Your browser doesn't support javascript.
loading
(99)mTc-tetrofosmin SPET in the detection of both primary breast cancer and axillary lymph node metastasis.
Spanu, A; Dettori, G; Nuvoli, S; Porcu, A; Falchi, A; Cottu, P; Solinas, M E; Scanu, A M; Chessa, F; Madeddu, G.
Afiliação
  • Spanu A; Department of Nuclear Medicine, University of Sassari, Viale San Pietro, 8, 07100 Sassari, Italy.
Eur J Nucl Med ; 28(12): 1781-94, 2001 Dec.
Article em En | MEDLINE | ID: mdl-11734916
The aim of this study was to evaluate the usefulness of (99m)Tc-tetrofosmin single-photon emission tomography (SPET) in the detection of both primary breast cancer and axillary lymph node metastasis. We studied 192 consecutive patients in whom primary breast cancer was suspected on the basis of mammography and/or physical examination. After intravenous injection of 740 MBq (99m)Tc-tetrofosmin, both planar and SPET scintimammography was performed in all patients using a rectangular dual-head gamma camera equipped with low-energy, high-resolution, parallel-hole collimators. In 175 patients with breast cancer at histology, the per-lesion overall sensitivity of SPET and planar imaging for the detection of breast cancer was 95.8% and 75.9% (P<0.0005), respectively. The sensitivity of SPET and planar imaging was, respectively, 96.5% and 79.5% in palpable (P<0.0005) and 90% and 45% in non-palpable lesions (P<0.01). With regard to lesion size, the sensitivity of SPET and planar imaging was, respectively, 90.5% and 45.2% in lesions < or =10 mm ( P<0.0005), 95.3% and 81.4% in lesions of 11-20 mm (P<0.005), 100% and 84.6% in lesions of 21-30 mm (P<0.05) and 100% and 95.8% in lesions >30 mm (P>0.05). In the remaining 17 patients with benign mammary lesions at histology, per-lesion overall specificity of SPET and planar imaging was 76.2% and 85.7% (P>0.05), respectively. Neither SPET nor planar imaging showed false-positive results in non-palpable lesions or in those < or =10 mm. In 173 breast cancer patients submitted to axillary lymph node dissection (ALND), per-axilla overall sensitivity of SPET and planar imaging in the detection of axillary lymph node metastasis was 93% and 52.3% ( P<0.0005), respectively. The sensitivity of SPET and planar imaging was, respectively, 100% and 82.6% in palpable nodes (P>0.05), 90.5% and 41.3% in non-palpable nodes (P<0.0005), 92.8% and 35.7% in the presence of < or =3 nodes ( P<0.0005) and 93.2% and 68.2% in the presence of >3 nodes (P<0.005). The specificity of SPET and planar imaging was 91% and 100% (P<0.05), respectively. (99m)Tc-tetrofosmin SPET appears to be a reliable method for the detection of both primary BC and axillary lymph node metastasis, and its diagnostic accuracy exceeds that of (99m)Tc-tetrofosmin planar scintimammography. The use of SPET is particularly important in the identification of small non-palpable primary carcinomas and metastatic axillae with < or =3 non-palpable lymph nodes. More extensive use of SPET appears warranted in the management of breast cancer patients.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Limite: Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2001 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Limite: Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2001 Tipo de documento: Article