Estudio comparativo de técnicas confirmatorias de anticuerpos frente VIH-1/2: Geeniusversus INNO-LIA / Comparative study of HIV-1/2 antibody confirmatory assay: Geenius versus INNO-LIA
Artigo
em Espanhol
| IBECS (Espanha) | ID: ibc-159558
Introducción. El objetivo del estudio es comparar dos ensayos confirmatorios de anticuerposfrente a la infección por VIH-1/2. Material y métodos. Estudio prospectivo (1/1/2015- 31/12/2015) en el que se incluyeron muestras de suero con resultados repetidamente positivos en la técnica de cribado Antigen-antibody assay HIV-1/2 (Architect, Abbott). En los sueros correspondientes a nuevos diagnósticos se utilizaron las técnicas confirmatorias Geenius HIV-1/2 assay (Bio-Rad) e INNO-LIA HIV-1/2 score line-immunoassay (Innogenetics®). La carga viralVIH-1 (Cobas® AmpliPrep/HIV, Roche) se realizó en casos discordantes e indeterminados. Resultados. Se incluyeron 85 muestras. Los resultados de ambas técnicas confirmatorias fueron concordantes en 80/85 muestras 53 VIH-1, 1 VIH-2, 25 negativos y 1 indeterminado. El coeficiente de concordancia Kappa de Cohen fue muy elevado (0,878). Conclusión. La concordancia entre las dos técnicas evaluadas es muy elevada. El procedimiento para realizar Geenius es rápido y sencillo. Geenius es una técnica alternativa, útil, a incluir en los algoritmos diagnósticos de infección por VIH-1/2 (AU)
Introduction. The aim of the study is to compare two confirmatory tests for HIV-1/2 infection. Material and methods. A prospective study was carried out between 01/01/2015 and 12/31/2015. Serum samples with repeatedly positive results in the Antibody- Antigen-HIV-1/2 (Architect, Abbott) screening assay were included. The serum samples corresponding to new diagnosed cases were selected and were used to compare the two confirmatory assays Geenius HIV-1/2 (Bio-Rad) and INNO-LIA HIV-1/2 score line-immunoassay (Innogenetics ®). The HIV-1viral load (Cobas® AmpliPrepHIV, Roche) was performed in discordant or indeterminate cases. Results. Eight five samples were included. The results of both confirmatory assays were concordant in 80/85 samples 53 HIV-1, 1 HIV-2, 25 negative and one indeterminate. Cohens Kappa concordance coefficient between Geenius and INNOLIA techniques was very high (0.878). Conclusion. The concordance between the two assays is high. The procedure for Geenius is simple and fast. Geenius is a good alternative to include in the HIV-1/2 diagnostic algorithm (AU)