Your browser doesn't support javascript.
loading
Performance of a TthPrimPol-based whole genome amplification kit for copy number alteration detection using massively parallel sequencing.
Deleye, Lieselot; De Coninck, Dieter; Dheedene, Annelies; De Sutter, Petra; Menten, Björn; Deforce, Dieter; Van Nieuwerburgh, Filip.
Afiliação
  • Deleye L; Laboratory of Pharmaceutical Biotechnology, Ghent University, Ottergemsesteenweg 460, 9000 Ghent, Belgium.
  • De Coninck D; Laboratory of Pharmaceutical Biotechnology, Ghent University, Ottergemsesteenweg 460, 9000 Ghent, Belgium.
  • Dheedene A; Center for Medical Genetics, Ghent University, De Pintelaan 185, 9000 Ghent, Belgium.
  • De Sutter P; Department for Reproductive Medicine, Ghent University Hospital, De Pintelaan 185, 9000 Ghent, Belgium.
  • Menten B; Center for Medical Genetics, Ghent University, De Pintelaan 185, 9000 Ghent, Belgium.
  • Deforce D; Laboratory of Pharmaceutical Biotechnology, Ghent University, Ottergemsesteenweg 460, 9000 Ghent, Belgium.
  • Van Nieuwerburgh F; Laboratory of Pharmaceutical Biotechnology, Ghent University, Ottergemsesteenweg 460, 9000 Ghent, Belgium.
Sci Rep ; 6: 31825, 2016 08 22.
Article em En | MEDLINE | ID: mdl-27546482
ABSTRACT
Starting from only a few cells, current whole genome amplification (WGA) methods provide enough DNA to perform massively parallel sequencing (MPS). Unfortunately, all current WGA methods introduce representation bias which limits detection of copy number aberrations (CNAs) smaller than 3 Mb. A recent WGA method, called TruePrime single cell WGA, uses a recently discovered DNA primase, TthPrimPol, instead of artificial primers to initiate DNA amplification. This method could lead to a lower representation bias, and consequently to a better detection of CNAs. The enzyme requires no complementarity and thus should generate random primers, equally distributed across the genome. The performance of TruePrime WGA was assessed for aneuploidy screening and CNA analysis after MPS, starting from 1, 3 or 5 cells. Although the method looks promising, the single cell TruePrime WGA kit v1 is not suited for high resolution CNA detection after MPS because too much representation bias is introduced.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Limite: Female / Humans Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Limite: Female / Humans Idioma: En Ano de publicação: 2016 Tipo de documento: Article