Your browser doesn't support javascript.
loading
¿La espectroscopia de infrarrojo cercano (NIRS) podría ser útil en el monitoreo hemodinámico del paciente critico pediátrico? / Near infrared spectroscopy (NIRS) can be useful in the hemodynamic monitoring of the pediatric critical patient?
Puentes López, Sindy Paola; Zárate Vergara, Andrea Carolina; Tirado Pérez, Irina Suley.
Afiliação
  • Puentes López, Sindy Paola; Universidad de Sucre. sincelejo. CO
  • Zárate Vergara, Andrea Carolina; Universidad de Sucre. sincelejo. CO
  • Tirado Pérez, Irina Suley; Universidad de Sucre. Sincelejo. CO
Biociencias ; 15(1): 73-78, jun.2020.
Article em Es | COLNAL, LILACS | ID: biblio-1122956
Biblioteca responsável: CO69.3
RESUMEN

Introducción:

La oximetría cerebral no invasiva utiliza la tecnología NIRS ("near infrared spectroscopy") para medir la saturación de oxígeno en una pequeña región de los vasos cerebrales corticales. Refleja el 75% volumen de oxigenación cerebral venosa y el 25% volumen de oxigenación cerebral arterial.

Objetivo:

Hacer una descripción breve sobre oximetría cerebral no invasiva mediante la tecnología NIRS ("near infrared spectroscopy"). Aunque esta técnica se describió hace más de 25 años, su uso es cada vez más frecuente siendo un fenómeno reciente.

Comentarios:

La saturación regional cerebral de oxígeno (rSO2c), al igual que la saturación pulsátil arterial periférica de oxígeno, se mide por espectrometría. Se basa en el hecho de que la hemoglobina oxigenada absorbe menos luz roja y más luz infrarroja que la hemoglobina. Es un método sencillo para identificar el límite inferior de la autorregulación, el punto por debajo del cual el flujo sanguíneo cerebral y la oxigenación tisular se hacen dependientes de la presión.

Conclusiones:

Los valores obtenidos de rSO2c representan el estado de oxigenación de los cromóforos del lecho vascular cerebral del compartimento venoso. Los cambios en la oximetría cerebral dependen del balance entre aporte y consumo de oxígeno.
ABSTRACT

Introduction:

Non-invasive cerebral oximetry uses NIRS ("near infrared spectroscopy") technology to measure oxygen saturation in a small region of cortical cerebral vessels. It reflects 75% volume of venous cerebral oxygenation and 25% volume of arterial cerebral oxygenation.

Objective:

To make a brief description about non-invasive cerebral oximetry using NIRS technology ("near infrared spectroscopy"). Although this technique was described more than 25 years ago, its use is increasingly frequent being a recent phenomenon.

Comments:

Regional cerebral oxygen saturation (rSO2c), like peripheral arterial pulsatile oxygen saturation, is measured by spectrometry. It is based on the fact that oxygenated hemoglobin absorbs less red light and more infrared light than hemoglobin. It is a simple method to identify the lower limit of self-regulation, the point below which cerebral blood flow and tissue oxygenation become pressure dependent.

Conclusions:

The values ​​obtained from rSO2c represent the oxygenation state of the chromophores of the cerebral vascular bed of the venous compartment. Changes in cerebral oximetry depend on the balance between oxygen intake and consumption.