Your browser doesn't support javascript.
loading
Antimicrobial efficacy and mechanical properties of BAC-modified hard and soft denture liners.
Altinci, Pinar; Mutluay, Murat; Söderling, Eva; Tezvergil-Mutluay, Arzu.
Afiliação
  • Altinci P; Finnish Doctoral Program in Oral Sciences, Turku, Finland. paltinci@hotmail.com.
  • Mutluay M; Department of Restorative Dentistry and Cariology, Institute of Dentistry, University of Turku, Lemminkaisenkatu 2, 20520, Turku, Finland. paltinci@hotmail.com.
  • Söderling E; Department of Restorative Dentistry and Cariology, Institute of Dentistry, University of Turku, Lemminkaisenkatu 2, 20520, Turku, Finland.
  • Tezvergil-Mutluay A; TYKS University Hospital, University of Turku, Turku, Finland.
Odontology ; 106(1): 83-89, 2018 Jan.
Article em En | MEDLINE | ID: mdl-28321584
This study investigated the antimicrobial efficacy and mechanical strength of hard and soft denture liners modified with benzalkonium chloride (BAC). The specimens (1 mm thickness, 8 mm diameter) were prepared by mixing 0.5, 1, 2 and 5 wt% BAC with soft (Sofreliner Medium, Tokuyama) and hard (Rebase II, Tokuyama) denture liners (n = 5/group). BAC was not added to the controls. Candida albicans ATCC 28366 (A 550 = 0.5) and Streptococcus mutans Ingbritt suspensions (A 550 = 0.35) were pipetted onto the specimens, and incubated for 4 h. The viable cells were collected, and determined by plate-culturing (CFU). The tests were repeated after the specimens were soaked in distilled water for 7 days. The mechanical strengths were evaluated by tear and 4-point flexural strength tests for soft and hard liners, respectively. The data were analyzed with ANOVA and Tukey's HSD tests at p = 0.05. C. albicans viability was lost in all groups of BAC-modified soft liners (p < 0.001), and S. mutans viability was reduced (p < 0.01), except of soaked BAC 0.5 wt% group (p > 0.05). For the hard liner, BAC 5 wt% killed the C. albicans and S. mutans cells both before and after soaked in water (p < 0.001). BAC 2 wt% showed comparable tear strength with the soft liner control (p > 0.05). BAC did not reduce the flexural strength of the hard liner (p > 0.05), except of BAC 5 wt% group (p < 0.01). BAC can be a promising agent reducing the C. albicans and S. mutans viability on the soft and hard denture liner surfaces.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2018 Tipo de documento: Article