cirurgia , Resultado do Tratamento
17.
Epilepsia ; 65(8): 2280-2294, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38780375

RESUMO

OBJECTIVE: This study was undertaken to develop and evaluate a machine learning-based algorithm for the detection of focal to bilateral tonic-clonic seizures (FBTCS) using a novel multimodal connected shirt. METHODS: We prospectively recruited patients with epilepsy admitted to our epilepsy monitoring unit and asked them to wear the connected shirt while under simultaneous video-electroencephalographic monitoring. Electrocardiographic (ECG) and accelerometric (ACC) signals recorded with the connected shirt were used for the development of the seizure detection algorithm. First, we used a sliding window to extract linear and nonlinear features from both ECG and ACC signals. Then, we trained an extreme gradient boosting algorithm (XGBoost) to detect FBTCS according to seizure onset and offset annotated by three board-certified epileptologists. Finally, we applied a postprocessing step to regularize the classification output. A patientwise nested cross-validation was implemented to evaluate the performances in terms of sensitivity, false alarm rate (FAR), time in false warning (TiW), detection latency, and receiver operating characteristic area under the curve (ROC-AUC). RESULTS: We recorded 66 FBTCS from 42 patients who wore the connected shirt for a total of 8067 continuous hours. The XGBoost algorithm reached a sensitivity of 84.8% (56/66 seizures), with a median FAR of .55/24 h and a median TiW of 10 s/alarm. ROC-AUC was .90 (95% confidence interval = .88-.91). Median detection latency from the time of progression to the bilateral tonic-clonic phase was 25.5 s. SIGNIFICANCE: The novel connected shirt allowed accurate detection of FBTCS with a low false alarm rate in a hospital setting. Prospective studies in a residential setting with a real-time and online seizure detection algorithm are required to validate the performance and usability of this device.


Assuntos
Algoritmos , Eletroencefalografia , Convulsões , Dispositivos Eletrônicos Vestíveis , Humanos , Masculino , Feminino , Adulto , Eletroencefalografia/métodos , Convulsões/diagnóstico , Convulsões/fisiopatologia , Pessoa de Meia-Idade , Adulto Jovem , Eletrocardiografia/métodos , Estudos Prospectivos , Adolescente , Aprendizado de Máquina , Acelerometria/métodos , Acelerometria/instrumentação , Epilepsia Tônico-Clônica/diagnóstico , Epilepsia Tônico-Clônica/fisiopatologia
18.
Diabetes Obes Metab ; 26(7): 2624-2633, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38603589

RESUMO

AIM: To develop and employ machine learning (ML) algorithms to analyse electrocardiograms (ECGs) for the diagnosis of cardiac autonomic neuropathy (CAN). MATERIALS AND METHODS: We used motif and discord extraction techniques, alongside long short-term memory networks, to analyse 12-lead, 10-s ECG tracings to detect CAN in patients with diabetes. The performance of these methods with the support vector machine classification model was evaluated using 10-fold cross validation with the following metrics: accuracy, precision, recall, F1 score, and area under the receiver-operating characteristic curve (AUC). RESULTS: Among 205 patients (mean age 54 ± 17 years, 54% female), 100 were diagnosed with CAN, including 38 with definite or severe CAN (dsCAN) and 62 with early CAN (eCAN). The best model performance for dsCAN classification was achieved using both motifs and discords, with an accuracy of 0.92, an F1 score of 0.92, a recall at 0.94, a precision of 0.91, and an excellent AUC of 0.93 (95% confidence interval [CI] 0.91-0.94). For the detection of any stage of CAN, the approach combining motifs and discords yielded the best results, with an accuracy of 0.65, F1 score of 0.68, a recall of 0.75, a precision of 0.68, and an AUC of 0.68 (95% CI 0.54-0.81). CONCLUSION: Our study highlights the potential of using ML techniques, particularly motifs and discords, to effectively detect dsCAN in patients with diabetes. This approach could be applied in large-scale screening of CAN, particularly to identify definite/severe CAN where cardiovascular risk factor modification may be initiated.


Assuntos
Inteligência Artificial , Neuropatias Diabéticas , Eletrocardiografia , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Neuropatias Diabéticas/diagnóstico , Neuropatias Diabéticas/fisiopatologia , Eletrocardiografia/métodos , Adulto , Idoso , Algoritmos , Aprendizado de Máquina , Máquina de Vetores de Suporte , Doenças do Sistema Nervoso Autônomo/diagnóstico , Doenças do Sistema Nervoso Autônomo/fisiopatologia , Cardiomiopatias Diabéticas/diagnóstico
19.
BMC Med Res Methodol ; 24(1): 127, 2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38834955

RESUMO

An electrocardiogram is a medical examination tool for measuring different patterns of heart blood flow circle either in the form of usual or non-invasive patterns. These patterns are useful for the identification of morbidity condition of the heart especially in certain conditions of heart abnormality and arrhythmia. Myocardial infarction (MI) is one of them that happened due to sudden blockage of blood by the cause of malfunction of heart. In electrocardiography (ECG) intensity of MI is highlighted on the basis of unusual patterns of T wave changes. Various studies have contributed for MI through T wave's classification, but more to the point of T wave has always attracted the ECG researchers. Methodology. This Study is primarily designed for proposing the combination of latest methods that are worked for the solutions of pre-defined research questions. Such solutions are designed in the form of the systematic review process (SLR) by following the Kitchen ham guidance. The literature survey is a two phase's process, at first phase collect the articles that were published in IEEE Xplore, Scopus, science direct and Springer from 2008 to 2023. It consist of steps; the first level is executed by filtrating the articles on the basis of keyword phase of title and abstract filter. Similarly, at two level the manuscripts are scanned through filter of eligibility criteria of articles selection. The last level belongs to the quality assessment of articles, in such level articles are rectified through evaluation of domain experts. Results. Finally, the selected articles are addressed with research questions and briefly discuss these selected state-of-the-art methods that are worked for the T wave classification. These address units behave as solutions to research problems that are highlighted in the form of research questions. Conclusion and future directions. During the survey process for these solutions, we got some critical observations in the form of gaps that reflected the other directions for researchers. In which feature engineering, different dependencies of ECG features and dimensional reduction of ECG for the better ECG analysis are reflection of future directions.


Assuntos
Eletrocardiografia , Infarto do Miocárdio , Humanos , Eletrocardiografia/métodos , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/fisiopatologia
20.
BMC Med Res Methodol ; 24(1): 96, 2024 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-38678178

RESUMO

One of the most common causes of death worldwide is heart disease, including arrhythmia. Today, sciences such as artificial intelligence and medical statistics are looking for methods and models for correct and automatic diagnosis of cardiac arrhythmia. In pursuit of increasing the accuracy of automated methods, many studies have been conducted. However, in none of the previous articles, the relationship and structure between the heart leads have not been included in the model. It seems that the structure of ECG data can help develop the accuracy of arrhythmia detection. Therefore, in this study, a new structure of Electrocardiogram (ECG) data was introduced, and the Graph Convolution Network (GCN), which has the possibility of learning the structure, was used to develop the accuracy of cardiac arrhythmia diagnosis. Considering the relationship between the heart leads and clusters based on different ECG poles, a new structure was introduced. In this structure, the Mutual Information(MI) index was used to evaluate the relationship between the leads, and weight was given based on the poles of the leads. Weighted Mutual Information (WMI) matrices (new structure) were formed by R software. Finally, the 15-layer GCN network was adjusted by this structure and the arrhythmia of people was detected and classified by it. To evaluate the performance of the proposed new network, sensitivity, precision, specificity, accuracy, and confusion matrix indices were used. Also, the accuracy of GCN networks was compared by three different structures, including WMI, MI, and Identity. Chapman's 12-lead ECG Dataset was used in this study. The results showed that the values of sensitivity, precision, specificity, and accuracy of the GCN-WMI network with 15 intermediate layers were equal to 98.74%, 99.08%, 99.97% & 99.82%, respectively. This new proposed network was more accurate than the Graph Convolution Network-Mutual Information (GCN-MI) with an accuracy equal to 99.71% and GCN-Id with an accuracy equal to 92.68%. Therefore, utilizing this network, the types of arrhythmia were recognized and classified. Also, the new network proposed by the Graph Convolution Network-Weighted Mutual Information (GCN-WMI) was more accurate than those conducted in other studies on the same data set (Chapman). Based on the obtained results, the structure proposed in this study increased the accuracy of cardiac arrhythmia diagnosis and classification on the Chapman data set. Achieving such accuracy for arrhythmia diagnosis is a great achievement in clinical sciences.


Assuntos
Arritmias Cardíacas , Eletrocardiografia , Redes Neurais de Computação , Humanos , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Eletrocardiografia/métodos , Algoritmos , Processamento de Sinais Assistido por Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA