Your browser doesn't support javascript.
loading
PGD for a complex chromosomal rearrangement by array comparative genomic hybridization.
Vanneste, E; Melotte, C; Voet, T; Robberecht, C; Debrock, S; Pexsters, A; Staessen, C; Tomassetti, C; Legius, E; D'Hooghe, T; Vermeesch, J R.
Afiliação
  • Vanneste E; Center for Human Genetics, UZ Gasthuisberg, 3000 Leuven, Belgium.
Hum Reprod ; 26(4): 941-9, 2011 Apr.
Article em En | MEDLINE | ID: mdl-21292638
ABSTRACT
Patients carrying a chromosomal rearrangement (CR) have an increased risk for chromosomally unbalanced conceptions. Preimplantation genetic diagnosis (PGD) may avoid the transfer of embryos carrying unbalanced rearrangements, therefore increasing the chance of pregnancy. Only 7-12 loci can be screened by fluorescence in situ hybridization whereas microarray technology can detect genome-wide imbalances at the single cell level. We performed PGD for a CR carrier with karyotype 46,XY,ins(3;2)(p23;q23q14.2),t(6;14)(p12.2;q13) using array comparative genomic hybridization. Selection of embryos for transfer was only based on copy number status of the chromosomes involved in both rearrangements. In two ICSI-PGD cycles, nine and seven embryos were analysed by array, leaving three and one embryo(s) suitable for transfer, respectively. The sensitivity and specificity of single cell arrays was 100 and 88.8%, respectively. In both cycles a single embryo was transferred, resulting in pregnancy following the second cycle. The embryo giving rise to the pregnancy was normal/balanced for the insertion and translocation but carried a trisomy 8 and nullisomy 9 in one of the two biopsied blastomeres. After 7 weeks of pregnancy the couple miscarried. Genetic analysis following hystero-embryoscopy showed a diploid (90%)/tetraploid (10%) mosaic chorion, while the gestational sac was empty. No chromosome 8 aneuploidy was detected in the chorion, while 8% of the cells carried a monosomy for chromosome 9. In summary, we demonstrate the feasibility and determine the accuracy of single cell array technology to test against transmission of the unbalanced meiotic products that can derive from CRs. Our findings also demonstrate that the genomic constitution of extra-embryonic tissue cannot necessarily be predicted from the copy number status of a single blastomere.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Adult / Female / Humans / Male / Pregnancy Idioma: En Ano de publicação: 2011 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Adult / Female / Humans / Male / Pregnancy Idioma: En Ano de publicação: 2011 Tipo de documento: Article