Your browser doesn't support javascript.
loading
On the Development of Health-Based Ventilation Guidelines: Principles and Framework.
Carrer, Paolo; de Oliveira Fernandes, Eduardo; Santos, Hugo; Hänninen, Otto; Kephalopoulos, Stylianos; Wargocki, Pawel.
Afiliação
  • Carrer P; Occupational and Environmental Health, Department of Biomedical and Clinical Sciences "L. Sacco" University of Milan, IT-20157 Milan, Italy. paolo.carrer@unimi.it.
  • de Oliveira Fernandes E; University of Porto, 4200-465 Porto, Portugal. eof@fe.up.pt.
  • Santos H; INEGI-Institute of Science and Innovation in Mechanical and Industrial Engineering, 4200-465 Porto, Portugal. hsantos@inegi.up.pt.
  • Hänninen O; National Institute for Health and Welfare, FI-70701 Kuopio, Finland. otto.hanninen@thl.fi.
  • Kephalopoulos S; European Commission, Joint Research Centre, Directorate for Health, Consumers and Reference Materials, 20127 Ispra, Italy. stylianos.kephalopoulos@ec.europa.eu.
  • Wargocki P; International Centre for Indoor Environment and Energy, Department of Civil Engineering, Technical University of Denmark, DK-2800 Kongens Lyngby, Denmark. paw@byg.dtu.dk.
Article em En | MEDLINE | ID: mdl-29958470
ABSTRACT
This paper summarizes the results of HealthVent project. It had an aim to develop health-based ventilation guidelines and through this process contribute to advance indoor air quality (IAQ) policies and guidelines. A framework that allows determining ventilation requirements in public and residential buildings based on the health requirements is proposed. The framework is based on three principles 1. Criteria for permissible concentrations of specific air pollutants set by health authorities have to be respected; 2. Ventilation must be preceded by source control strategies that have been duly adopted to improve IAQ; 3. Base ventilation must always be secured to remove occupant emissions (bio-effluents). The air quality guidelines defined by the World Health Organization (WHO) outside air are used as the reference for determining permissible levels of the indoor air pollutants based on the principle that there is only one air. It is proposed that base ventilation should be set at 4 L/s per person; higher rates are to be used only if WHO guidelines are not followed. Implementation of the framework requires technical guidelines, directives and other legislation. Studies are also needed to examine the effectiveness of the approach and to validate its use. It is estimated that implementing the framework would bring considerable reduction in the burden of disease associated with inadequate IAQ.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Guideline Limite: Humans Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Guideline Limite: Humans Idioma: En Ano de publicação: 2018 Tipo de documento: Article