Your browser doesn't support javascript.
loading
[Electrical cardioversion and myocardial injury: evaluation by new cardiac injury markers]. / Cardioversão elétrica e lesão miocárdica: avaliação pelos novos marcadores de injúria cardíaca.
Santos, Elizabete Silva dos; Pereira, Marcos Paulo; Minuzzo, Luiz; Moreira, Dalmo A R; Ramos, Rui; Avezum, Alvaro; Timerman, Ari; Piegas, Leopoldo S.
Afiliação
  • Santos ES; Instituto Dante Pazzanese de Cardiologia, São Paulo, SP. elizabetssantos@cardiol.br
Arq Bras Cardiol ; 86(3): 191-7, 2006 Mar.
Article em Pt | MEDLINE | ID: mdl-16612445
OBJECTIVE: Evaluate, based on the evolution of new biochemical markers of cardiac damage, if electrical cardioversion (ECV) causes myocardial injury. METHODS: Seventy-six patients (P) submitted to elective ECV for atrial fibrillation or atrial flutter were evaluated. Creatine phosphokinase (CPK), CK-MB activity, CK-MB mass, myoglobin and cardiac troponin I (cTnI) were measured before, and 6 and 24 hours after ECV. RESULTS: ECV was successful in 58 P (76.3%). Cumulative energy (CE) was up to 350 joules (J) in 36 P, from 500 to 650 J in 20 P and from 900 to 960 J in 20 P; the mean energy delivered being 493 J (+/- 309). The levels of cTnI remained within normal limits in all 76 P. The increase of cumulative energy led to an elevation of CPK levels (> p value = 0.007), CK-MB activity (> p value = 0.002), CK-MB mass (> p value = 0.03), and myoglobin (> p value = 0.015). A positive correlation between the cumulative energy and CPK peaks was observed (r = 0.660; p < 0.001), CK-MB activity (r = 0.429; p < 0.0001), CK-MB mass (r = 0.265; p = 0.02), and myoglobin (r = 0.684; p < 0.0001), as well as between the number of shocks and the CPK peaks (r = 0.770; p < 0.001), CK-MB activity (r = 0.642; p < 0.0001), CK-MB mass (r = 0.430; p < 0.0001), and myoglobin (r = 0.745; p < 0.0001). CONCLUSION: ECV does not cause myocardial injury detectable by cTnI measurement. Elevations of CPK, CK-MB activity, CK-MB mass and myoglobin result from skeletal muscle injury and are positively correlated with the CE delivered or with the number of shocks.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Evaluation_studies Limite: Female / Humans / Male / Middle aged Idioma: Pt Ano de publicação: 2006 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Evaluation_studies Limite: Female / Humans / Male / Middle aged Idioma: Pt Ano de publicação: 2006 Tipo de documento: Article