Your browser doesn't support javascript.
loading
OMNY-A tOMography Nano crYo stage.
Holler, M; Raabe, J; Diaz, A; Guizar-Sicairos, M; Wepf, R; Odstrcil, M; Shaik, F R; Panneels, V; Menzel, A; Sarafimov, B; Maag, S; Wang, X; Thominet, V; Walther, H; Lachat, T; Vitins, M; Bunk, O.
Afiliação
  • Holler M; Paul Scherrer Institut, 5232 Villigen PSI, Switzerland.
  • Raabe J; Paul Scherrer Institut, 5232 Villigen PSI, Switzerland.
  • Diaz A; Paul Scherrer Institut, 5232 Villigen PSI, Switzerland.
  • Guizar-Sicairos M; Paul Scherrer Institut, 5232 Villigen PSI, Switzerland.
  • Wepf R; Scientific Center for Optical and Electron Microscopy ScopeM, ETH Zurich, Zurich, Switzerland.
  • Odstrcil M; Paul Scherrer Institut, 5232 Villigen PSI, Switzerland.
  • Shaik FR; Paul Scherrer Institut, 5232 Villigen PSI, Switzerland.
  • Panneels V; Paul Scherrer Institut, 5232 Villigen PSI, Switzerland.
  • Menzel A; Paul Scherrer Institut, 5232 Villigen PSI, Switzerland.
  • Sarafimov B; Paul Scherrer Institut, 5232 Villigen PSI, Switzerland.
  • Maag S; Paul Scherrer Institut, 5232 Villigen PSI, Switzerland.
  • Wang X; Paul Scherrer Institut, 5232 Villigen PSI, Switzerland.
  • Thominet V; Paul Scherrer Institut, 5232 Villigen PSI, Switzerland.
  • Walther H; Paul Scherrer Institut, 5232 Villigen PSI, Switzerland.
  • Lachat T; EnDes Engineering Partner AG, 4703 Kestenholz, Switzerland.
  • Vitins M; Paul Scherrer Institut, 5232 Villigen PSI, Switzerland.
  • Bunk O; Paul Scherrer Institut, 5232 Villigen PSI, Switzerland.
Rev Sci Instrum ; 89(4): 043706, 2018 Apr.
Article em En | MEDLINE | ID: mdl-29716370
For many scientific questions gaining three-dimensional insight into a specimen can provide valuable information. We here present an instrument called "tOMography Nano crYo (OMNY)," dedicated to high resolution 3D scanning x-ray microscopy at cryogenic conditions via hard X-ray ptychography. Ptychography is a lens-less imaging method requiring accurate sample positioning. In OMNY, this in achieved via dedicated laser interferometry and closed-loop position control reaching sub-10 nm positioning accuracy. Cryogenic sample conditions are maintained via conductive cooling. 90 K can be reached when using liquid nitrogen as coolant, and 10 K is possible with liquid helium. A cryogenic sample-change mechanism permits measurements of cryogenically fixed specimens. We compare images obtained with OMNY with older measurements performed using a nitrogen gas cryo-jet of stained, epoxy-embedded retina tissue and of frozen-hydrated Chlamydomonas cells.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Limite: Animals Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Limite: Animals Idioma: En Ano de publicação: 2018 Tipo de documento: Article