RESUMO
The present review provides an update of the currently available (proto-) types of device-assisted enteroscopy (DAE). In recent years, newly designed double- and single-balloon enteroscopes have emerged. They aim to improve insertion depth into the small bowel, and they also allow more efficient endoscopic interventions. Nowadays, almost all conventional endoscopic procedures are feasible using DAE, opening the door to new indications. Recently, more data have become available on pediatric DAE, DAE-assisted colonoscopy, and DAE in patients with altered anatomy, including DAE-assisted endoscopic retrograde cholangiopancreatography and direct cholangioscopy. Although new enteroscopes are being developed, few comparative studies are available in order to define which DAE suits best for each indication. It is the duty of the international endoscopy community to set up clinical research projects to provide answers to these open questions.
Assuntos
Enteroscopia de Duplo Balão/instrumentação , Endoscópios Gastrointestinais/tendências , Desenho de Equipamento/tendências , Colangiopancreatografia Retrógrada Endoscópica/métodos , Enteroscopia de Duplo Balão/métodos , Segurança de Equipamentos , Feminino , Previsões , Humanos , Enteropatias/diagnóstico por imagem , Enteropatias/cirurgia , Japão , MasculinoRESUMO
Gastrointestinal endoscopy has undergone a remarkable expansion in its capabilities as a result of sophisticated technological advances in recent years. New imaging technologies, novel ablation and resection techniques, cutting-edge endoscope development and creative extraluminal applications have taken gastrointestinal endoscopy to an exciting new level. An update on some of these advances is presented for the physician audience.
Assuntos
Endoscópios Gastrointestinais/tendências , Endoscopia Gastrointestinal/tendências , Gastroenteropatias/diagnóstico , Animais , Endoscopia Gastrointestinal/métodos , Gastroenteropatias/cirurgia , HumanosRESUMO
BACKGROUND: Endoscopic retrograde cholangiopancreatography (ERCP) remains a challenge for endoscopists in patients with surgically altered anatomy of the upper gastrointestinal tract. Double-balloon enteroscopes (DBEs) have revolutionized the ability to access the small bowel. The indication for its therapeutic use is expanding to include ERCP for patients who have undergone small bowel reconstruction. Most of the published experiences in DBE-assisted ERCP have used conventional double-balloon enteroscopes that are 200 cm in length, which do not permit use of the standard ERCP accessories. The authors report their experience with DBE-assisted ERCP using a 'short' DBE in patients with surgically altered anatomy. METHODS: A retrospective review of patients with previous small bowel reconstruction who underwent ERCP with a 'short' DBE at the Centre for Therapeutic Endoscopy and Endoscopic Oncology (Toronto, Ontario) between February 2007 and November 2008 was performed. RESULTS: A total of 20 patients (10 men) with a mean age of 57.9 years (range 26 to 85 years) underwent 29 sessions of ERCP with a DBE. Six patients underwent Billroth II gastroenterostomy, seven patients Roux-en-Y hepaticojejunostomy, five patients Roux-en-Y gastrojejunostomy, one patient Roux-en-Y esophagojejunostomy and one patient a Whipple's operation with choledochojejunostomy. Some patients (n=12 [60%]) underwent previous attempts at ERCP in which the papilla of Vater or bilioenteric anastomosis could not be reached with either a duodenoscope or pediatric colonoscope. All procedures were performed with a commercially available DBE (working length 152 cm, distal end diameter 9.4 mm, channel diameter 2.8 mm). The procedures were performed under conscious sedation with intravenous midazolam, fentanyl and diazepam, except in one patient in whom general anesthesia was administered. Either the papilla of Vater or bilioenteric anastomosis was reached in 25 of 29 cases (86.2%) in a mean duration of 20.8 min (range 5 min to 82 min). Bile duct cannulation was successful in 24 of 25 cases in which the papilla or bilioenteric anastomosis was reached. Therapeutic interventions were successful in 15 patients (24 procedures) including sphincterotomy (n=7), stone extraction (n=9), biliary dilation (n=8), stent placement (n=9) and stent removal (n=8). The mean total duration of the procedures was 70.7 min (range 30 min to 117 min). There were no procedure-related complications. CONCLUSION: DBEs enable successful diagnostic and therapeutic ERCP in patients with a surgically altered anatomy of the upper gastrointestinal tract. It is a safe, feasible and less invasive therapeutic option in this group of patients. Standard 'long' DBEs have limitations of long working length and the need for modified ERCP accessories. 'Short' DBEs are equally as effective in reaching the target limb as standard 'long' DBEs, and overcomes some limitations of long DBEs to result in high success rates for endoscopic therapy.
Assuntos
Doenças Biliares/cirurgia , Colangiopancreatografia Retrógrada Endoscópica/instrumentação , Procedimentos Cirúrgicos do Sistema Digestório/métodos , Endoscópios Gastrointestinais , Intestino Delgado/patologia , Complicações Pós-Operatórias/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Doenças Biliares/diagnóstico , Doenças Biliares/fisiopatologia , Colangiopancreatografia Retrógrada Endoscópica/tendências , Procedimentos Cirúrgicos do Sistema Digestório/efeitos adversos , Endoscópios Gastrointestinais/normas , Endoscópios Gastrointestinais/tendências , Feminino , Humanos , Pessoa de Meia-Idade , Resultado do TratamentoRESUMO
With advancements in the development of flexible endoscopes and endoscopic devices and the increased demand for minimally invasive treatments, the indications of therapeutic endoscopy have been expanded. Methods of endoscopic treatment used for tissue removal, hemostasis, and dilatation are as follows. Endoscopic submucosal dissection (ESD) is considered the gold standard curative method for removal of gastrointestinal node-negative neoplasms, regardless of their size or the presence of ulcer formation. Laparoscopic endoscopic cooperative surgery (LECS), which incorporates ESD, was introduced for removal of lesions in deeper layers. Another technique is endoscopic full-thickness resection, which is challenging without the assistance of laparoscopy. In terms of hemostasis, management of iatrogenic bleeding after endoscopic treatment is an important issue. Shielding methods and suturing techniques have been introduced for large mucosal defects after ESD, and their efficacy has been investigated clinically. Peroral endoscopic myotomy (POEM) is a new alternative surgical approach for minimally invasive treatment of esophageal achalasia. Furthermore, endoscopic fundoplication after POEM was devised to prevent post-POEM gastroesophageal reflux disease. Many endoscopic treatments, including ESD, LECS, and POEM, have been introduced in Japan. With the aging of the population, more attention will be directed toward therapeutic endoscopy for elderly patients, because it is less invasive. Development of endoscopic treatments with expanded indications is expected.
Assuntos
Endoscópios Gastrointestinais/tendências , Endoscopia Gastrointestinal/instrumentação , Endoscopia Gastrointestinal/métodos , Mucosa Gástrica/cirurgia , Neoplasias Gastrointestinais/cirurgia , Laparoscopia/instrumentação , Laparoscopia/métodos , Endoscópios Gastrointestinais/efeitos adversos , Endoscopia Gastrointestinal/efeitos adversos , Endoscopia Gastrointestinal/tendências , Acalasia Esofágica/cirurgia , Feminino , Fundoplicatura/métodos , Refluxo Gastroesofágico/prevenção & controle , Hemostase Endoscópica/instrumentação , Hemostase Endoscópica/métodos , Humanos , Laparoscopia/efeitos adversos , Masculino , Miotomia/efeitos adversos , Miotomia/instrumentação , Miotomia/métodos , Complicações Pós-Operatórias/prevenção & controle , Hemorragia Pós-Operatória/etiologia , Hemorragia Pós-Operatória/cirurgiaRESUMO
PURPOSE OF REVIEW: The continued application of innovative imaging systems to endoscopic procedures has vastly improved the detection of indiscriminant tissue anomalies. This article describes the fundamental principles of these technologies and reviews the advances of each over the past 18 months, considering their utility in the diagnosis and surveillance of various gastrointestinal diseases. RECENT FINDINGS: Through a combination of novel optics, processors and filters, real-time high-resolution contrast endoscopy provides increased visual data without greater procedure duration or difficulty. Optical contrast techniques incorporated into endoscopes, such as narrow band imaging (Olympus), i-Scan (Pentax), and Fujinon Intelligent Chromo Endoscopy, have become standard of care for many endoscopists. These technologies, as well as autofluorescence imaging, potentially improve detection of mucosal abnormalities, serving as 'red flag' tools for the evaluation of wide areas of mucosa. In addition, a number of promising devices allow virtual histology and in-vivo diagnosis, thereby directing biopsies and potentially guiding concurrent interventions. One such technology, confocal laser endomicroscopy, continues to establish its role in clinical practice. Because of inherent shortcomings affecting each modality's sensitivity and specificity, the coupling of various devices, as with endoscopic trimodal imaging, has shown great promise; however, most are not widely available and not definitively proven to be superior to more established techniques. Emerging technologies, including in-vivo molecular tagging, provide a powerful means of detecting disease without reliance on morphologic diagnostic criteria. SUMMARY: Endoscopy continues to evolve from a field that previously allowed only macroscopic imaging dependent on subsequent pathology to one that allows real-time in-vivo diagnosis. Although the promise of enhanced endoscopic technologies seems limitless, practical and technological considerations slow their adoption into the standard of care.
Assuntos
Endoscópios Gastrointestinais/tendências , Endoscopia Gastrointestinal/tendências , Gastroenteropatias/diagnóstico , Aumento da Imagem/métodos , Mucosa Intestinal/patologia , Desenho de Equipamento , Humanos , Reprodutibilidade dos TestesRESUMO
Extraordinary developments have occurred in the field of endoscopy over the past 40 years. The era that began with the fiberoptic endoscope (fiberscope) has now moved to the videoscope and, more recently, to the capsule endoscope. Videoendoscopy will remain the major form of endoscopy for the next 5-10 years but, thereafter, diagnostic procedures including colonoscopy will increasingly be performed by capsule endoscopy. This change will be largely driven by patient preference rather than superior results from capsule studies. Image analysis of capsule studies will be accelerated by software that highlights abnormal areas and, by 2025, capsule studies will be 'read' by computer. For the next decade, more complex therapeutic procedures will be performed by a new group of therapeutic endoscopists using advanced videoscopes. Several new therapeutic procedures will emerge but natural orifice transluminal approaches will need to compete with advances in laparoscopic techniques. It is also likely that health administrators faced with escalating medical costs will demand that new and more expensive procedures not only facilitate patient care but result in superior health outcomes.
Assuntos
Doenças do Sistema Digestório/diagnóstico , Doenças do Sistema Digestório/terapia , Endoscópios Gastrointestinais/tendências , Endoscopia do Sistema Digestório/tendências , Endossonografia/tendências , Desenho de Equipamento , Humanos , Processamento de Imagem Assistida por ComputadorRESUMO
Endocytoscopy has the potential to reduce the need for histologic examination of biopsy specimens in cases of esophageal squamous cell carcinoma. Up to now, two types of endocytoscope have been used: the probe type and the integrated type. In this study we examined the utility of a newly developed endocytoscope, the 'GIF-Y0002,' which has a single lens allowing consecutive magnification from the conventional endoscopy level up to ×380. Using the GIF-Y0002, we examined 24 examples of normal esophageal mucosa to clarify the appearance of the microvasculature of the normal squamous epithelium in vivo. We also examined 11 cases of esophageal cancer in the same way, employing methylene blue as a vital dye to stain the surface cells. In normal squamous epithelium, we clarified the relationship between the subepithelial capillary network, IPCLs and subepithelial venules. With methylene blue staining, we observed typical squamous cells (low nuclear density and low N/C ratio without nuclear abnormality). When cancerous lesions were observed using lower-power magnification, we were able to visualize their microvascular architecture to the same extent as when conventional magnifying endoscopy was used. Furthermore, at higher magnification, we were able to visualize the features of blood flow in both superficial and advanced cancer. Methylene blue staining revealed an increase of nuclear density in all cases of cancer. The pathologist agreed to omit biopsy histology in 81.8% (9/11) of cancer cases considering the nuclear density and nuclear abnormality. The GIF-Y0002 provides information on cell abnormality in addition to the features revealed by currently available magnifying endoscopy.
Assuntos
Carcinoma de Células Escamosas , Endoscópios Gastrointestinais , Neoplasias Esofágicas , Esofagoscopia/instrumentação , Microscopia , Biópsia , Carcinoma de Células Escamosas/irrigação sanguínea , Carcinoma de Células Escamosas/ultraestrutura , Corantes , Endoscópios Gastrointestinais/estatística & dados numéricos , Endoscópios Gastrointestinais/tendências , Desenho de Equipamento , Neoplasias Esofágicas/irrigação sanguínea , Neoplasias Esofágicas/patologia , Neoplasias Esofágicas/ultraestrutura , Estudos de Avaliação como Assunto , Humanos , Azul de Metileno , Microscopia/estatística & dados numéricos , Microscopia/tendências , Estadiamento de Neoplasias , Neovascularização Patológica/diagnósticoRESUMO
The United European Gastroenterology Week (UEGW) of 2006 offered an interesting variety of topics, and included many randomized studies that had not been previously presented at major meetings. Papers presented at plenary sessions will be given some priority in the following paper, whereas the selection of topics from abstracts, on the basis of poster presentations, has been more limited, necessarily reflecting to some extent the personal taste of the reviewer.
Assuntos
Congressos como Assunto , Endoscópios Gastrointestinais/tendências , Gastroenterologia/métodos , Sociedades Médicas , Europa (Continente) , HumanosRESUMO
Capsule endoscopy has recently been introduced to explore endoscopically the whole small intestine, fulfilling a gap between examinations of the upper and lower gastrointestinal tract. The technique consists of a miniaturized endoscope, embedded in a swallowable capsule that is propulsed by peristalsis and achieves the journey to the right colon in five to eight hours. Images captured by the capsule are recorded on a hard drive worn in a belt by the patient. The main indication for capsule examination is the examination of the small bowel to find a bleeding lesion in patients with obscure bleeding. Several studies have shown that the diagnostic yield of capsule endoscopy is superior to that of push enteroscopy in this indication. Other possible indications are patients with suspected intestinal location of Crohn's disease, familial adenomatous polyposis, complicated coeliac disease and lesions due NSAIDs. The review contains information on the technical aspects of capsule endoscopy and discusses the indications. Issues of safety and tolerance are also discussed.
Assuntos
Endoscópios Gastrointestinais/tendências , Endoscopia Gastrointestinal/métodos , Hemorragia Gastrointestinal/diagnóstico , Intestino Delgado/patologia , Cápsulas , Ensaios Clínicos como Assunto , HumanosRESUMO
Swallowable biotelemetry systems are one kind of implantable biotelemetry systems. The research about swallowable biotelemetry systems is rapidly growing recently because they can be used to measure physiological and pathological parameters of human gastrointestinal tracts in vivo and they significantly improve patient comfort. This paper presents the current research of swallowable biotelemetry systems domestically and abroad. The development trend of these systems is analyzed at the end of the paper.
Assuntos
Endoscópios Gastrointestinais , Monitorização Fisiológica/instrumentação , Telemetria/instrumentação , Cápsulas , Eletrônica Médica/instrumentação , Endoscópios Gastrointestinais/tendências , Desenho de Equipamento , Trato Gastrointestinal/fisiologia , Humanos , Monitorização Fisiológica/métodos , Telemetria/métodosAssuntos
Endoscópios Gastrointestinais/tendências , Endoscopia do Sistema Digestório , Neoplasias Gastrointestinais/diagnóstico , Aumento da Imagem/métodos , Meios de Contraste , Detecção Precoce de Câncer , Endoscopia do Sistema Digestório/instrumentação , Endoscopia do Sistema Digestório/métodos , Desenho de Equipamento/tendências , Tecnologia de Fibra Óptica/instrumentação , Neoplasias Gastrointestinais/terapia , Humanos , Interpretação de Imagem Assistida por Computador/instrumentação , Cirurgia Assistida por ComputadorRESUMO
Since 1.5 years wireless enteroscopy with the GivenM2A-capsule has been tested clinically. Wireless capsule-enteroscopy (WCE) has already contributed significantly to the understanding of patients with obscure intestinal symptoms. Series of occult bleeders show that WCE detects lesions in 60%, whereas enterography only in 15%, and push-enteroscopy in 25%. Lesions detected are angiodysplasia in 55%, ulcerations in 14%, apthoid lesions and erosions in 11%, tumours in 8%. Active bleeding was seen in 43%. In patients with Crohn's disease further information on extent of disease and type of lesions is gained, mainly seen as erosions in 64%. WCE in hereditary polyposis disclosed more and bigger lesions, and in celiac enteropathy villous atrophy and scalloping of the mucous membrane is readily identified. Software to locate the capsule in the gastrointestinal tract is recently launched together with a graphic display of capsule track and transit times. Soon displays for motility and pressure will follow. Capsule adaptation for screening for Barrett's esophagus and colon cancer might come true.
Assuntos
Cápsulas , Endoscopia Gastrointestinal/métodos , Intestino Delgado/patologia , Gravação em Vídeo , Cápsulas/efeitos adversos , Doença de Crohn/patologia , Deglutição , Duodenopatias/patologia , Endoscópios Gastrointestinais/tendências , Humanos , Mucosa Intestinal/patologia , SoftwareAssuntos
Cápsulas Endoscópicas , Endoscópios Gastrointestinais , Enteropatias/diagnóstico , Intestino Delgado , Cápsulas Endoscópicas/tendências , Endoscópios Gastrointestinais/tendências , Endoscopia Gastrointestinal/tendências , Hemorragia Gastrointestinal/diagnóstico , Hemorragia Gastrointestinal/etiologia , Humanos , Enteropatias/patologiaAssuntos
Endoscópios Gastrointestinais , Endoscopia Gastrointestinal/tendências , Enteropatias/terapia , Intestino Delgado , Cateterismo , Colangiopancreatografia Retrógrada Endoscópica , Endoscópios Gastrointestinais/tendências , Humanos , Enteropatias/diagnóstico , Enteropatias/patologia , Pólipos Intestinais/cirurgia , Intestino Delgado/anatomia & histologia , StentsRESUMO
AIM: To study the current application situation of gastrointestinal (GI) endoscopy in mainland China. METHODS: From 12 August, 2011 to 15 February, 2012, draft questionnaires were sent by e-mail to 289 hospital-based GI endoscopy units, including units with three levels (provincial, prefecture and county level) in mainland China. All the surveyed GI endoscopy units were state-owned and hospital-based. Proportions were compared using χ² tests. Comparisons between groups were performed using the Mann-Whitney U test. A probability of P < 0.05 was considered to represent a statistically significant difference. RESULTS: Based on satisfactory replies, 169/279 (60.6%) of units were enrolled in the survey, which covered 28 provinces (90.3%, 28/31) in mainland China. Compared with published survey data, the number of GI endoscopes per unit has increased by nearly three times (from 2.9 to 9.3) in the past decade. About 33 of 169 (19.5%) endoscopy units possessed an X-ray machine, which was mainly owned by provincial endoscopy units (43.2%, 19/44). Video capsule endoscopes, which were almost unavailable ten years ago, were owned by 20.7% (35/169) of GI endoscopy units. Endoscopic submucosal dissection could be performed by 36.4% (19/44) of the provincial units, which was significantly higher than the prefecture level (9.9%, P < 0.01) and county level (0.0%, P < 0.01) units, respectively. CONCLUSION: Rapid development in GI endoscopy has been made in mainland China, and major diagnostic endoscopes and therapeutic endoscopy procedures are predominantly used in large endoscopy units.
Assuntos
Endoscopia Gastrointestinal/tendências , Padrões de Prática Médica/tendências , Cápsulas Endoscópicas/tendências , Endoscopia por Cápsula/tendências , Distribuição de Qui-Quadrado , China , Difusão de Inovações , Endoscópios Gastrointestinais/tendências , Pesquisas sobre Atenção à Saúde , Humanos , Inquéritos e Questionários , Fatores de TempoRESUMO
Background: Direct percutaneous endoscopic jejunostomy (DPEJ) is a useful method to provide enteral nutrition to individuals when gastric feeding is not possible or contraindicated. The aim of this study was to analyze the efficacy and safety of DPEJ tube placement with the Gauderer-Ponsky technique by the pull method, using single-balloon enteroscopy (SBE) without fluoroscopy. Methods: This is a retrospective analysis of patients undergoing SBE for DPEJ placement in a referral hospital between January 2010 and March 2016. Technical success, clinical success and procedure related complications were recorded. Results: Twenty-three patients were included (17 males, median age 71 years, range 37-93 years). The most frequent indications for DPEJ were gastroesophageal cancer (n = 10) and neurological disease (n = 8). Eighty-seven percent of the patients had a contraindication to percutaneous endoscopic gastrostomy (PEG) and PEG was unsuccessful in the remaining patients. The technical success rate was 83% (19/23), transillumination was not possible in three patients and an accidental exteriorization of the bumper resulting in a jejunal perforation occurred in one patient. The clinical success was 100% (19/19). The median follow-up was five months (range 1-35 months). Apart from the case of jejunal perforation and the two cases of accidental exteriorization, there were no other complications during follow-up. The 6-month survival was 65.8% and the 1-year survival was 49.3%. Conclusion: DPEJ can be carried out successfully via SBE without fluoroscopy with a low rate of significant adverse events. Although, leaving the overtube in place during the bumper pulling can be useful for distal jejunal loops, it can be safely removed in proximal loops to minimize complications (AU)
No disponible
Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Jejunostomia/métodos , Fluoroscopia , Nutrição Enteral/métodos , Gastrostomia/métodos , Estudos Retrospectivos , Estimativa de Kaplan-Meier , Endoscópios Gastrointestinais/tendênciasRESUMO
Advances in modern enteroscopy have been largely due to endoscope development but also through the improved availability of endoscopic accessories along with improved understanding in their application. Device assisted enteroscopy began with the double balloon system in 2001 and was quickly followed by single balloon enteroscopy and spiral enteroscopy. These tools revolutionised deep small bowel endoscopy and allowed for the delivery of virtually all known therapeutic endoscopy intervention to almost all segments of the small bowel. This review covers the types of interventions in regards to indications, methods and their safety profiles as well as reviewing the various device assisted endoscopes available and their attributes.