Your browser doesn't support javascript.
loading
Clinical Utility of Fetal Short-Lag Spatial Coherence Imaging.
Long, Will; Hyun, Dongwoon; Choudhury, Kingshuk Roy; Bradway, David; McNally, Patricia; Boyd, Brita; Ellestad, Sarah; Trahey, Gregg E.
Afiliação
  • Long W; Department of Biomedical Engineering, Duke University, Durham, North Carolina, USA. Electronic address: willie.long@duke.edu.
  • Hyun D; Department of Biomedical Engineering, Duke University, Durham, North Carolina, USA; Department of Radiology, Stanford University, Stanford, California, USA.
  • Choudhury KR; Department of Radiology, Duke University Medical Center, Durham, North Carolina, USA.
  • Bradway D; Department of Biomedical Engineering, Duke University, Durham, North Carolina, USA.
  • McNally P; Department of Women's and Children's Services, Duke University Hospital, Durham, North Carolina, USA.
  • Boyd B; Division of Maternal-Fetal Medicine, Duke University Medical Center, Durham, North Carolina, USA.
  • Ellestad S; Division of Maternal-Fetal Medicine, Duke University Medical Center, Durham, North Carolina, USA.
  • Trahey GE; Department of Biomedical Engineering, Duke University, Durham, North Carolina, USA; Department of Radiology, Duke University Medical Center, Durham, North Carolina, USA.
Ultrasound Med Biol ; 44(4): 794-806, 2018 04.
Article em En | MEDLINE | ID: mdl-29336851
ABSTRACT
In this study, we evaluate the clinical utility of fetal short-lag spatial coherence (SLSC) imaging. Previous work has documented significant improvements in image quality with fetal SLSC imaging as quantified by measurements of contrast and contrast-to-noise ratio (CNR). The objective of this study was to examine whether this improved technical efficacy is indicative of the clinical utility of SLSC imaging. Eighteen healthy volunteers in their first and second trimesters of pregnancy were scanned using a modified Siemens SC2000 clinical scanner. Raw channel data were acquired for routinely examined fetal organs and used to generate fully matched raw and post-processed harmonic B-mode and SLSC image sequences, which were subsequently optimized for dynamic range and other imaging parameters by a blinded sonographer. Optimized videos were reviewed in matched B-mode and SLSC pairs by three blinded clinicians who scored each video based on overall quality, target conspicuity and border definition. SLSC imaging was highly favored over conventional imaging with SLSC scoring equal to (28.2 ± 10.5%) or higher than (63.9 ± 12.9%) B-mode for video pairs across all examined structures and processing conditions. Multivariate modeling revealed that SLSC imaging is a significant predictor of improved image quality with p ≤ 0.002. Expert-user scores for image quality support the application of SLSC in fetal ultrasound imaging.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Adult / Female / Humans / Pregnancy Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Adult / Female / Humans / Pregnancy Idioma: En Ano de publicação: 2018 Tipo de documento: Article