Your browser doesn't support javascript.
loading
Defibrillator implantations for primary prevention in the United States: Inappropriate care or inadequate documentation: Insights from the National Cardiovascular Data ICD Registry.
Kaiser, Daniel W; Tsai, Vivian; Heidenreich, Paul A; Goldstein, Mary K; Wang, Yongfei; Curtis, Jeptha; Turakhia, Mintu P.
Afiliação
  • Kaiser DW; Stanford University School of Medicine, Stanford, California.
  • Tsai V; Stanford University School of Medicine, Stanford, California.
  • Heidenreich PA; Stanford University School of Medicine, Stanford, California; VA Palo Alto Health Care System, Palo Alto, California.
  • Goldstein MK; Stanford University School of Medicine, Stanford, California; VA Palo Alto Health Care System, Palo Alto, California.
  • Wang Y; Yale University, New Haven, Connecticut.
  • Curtis J; Yale University, New Haven, Connecticut.
  • Turakhia MP; Stanford University School of Medicine, Stanford, California; VA Palo Alto Health Care System, Palo Alto, California. Electronic address: mintu@stanford.edu.
Heart Rhythm ; 12(10): 2086-93, 2015 Oct.
Article em En | MEDLINE | ID: mdl-25982720
ABSTRACT

BACKGROUND:

Prior studies have reported that more than 20% of implantable cardioverter-defibrillator (ICD) implantations in the United States do not adhere to trial-based criteria.

OBJECTIVE:

We sought to investigate the patient characteristics associated with not meeting the inclusion criteria of the clinical trials that have demonstrated the efficacy of primary prevention ICDs.

METHODS:

Using data from the National Cardiovascular Data Registry's ICD Registry, we identified patients who received ICDs for primary prevention from January 2006 to December 2008. We determined whether patients met the inclusion criteria of at least 1 of the 4 ICD primary prevention trials Multicenter Automatic Defibrillator Implantation Trial (MADIT), MADIT-II, Sudden Cardiac Death in Heart Failure Trial (SCD-HeFT), and the Multicenter Unsustained Tachycardia Trial (MUSTT).

RESULTS:

Among 150,264 patients, 86% met criteria for an ICD implantation based on trial data. The proportion of patients who did not meet trial-based criteria increased as age decreased. In multivariate analysis, the significant predictors for not meeting trial criteria included prior cardiac transplantation (odds ratio [OR] 2.1), pediatric electrophysiology operator (OR 2.0), and high-grade atrioventricular conduction disease (OR 1.4).

CONCLUSION:

Among National Cardiovascular Data Registry registrants receiving first-time ICDs for primary prevention, the majority met trial-based criteria. Multivariate analyses suggested that many patients who did not meet the trial-based criteria may have had clinical circumstances that warranted ICD implantation. These findings caution against the use of trial-based indications to determine site quality metrics that could penalize sites that care for younger patients. The planned incorporation of appropriate use criteria into the ICD registry may better characterize patient- and site-level quality and performance.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male / Middle aged País/Região como assunto: America do norte Idioma: En Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male / Middle aged País/Região como assunto: America do norte Idioma: En Ano de publicação: 2015 Tipo de documento: Article