Automatic DGD and GVD compensation at 640 Gb/s based on scalar radio-frequency spectrum measurement.
Appl Opt
; 52(9): 1919-27, 2013 Mar 20.
Article
em En
| MEDLINE
| ID: mdl-23518737
We demonstrate what we believe to be the first real-time impairment-cancellation system for group-velocity dispersion (GVD) and differential group delay (DGD) for a 640 Gb/s single-channel signal. Simultaneous compensation of two independent parameters is demonstrated by feedback control of separate GVD and DGD compensators using an impairment monitor based on an integrated all-optical radio-frequency (RF) spectrum analyzer. We show that low-bandwidth measurement of only a single tone in the RF spectrum is sufficient for automatic compensation for multiple degrees of freedom using a multivariate optimization scheme.
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Idioma:
En
Ano de publicação:
2013
Tipo de documento:
Article