Your browser doesn't support javascript.
loading
Determination of mercury in hair: Comparison between gold amalgamation-atomic absorption spectrometry and mass spectrometry.
Domanico, Francesco; Forte, Giovanni; Majorani, Costanza; Senofonte, Oreste; Petrucci, Francesco; Pezzi, Vincenzo; Alimonti, Alessandro.
Afiliação
  • Domanico F; University of Calabria, Arcavacata di Rende (CS), Italy.
  • Forte G; Italian National Institute for Health, Rome, Italy.
  • Majorani C; Italian National Institute for Health, Rome, Italy.
  • Senofonte O; Italian National Institute for Health, Rome, Italy. Electronic address: oreste.senofonte@iss.it.
  • Petrucci F; Italian National Institute for Health, Rome, Italy.
  • Pezzi V; University of Calabria, Arcavacata di Rende (CS), Italy.
  • Alimonti A; Italian National Institute for Health, Rome, Italy.
J Trace Elem Med Biol ; 43: 3-8, 2017 Sep.
Article em En | MEDLINE | ID: mdl-27769745
ABSTRACT
Mercury is a heavy metal that causes serious health problems in exposed subjects. The most toxic form, i.e., methylmercury (MeHg), is mostly excreted through human hair. Numerous analytical methods are available for total Hg analysis in human hair, including cold vapour atomic fluorescence spectrometry (CV-AFS), inductively coupled plasma mass spectrometry (ICP-MS) and thermal decomposition amalgamation atomic absorption spectrometry (TDA-AAS). The aim of the study was to compare the TDA-AAS with the ICP-MS in the Hg quantification in human hair. After the washing procedure to minimize the external contamination, from each hair sample two aliquots were taken; the first was used for direct analysis of Hg by TDA-AAS and the second was digested for Hg determination by the ICP-MS. Results indicated that the two data sets were fully comparable (median; TDA-AAS, 475ngg-1; ICP-MS, 437ngg-1) and were not statistically different (Mann-Whitney test; p=0.44). The two techniques presented results with a good coefficient of correlation (r=0.94) despite different operative ranges and method limits. Both techniques satisfied internal performance requirements and the parameters for method validation resulting sensitive, precise and reliable. Finally, the use of the TDA-AAS can be considered instead of the ICP-MS in hair analysis in order to reduce sample manipulation with minor risk of contamination, less time consuming due to the absence of the digestion step and cheaper analyses.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Limite: Humans Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Limite: Humans Idioma: En Ano de publicação: 2017 Tipo de documento: Article