Your browser doesn't support javascript.
loading
[Comparison of three neuro-tracing techniques for identification of the sciatic spinal nerve origin in mice]. / Comparación de tres técnicas de trazado retrógrado para la identificación del origen espinal del nervio ciático en ratón.
Velandia, Myriam L; Montoya, José V; Martínez, Marlén; Perdomo, Sandra; Castellanos, Jaime E.
Afiliação
  • Velandia ML; Laboratorio de Neurociencias, Instituto Nacional de Salud, Bogotá, D.C., Colombia.
Biomedica ; 22(4): 529-34, 2002 Dec.
Article em Es | MEDLINE | ID: mdl-12596451
To identify sensory and motor neurons associated with the sciatic nerve in adult mice, three methods for applying fluorescent tracers (Fluorogold and Dil) were investigated: direct application, intraneural injection and impregnation of a sectioned nerve in a silicone chamber. Most accurate localization of the neurons on the dorsal root ganglia and spinal cord was accomplished by introducing the proximal stump of a transected sciatic nerve into a silicone chamber, filled with tracers and then decalcifying the tissue. Fluorogold was an effective tracing agent, in contrast to Dil, which was not. In addition to associations with cephalic ganglia L4, L5 and L6, as seen in rats, contributory neurons to the sciatic nerve were located in other ganglia in the mouse. These findings show that the silicone chamber-tissue decalcification technique is a viable tool for obtaining comparative neuroanatomical information in the mouse model.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Animals Idioma: Es Ano de publicação: 2002 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Animals Idioma: Es Ano de publicação: 2002 Tipo de documento: Article