Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 814
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Circulation ; 140(25): e944-e963, 2019 12 17.
Artigo em Inglês | MEDLINE | ID: mdl-31694402

RESUMO

The widespread use of cardiac implantable electronic devices and wearable monitors has led to the detection of subclinical atrial fibrillation in a substantial proportion of patients. There is evidence that these asymptomatic arrhythmias are associated with increased risk of stroke. Thus, detection of subclinical atrial fibrillation may offer an opportunity to reduce stroke risk by initiating anticoagulation. However, it is unknown whether long-term anticoagulation is warranted and in what populations. This scientific statement explores the existing data on the prevalence, clinical significance, and management of subclinical atrial fibrillation and identifies current gaps in knowledge and areas of controversy and consensus.


Assuntos
American Heart Association , Fibrilação Atrial/diagnóstico , Desfibriladores Implantáveis/normas , Conhecimentos, Atitudes e Prática em Saúde , Marca-Passo Artificial/normas , Dispositivos Eletrônicos Vestíveis/normas , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/terapia , Desfibriladores Implantáveis/tendências , Humanos , Marca-Passo Artificial/tendências , Fatores de Risco , Estados Unidos/epidemiologia , Dispositivos Eletrônicos Vestíveis/tendências
2.
Pediatr Cardiol ; 41(4): 801-808, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32166409

RESUMO

Magnetic resonance imaging (MRI) of patients with pacemakers remains concerning because of possible magnetic field effects on the device. Many pacemaker models are labeled as non-conditional, or contraindicated for MRI, or do not have any specific safety guidelines listed. This study describes our experience with pacemaker function and adverse events in pediatric and young adult patients after clinically indicated MRI scanning at 1.5 Tesla (T). We hypothesized that generator battery voltage, pacemaker lead threshold, and lead impedance would not be altered by MRI. This was a retrospective review of Children's Wisconsin clinical MRI data for all patients with pacemakers scanned between January 1, 2010 and March 31, 2018. Pacemakers were interrogated by the Electrophysiology Team before and immediately after MRI and at outpatient follow up. Twenty-one patients underwent forty-four MRI scans. No significant immediate changes were seen in any pacemaker parameter for any manufacturer/model/lead at the time of MRI. At first clinical follow up post MRI, (median 4.4 months, range 0.2-12.3), battery voltage was reduced (2.78 V pre-MRI versus 2.77 V at follow up, p = 0.02), but there were no other significant changes. No adverse events were noted. Pediatric patients with pacemakers, including those with epicardial leads, can be scanned at 1.5 T safely without alteration in pacemaker function. Using appropriate precautions, pediatric patients with pacemakers can be imaged with MRI.


Assuntos
Imageamento por Ressonância Magnética/efeitos adversos , Marca-Passo Artificial/normas , Criança , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Estudos Retrospectivos , Medição de Risco , Adulto Jovem
3.
Anesthesiology ; 130(4): 530-540, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30601218

RESUMO

WHAT WE ALREADY KNOW ABOUT THIS TOPIC: Electromagnetic interference from monopolar electrosurgery may disrupt implantable cardioverter defibrillators.Current management recommendations by the American Society of Anesthesiologists and Heart Rhythm Society are based on expert clinical opinion since there is a paucity of data regarding the risk of electromagnetic interference to implantable cardioverter defibrillators during surgery. WHAT THIS ARTICLE TELLS US THAT IS NEW: With protocolized electrosurgery dispersive electrode positioning in patients with implantable cardioverter defibrillators, the risk of clinically meaningful electromagnetic interference was 7% in above-the-umbilicus noncardiac surgery and 0% in below-the-umbilicus surgery. In cardiac surgery, clinically meaningful electromagnetic interference with use of an underbody dispersive electrode was 29%.Despite protocolized dispersive electrode positioning, the risk of electromagnetic interference in above-the-umbilicus surgery is high, supporting recommendations to suspend antitachycardia therapy when monopolar electrosurgery is used above the umbilicus.With protocolized dispersive electrode positioning, the risk of electromagnetic interference in below-the-umbilicus surgery is negligible, implying that suspending antitachycardia therapy might be unnecessary in these cases.With an underbody dispersive electrode, the risk of electromagnetic interference in cardiac surgery is high. BACKGROUND: The goal of this study was to determine the occurrence of intraoperative electromagnetic interference from monopolar electrosurgery in patients with an implantable cardioverter defibrillator undergoing surgery. A protocolized approach was used to position the dispersive electrode. METHODS: This was a prospective cohort study including 144 patients with implantable cardioverter defibrillators undergoing surgery between May 2012 and September 2016 at an academic medical center. The primary objectives were to determine the occurrences of electromagnetic interference and clinically meaningful electromagnetic interference (interference that would have resulted in delivery of inappropriate antitachycardia therapy had the antitachycardia therapy not been programmed off) in noncardiac surgeries above the umbilicus, noncardiac surgeries at or below the umbilicus, and cardiac surgeries with the use of an underbody dispersive electrode. RESULTS: The risks of electromagnetic interference and clinically meaningful electromagnetic interference were 14 of 70 (20%) and 5 of 70 (7%) in above-the-umbilicus surgery, 1 of 40 (2.5%) and 0 of 40 (0%) in below-the-umbilicus surgery, and 23 of 34 (68%) and 10 of 34 (29%) in cardiac surgery. Had conservative programming strategies intended to reduce the risk of inappropriate antitachycardia therapy been employed, the occurrence of clinically meaningful electromagnetic interference would have been 2 of 70 (2.9%) in above-the-umbilicus surgery and 3 of 34 (8.8%) in cardiac surgery. CONCLUSIONS: Despite protocolized dispersive electrode positioning, the risks of electromagnetic interference and clinically meaningful electromagnetic interference with surgery above the umbilicus were high, supporting published recommendations to suspend antitachycardia therapy whenever monopolar electrosurgery is used above the umbilicus. For surgery below the umbilicus, these risks were negligible, implying that suspending antitachycardia therapy is likely unnecessary in these patients. For cardiac surgery, the risks of electromagnetic interference and clinically meaningful electromagnetic interference with an underbody dispersive electrode were high. Conservative programming strategies would not have eliminated the risk of clinically meaningful electromagnetic interference in either noncardiac surgery above the umbilicus or cardiac surgery.


Assuntos
Desfibriladores Implantáveis/normas , Eletrodos Implantados/normas , Fenômenos Eletromagnéticos , Eletrocirurgia/normas , Marca-Passo Artificial/normas , Adulto , Idoso , Desfibriladores Implantáveis/efeitos adversos , Eletrodos Implantados/efeitos adversos , Eletrocirurgia/instrumentação , Eletrocirurgia/métodos , Feminino , Cardiopatias/fisiopatologia , Cardiopatias/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial/efeitos adversos
4.
Int Heart J ; 60(3): 768-771, 2019 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-31019171

RESUMO

A 91-year-old woman was admitted to our hospital for treatment of congestive heart failure with severe aortic stenosis. After admission, she developed a high fever due to pneumonia and worsened heart failure. We could not perform transcatheter aortic valve implantation (TAVI) because of active infection; therefore, retrograde balloon aortic valvuloplasty (BAV) was urgently performed. A complete atrioventricular block and severe functional mitral regurgitation appeared suddenly after BAV in the absence of mechanical disorders. Her condition improved after several days in our intensive care unit. Pacemaker implantation and TAVI were then performed, and the patient was discharged from our hospital. MR could sometimes exacerbate after BAV in clinical practice; therefore, we set out to report this case.


Assuntos
Estenose da Valva Aórtica/complicações , Bloqueio Atrioventricular/diagnóstico , Valvuloplastia com Balão/efeitos adversos , Insuficiência da Valva Mitral/diagnóstico , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/terapia , Bloqueio Atrioventricular/etiologia , Bloqueio Atrioventricular/fisiopatologia , Feminino , Humanos , Insuficiência da Valva Mitral/etiologia , Marca-Passo Artificial/normas , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
5.
Int Heart J ; 60(1): 12-18, 2019 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-30518714

RESUMO

Emery-Dreifuss muscular dystrophy (EDMD) is a group of hereditary muscular dystrophy syndrome caused by deficiency of genes encoding nuclear envelope proteins. Patients having EDMD show the triad of muscle dystrophy, joint contracture, and cardiac disease. In almost all patients, cardiac involvement is prevalent and is the most severe aspect of EDMD. Cardiac disease is predominantly shown by conduction defects, atrial fibrillation/flutter, and atrial standstill. Sudden death and heart failure because of left ventricular dysfunction are important causes of mortality, particularly in those patients that have the LMNA mutation. Medical treatment of EDMD is limited to addressing symptoms and ambulation support; moreover, pacemaker implantation is necessary when there are severe conduction defects and bradycardia occurs. Note that automated defibrillation devices may be considered for those patients who have a high risk of sudden death, rate, or rhythm control. Also, anticoagulation should be initiated in those patients who have atrial fibrillation/flutter. Thus, for optimal management, a multidisciplinary approach is required.


Assuntos
Fibrilação Atrial/terapia , Distrofia Muscular de Emery-Dreifuss/genética , Disfunção Ventricular Esquerda/mortalidade , Anormalidades Múltiplas/epidemiologia , Anticoagulantes/uso terapêutico , Fibrilação Atrial/complicações , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/epidemiologia , Cardiomiopatias/fisiopatologia , Fissura Palatina/complicações , Fissura Palatina/epidemiologia , Contratura/complicações , Contratura/epidemiologia , Morte Súbita/epidemiologia , Feminino , Doenças Genéticas Inatas/fisiopatologia , Átrios do Coração/anormalidades , Átrios do Coração/fisiopatologia , Bloqueio Cardíaco/fisiopatologia , Cardiopatias/complicações , Cardiopatias/epidemiologia , Humanos , Hidrocefalia/complicações , Hidrocefalia/epidemiologia , Comunicação Interdisciplinar , Deformidades Congênitas dos Membros/complicações , Deformidades Congênitas dos Membros/epidemiologia , Masculino , Distrofias Musculares/complicações , Distrofias Musculares/epidemiologia , Distrofia Muscular de Emery-Dreifuss/complicações , Distrofia Muscular de Emery-Dreifuss/diagnóstico , Distrofia Muscular de Emery-Dreifuss/terapia , Marca-Passo Artificial/normas , Disfunção Ventricular Esquerda/epidemiologia
6.
Zhongguo Yi Liao Qi Xie Za Zhi ; 43(4): 235-237, 2019 Jul 30.
Artigo em Zh | MEDLINE | ID: mdl-31460710

RESUMO

In order to improve the accuracy of the pacemaker's parameter adjustment and to avoid the surgical replacement of the pacemaker when the battery is exhausted, this paper designs a novel single-chamber pacemaker circuit based on low-power single-chip microcomputer. The circuit uses digital control to accurately control the amplitude, pulse width and frequency of the pacing pulse. The circuit is also designed with wireless charging function, and wireless communication with the programmer can wirelessly charge the pacemaker and know the charging information in real time. Wireless charging function can reduce the number of times the patient replaces the pacemaker or even completely avoid it.


Assuntos
Desenho de Equipamento , Marca-Passo Artificial , Fontes de Energia Elétrica , Humanos , Marca-Passo Artificial/normas , Marca-Passo Artificial/tendências
7.
Europace ; 20(3): 555-559, 2018 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-29360974

RESUMO

The purpose of this European Heart Rhythm Association (EHRA) survey is to provide an overview of the current use of leadless pacemakers (LLPM) across a broad range of European centres. An online questionnaire was sent to centres participating in the EHRA Electrophysiology Research Network. Questions dealt with standards of care and policies used for patient management, indications, and techniques of implantation of LLPM. In total, 52 centres participated in the survey. Most (86%) reported using LLPM, although 82% of these centres implanted <30 LLPM devices during the last 12 months. Non-availability (36%), lack of reimbursement (55%), and cost of the device (91%) were factors limiting the use of LLPM. The most commonly reported indications for LLPM were permanent atrial fibrillation (83%), a history of complicated conventional pacemaker (87%), or an anticipated difficult vascular access (91%). Implantation of LLPM is perceived as an easy-to-do and safe procedure by most implanters (64%), while difficult or risky in 28%, and comparable to conventional pacemakers by only a few (8%). Local vascular complications were the most frequently reported major problems (28%), but a significant number of respondents (36%) have never encountered any issue after LLPM implantation. Although cost and reimbursement issues strongly influence the use of LLPM, most respondents (72%) anticipate a significant increase in device utilization within next 2 years.


Assuntos
Arritmias Cardíacas/terapia , Estimulação Cardíaca Artificial/tendências , Cardiologistas/tendências , Marca-Passo Artificial/tendências , Padrões de Prática Médica/tendências , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/fisiopatologia , Estimulação Cardíaca Artificial/normas , Cardiologistas/normas , Desenho de Equipamento , Europa (Continente)/epidemiologia , Previsões , Fidelidade a Diretrizes/tendências , Pesquisas sobre Atenção à Saúde , Disparidades em Assistência à Saúde/tendências , Humanos , Marca-Passo Artificial/normas , Guias de Prática Clínica como Assunto , Padrões de Prática Médica/normas
8.
J Cardiothorac Vasc Anesth ; 32(4): 1871-1884, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29217253

RESUMO

With the advent of "wireless" endocardial pacing, the subcutaneous implantable cardioverter defibrillator, and leadless pacemakers comes an added layer of complexity to the perioperative management of cardiovascular implantable electronic devices (CIED). Since no formal recommendations currently exist for these new CIED technologies, preoperative identification of these devices, understanding their functionality, and developing an individualized perioperative management plan are imperative for the anesthesiologist. The following review is intended to provide the background information required to devise a successful perioperative management strategy for newer CIEDs.


Assuntos
Anestesiologistas/normas , Desfibriladores Implantáveis/normas , Marca-Passo Artificial/normas , Assistência Perioperatória/normas , Anestesiologistas/educação , Desfibriladores Implantáveis/efeitos adversos , Humanos , Marca-Passo Artificial/efeitos adversos , Assistência Perioperatória/métodos
9.
J Cardiothorac Vasc Anesth ; 32(3): 1101-1111, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29482939

RESUMO

With increasing use of cardiovascular implantable electronic devices, the need for lead extractions has increased to an annual volume of more than 10,000 extractions worldwide. This article provides a focused clinical commentary on the perioperative management, identification, and treatment of life-threatening complications associated with lead extractions. In addition, a summary of indications, techniques, and lead extraction complications is provided. Although uncommon, lead extractions are associated with a consistent rate of major procedure-related complications and mortality. Major life-threatening complications include vascular laceration, cardiac avulsion, hemothorax, pericardial effusion, and cardiac arrest. Comprehensive preoperative risk assessment and adequate planning and preparedness are crucial to decreasing all procedure-related adverse events. The location of the procedure (electrophysiology suite v hybrid operating room) and the nature of cardiac surgical backup are determined after meticulous risk stratification. In addition to decisions on vascular access, invasive monitoring, and modality of rhythm support, transesophageal echocardiography plays a crucial role in early diagnosis, timely management, and potential prevention of these complications.


Assuntos
Anestesiologistas , Desfibriladores Implantáveis , Remoção de Dispositivo/métodos , Assistência Perioperatória/métodos , Anestesiologistas/normas , Desfibriladores Implantáveis/normas , Remoção de Dispositivo/normas , Ecocardiografia Transesofagiana/métodos , Ecocardiografia Transesofagiana/normas , Eletrodos Implantados/normas , Humanos , Marca-Passo Artificial/normas , Assistência Perioperatória/normas , Medição de Risco
10.
J Cardiovasc Electrophysiol ; 28(12): 1468-1474, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28960745

RESUMO

INTRODUCTION: The recent MagnaSafe Registry demonstrated safety of nonthoracic magnetic resonance imaging (MRI) with nonconditional cardiac implantable electronic devices (CIEDs). However, independent validation and extension to thoracic MRIs are needed. METHODS AND RESULTS: We prospectively examined 178 consecutive patients with CIEDs who underwent 212 MRI scans (62 with implantable cardioverter/defibrillators) for clinical reasons between February 2014 and August 2016. Scans were done in standard modes with a limit of 2 W/kg. Pacing modes were ODO or OVO for intrinsic rates > 40 and DOO or VOO for rates ≤ 40. Patients were cleared prescan by both radiology and cardiology, and pre- and postscan CIED interrogations were performed. Primary outcome events were death and generator or lead failure. Secondary events included battery voltage loss > 0.04 V, decrease in P wave voltage > 50% or R wave voltage > 25%, threshold increase of > 0.5 V, and impedance change > 50 Ω. Scan sites were 87 (41%) C-spine/head/neck, 28 (13%) T-spine/cardiac/shoulder (thoracic), 69 (33%) L-spine/abdomen/pelvis, and 28 (13%) lower extremity. No primary or secondary outcome events occurred, and no periscan disruption of pacing was noted. CONCLUSION: In a real-world MRI experience in patients with CIEDs representing a broad range of models, types, and scan sites (including thoracic scans), no adverse safety signals were noted. This experience validates and extends that of the large but inclusion-restricted MagnaSafe Registry, profiles MRI scanning in CIED patients in general clinical practice, and argues against replacing nonconditional with conditional devices when MRI is performed in a carefully controlled environment.


Assuntos
Arritmias Cardíacas/diagnóstico por imagem , Desfibriladores Implantáveis/tendências , Desenho de Equipamento/tendências , Imageamento por Ressonância Magnética/tendências , Sistema de Registros , Adulto , Idoso , Idoso de 80 Anos ou mais , Arritmias Cardíacas/fisiopatologia , Arritmias Cardíacas/cirurgia , Desfibriladores Implantáveis/normas , Desenho de Equipamento/métodos , Desenho de Equipamento/normas , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/normas , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial/normas , Marca-Passo Artificial/tendências , Estudos Prospectivos , Sistema de Registros/normas
11.
Circ J ; 81(11): 1589-1595, 2017 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-28566657

RESUMO

BACKGROUND: A global study designed to demonstrate the safety and efficacy of a transcatheter pacing system included 38 Japanese patients enrolled at 4 sites. Subgroup analysis to evaluate the performance of the leadless intracardiac transcatheter pacing system in Japanese patients was performed.Methods and Results:Safety and efficacy outcomes, patient and implant procedure characteristics, and patient and physician acceptability from the Japanese population were compared with those from outside Japan. Differences in patient characteristics, implant procedure characteristics and patient acceptability were observed. There were no major complications in Japanese patients and pacing thresholds remained low and stable throughout follow-up. There were no observable differences between Japanese patients and patients from outside Japan in the freedom from major complication rate at 12-months post-implant (100.0% vs. 95.7%, P=0.211) or physician acceptability. CONCLUSIONS: Although some differences in specific baseline characteristics, such as body size and pacing indication, and in implant procedure characteristics, including anticoagulation strategy and hospitalization period, were observed in the Japanese patients, transcatheter pacemaker performance was similar to that in the global trial. (Clinical Trial Registration: ClinicalTrials.gov ID NCT02004873.).


Assuntos
Desenho de Equipamento , Marca-Passo Artificial/normas , Adulto , Idoso , Idoso de 80 Anos ou mais , Anticoagulantes/uso terapêutico , Estimulação Cardíaca Artificial , Feminino , Hospitalização , Humanos , Japão , Masculino , Pessoa de Meia-Idade , Padrões de Prática Médica , Implantação de Prótese , Resultado do Tratamento , Adulto Jovem
12.
Europace ; 18(11): 1740-1747, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26941338

RESUMO

AIMS: The subcutaneous implantable cardioverter-defibrillator (S-ICD) and leadless pacemaker (LP) are evolving technologies that do not require intracardiac leads. However, interactions between these two devices are unexplored. We investigated the feasibility, safety, and performance of combined LP and S-ICD therapy, considering (i) simultaneous device-programmer communication, (ii) S-ICD rhythm discrimination during LP communication and pacing, and (iii) post-shock LP performance. METHODS AND RESULTS: The study consists of two parts. Animal experiments: Two sheep were implanted with both an S-ICD and LP (Nanostim, SJM), and the objectives above were tested. Human experience: Follow-up of one S-ICD patient with bilateral subclavian occlusion who received an LP and two LP (all Nanostim, SJM) patients (without S-ICD) who received electrical cardioversion (ECV) are presented. Animal experiments : Simultaneous device-programmer communication was successful, but LP-programmer communication telemetry was temporarily lost (2 ± 2 s) during ventricular fibrillation (VF) induction and 4/54 shocks. Leadless pacemaker communication and pacing did not interfere with S-ICD rhythm discrimination. Additionally, all VF episodes (n = 12/12), including during simultaneous LP pacing, were detected and treated by the S-ICD. Post-shock LP performance was unaltered, and no post-shock device resets or dislodgements were observed (24 S-ICD and 30 external shocks). Human experience : The S-ICD/LP patient showed adequate S-ICD sensing during intrinsic rhythm, nominal, and high-output LP pacing. Two LP patients (without S-ICD) received ECV during follow-up. No impact on performance or LP dislodgements were observed. CONCLUSION: Combined LP and S-ICD therapy appears feasible in all animal experiments (n = 2) and in one human subject. No interference in sensing and pacing during intrinsic and paced rhythm was noted in both animal and human subjects. However, induced arrhythmia testing was not performed in the patient. Defibrillation therapy did not seem to affect LP function. More data on safety and performance are needed.


Assuntos
Arritmias Cardíacas/terapia , Desfibriladores Implantáveis/normas , Cardioversão Elétrica/instrumentação , Marca-Passo Artificial/normas , Idoso , Idoso de 80 Anos ou mais , Animais , Terapia Combinada , Eletrocardiografia , Desenho de Equipamento , Seguimentos , Humanos , Masculino , Países Baixos , Ovinos , Resultado do Tratamento
13.
Europace ; 18(4): 479-91, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26041870

RESUMO

An increasing number of patients with implantable cardiac rhythm devices undergo radiotherapy (RT) for cancer and are thereby exposed to the risk of device failure. Current safety recommendations seem to have limitations by not accounting for the risk of pacemakers and implantable cardioverter defibrillators malfunctioning at low radiation doses. Besides scant knowledge about optimal safety measures, only little is known about the exact prevalence of patients with devices undergoing RT. In this review, we provide a short overview of the principles of RT and present the current evidence on the predictors and mechanisms of device malfunctions during RT. We also summarize practical recommendations from recent publications and from the industry. Strongly associated with beam energy of photon RT, device malfunctions occur at ∼3% of RT courses, posing a substantial issue in clinical practice. Malfunctions described in the literature typically consist of transient software disturbances and only seldom manifest as a permanent damage of the device. Through close cooperation between cardiologists and oncologists, a tailored individualized approach might be necessary in this patient group in waiting time for updated international guidelines in the field.


Assuntos
Estimulação Cardíaca Artificial , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Marca-Passo Artificial , Falha de Prótese , Radioterapia/efeitos adversos , Estimulação Cardíaca Artificial/normas , Desfibriladores Implantáveis/normas , Cardioversão Elétrica/normas , Segurança de Equipamentos , Humanos , Marca-Passo Artificial/normas , Segurança do Paciente , Guias de Prática Clínica como Assunto , Desenho de Prótese , Radioterapia/normas , Dosagem Radioterapêutica , Medição de Risco , Fatores de Risco
15.
J Cardiovasc Electrophysiol ; 26(3): 322-8, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25367066

RESUMO

INTRODUCTION: In this in vivo ovine study, we describe the course of pacing and sensing parameters during follow-up as well as the gross and histopathological features at the implant site of the recently described leadless cardiac pacemaker (LCP). METHODS AND RESULTS: All sheep underwent LCP implantation in the right ventricular (RV) apex. Serial pacing/sensing thresholds were assessed. In the first cohort, 11 animals were followed up for a period of 3 months, followed by necropsy. In the second cohort, 7 additional sheep were followed for a period of up to 18 months. Mean pacing and sensing thresholds in the 3-month cohort were 1.0 ± 0.5 V and 9.0 ± 3.7 mV at implant, and 0.7 ± 0.2 V and 8.1 ± 3.9 mV at 90 days, respectively. At necropsy at 3 months, all devices were securely implanted at the RV apex without extrusion of helix beyond the RV wall. Besides endocardial reactive changes in the RV apex surrounding the distal portion of the LCP, there were no other grossly visible abnormalities. In the second cohort (7 sheep), mean pacing and sensing thresholds were 1.0 ± 0.5 V and 9.9 ± 3.8 mV at implant, and 0.86 ± 0.4 V and 4.25 ± 1 mV, respectively, at 18 months of follow-up. CONCLUSION: We demonstrate that after implantation of the LCP, pacing/sensing parameters remain adequate up to 18 months in follow-up. In addition, pathological changes at the implant site and within the RV are limited in severity at 90 days, supporting the efficacy and safety of this novel approach to pacing.


Assuntos
Desfibriladores Implantáveis , Desenho de Equipamento/instrumentação , Modelos Animais , Marca-Passo Artificial , Animais , Desfibriladores Implantáveis/normas , Desenho de Equipamento/normas , Estudos de Viabilidade , Marca-Passo Artificial/normas , Ovinos , Resultado do Tratamento
16.
Anesthesiology ; 123(5): 1024-32, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26352380

RESUMO

BACKGROUND: Management of cardiovascular implantable electronic devices (CIEDs), including pacemakers and implantable cardioverter defibrillators, for surgical procedures is challenging due to the increasing number of patients with CIEDs and limited availability of trained providers. At the authors' institution, a small group of anesthesiologists were trained to interrogate CIEDs, devise a management plan, and perform preoperative and postoperative programming and device testing whenever necessary. METHODS: Patients undergoing surgery between October 1, 2009 and June 30, 2013 at the University of Washington Medical Center were included in a retrospective chart review to determine the number of devices actively managed by the Electrophysiology/Cardiology Service (EPCS) versus the Anesthesiology Device Service (ADS), changes in workload over time, surgical case delays due to device management, and errors and problems encountered in device programming. RESULTS: The EPCS managed 254 CIEDs, the ADS managed 548, and 227 by neither service. Over time, the ADS providers managed an increasing percentage of devices with decreasing supervision from the EPCS. Only two CIEDs managed by the ADS required immediate assistance from the EPCS. Patients who were unstable postoperatively were referred to the EPCS. Although numerous issues in programming were encountered, primarily when restoring demand pacing after programming asynchronous pacing for surgery, no patient harm resulted from ADS or EPCS management of CIEDs. CONCLUSIONS: An ADS can provide safe CIED management for surgery, but it requires specialized provider training and strong support from the EPCS. Due to the complexity of CIED management, an ADS will likely only be feasible in high-volume settings.


Assuntos
Anestesiologia/métodos , Desfibriladores Implantáveis , Serviços de Saúde , Marca-Passo Artificial , Assistência Perioperatória/métodos , Médicos , Anestesiologia/educação , Desfibriladores Implantáveis/normas , Gerenciamento Clínico , Feminino , Serviços de Saúde/normas , Humanos , Masculino , Marca-Passo Artificial/normas , Assistência Perioperatória/normas , Médicos/normas , Estudos Retrospectivos
17.
Europace ; 17(5): 787-93, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25733549

RESUMO

AIMS: Several studies demonstrated an inverse relationship between cardioverter-defibrillator implantation volume and complication rates, suggesting better outcomes for higher volume centres. However, the association of institutional procedural volume with patient outcomes for permanent pacemaker (PPM) implantation remains less known, especially in decentralized implantation systems. METHODS AND RESULTS: We performed retrospective examination of data on patients undergoing PPM from the German obligatory quality assurance programme (2007-12) to evaluate the relationship of hospital PPM volume (categorized into quintiles of their mean annual volume) with risk-adjusted in-hospital surgical complications (composite of pneumothorax, haemothorax, pericardial effusion, or pocket haematoma, all requiring intervention, or device infection) and pacemaker lead dislocation. Overall 430 416 PPM implantations were documented in 1226 hospitals. Systems included dual (72.8%) and single (25.8%) chamber PPM and cardiac resynchronization therapy (CRT) devices (1.1%). Complications included surgical (0.92%), and ventricular (0.99%), and atrial (1.22%) lead dislocation. Despite an increase in relatively complex procedures (dual chamber, CRT), there was a significant decrease in the procedural and fluoroscopy times and complications from lowest to highest implantation volume quintiles (P for trend <0.0001). The greatest difference was observed between the lowest (1-50 implantations/year-reference group) and the second-lowest (51-90 implantations/year) quintile: surgical complications [odds ratio (OR) 0.69; confidence interval (CI) 0.60-0.78], atrial lead dislocations (OR 0.69; CI 0.59-0.80), and ventricular lead dislocations (OR 0.73; CI 0.63-0.84). CONCLUSIONS: Hospital annual PPM volume was directly related to indication-based implantation of relatively more complex PPM and yet inversely with procedural times and rates of early surgical complications and lead dislocations. Thus, our data suggest better performance and lower complications with increasing procedural volume.


Assuntos
Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/normas , Hospitais com Alto Volume de Atendimentos/normas , Hospitais com Baixo Volume de Atendimentos/normas , Avaliação de Processos e Resultados em Cuidados de Saúde/normas , Marca-Passo Artificial/efeitos adversos , Marca-Passo Artificial/normas , Garantia da Qualidade dos Cuidados de Saúde/normas , Indicadores de Qualidade em Assistência à Saúde/normas , Idoso , Idoso de 80 Anos ou mais , Distribuição de Qui-Quadrado , Feminino , Alemanha , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Melhoria de Qualidade/normas , Sistema de Registros , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
18.
Neurol Neurochir Pol ; 49(1): 16-23, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25666768

RESUMO

UNLABELLED: Between September 2009 and May 2014 the classification of 36 patients with cardiac implantable electronic devices (CIEDs) in terms of the feasibility of MRI scanning due to strong clinical indications was carried out. Finally MRI examinations were performed in 20 patients, of whom 27 studies were conducted and a total number of 35 anatomical regions were scanned. Neurological, neurosurgical and neuro-oncology indications for MRI were reported in 19 patients (95%) in whom 26 MRI studies (96.3%) were performed, and 34 anatomical regions (97.1%) were scanned. One patient had indications for MRI in the field of cardiology. Medical information obtained from 27 MRI studies allowed decisions to be made regarding the treatment in all patients. After 8 studies (29.6%), patients were classified into 9 different neurosurgical procedures. In the case of the remaining 19 studies (70.4%), there were no indications for surgical treatment and the decisions to implement conservative treatment were made. There were no complications related to the implanted CIEDs observed: neither immediate nor in the follow-up.


Assuntos
Tomada de Decisões , Desfibriladores Implantáveis/normas , Imageamento por Ressonância Magnética/normas , Doenças do Sistema Nervoso/diagnóstico , Marca-Passo Artificial/normas , Guias de Prática Clínica como Assunto/normas , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Imageamento por Ressonância Magnética/efeitos adversos , Masculino , Pessoa de Meia-Idade , Doenças do Sistema Nervoso/cirurgia
19.
Europace ; 21(1): 7-8, 2019 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-29905786
SELEÇÃO DE REFERÊNCIAS