Your browser doesn't support javascript.
loading
Ion pair liquid chromatography method for the determination of thiamine (vitamin B1) homeostasis.
Basiri, Babak; Sutton, James Michael; Hanberry, Bradley S; Zastre, Jason A; Bartlett, Michael G.
Afiliação
  • Basiri B; Department of Pharmaceutical and Biomedical Sciences, The University of Georgia College of Pharmacy, 250 W. Green Street, Athens, GA, 30602-2352, USA.
  • Sutton JM; Department of Pharmaceutical and Biomedical Sciences, The University of Georgia College of Pharmacy, 250 W. Green Street, Athens, GA, 30602-2352, USA.
  • Hanberry BS; Department of Pharmaceutical and Biomedical Sciences, The University of Georgia College of Pharmacy, 250 W. Green Street, Athens, GA, 30602-2352, USA.
  • Zastre JA; Department of Pharmaceutical and Biomedical Sciences, The University of Georgia College of Pharmacy, 250 W. Green Street, Athens, GA, 30602-2352, USA.
  • Bartlett MG; Department of Pharmaceutical and Biomedical Sciences, The University of Georgia College of Pharmacy, 250 W. Green Street, Athens, GA, 30602-2352, USA.
Biomed Chromatogr ; 30(1): 35-41, 2016 Jan.
Article em En | MEDLINE | ID: mdl-26120008
ABSTRACT
A new method for reversed phase HPLC determination of thiamine and its major in vivo phosphorylation products, thiamine monophosphate (TMP) and thiamine pyrophosphate (TPP), was developed using tetrabutylammonium hydroxide as the ion-pairing agent. The separation was performed on a Phenomenex Kinetex EVO C18 column with a gradient of a phosphate-buffered aqueous solution of the ion-pair reagent and methanol. The duty cycle for the assay was 13 min and pyrithiamine was successfully used as the internal standard for the first time in a thiamine HPLC measurement protocol. Detection of the fluorescence derivatives of the analytes as well as the IS allowed for lower detection limits in order to support biological applications in cell culture models. The linearity, sensitivity, specificity, accuracy and precision of the method were evaluated and met the requirements specified by the US Food and Drug Administration. The calibration curves proved to be linear and the method was validated over the range from 1.0-4000 nM for both cells and the media where complete recovery of the analytes was also achieved.