Your browser doesn't support javascript.
loading
Benzoxazine-based fluorescent probes with different auxochrome groups for cysteine detection.
Yang, Xiu-Zhi; Wei, Xue-Rui; Sun, Ru; Xu, Yu-Jie; Ge, Jian-Feng.
Afiliação
  • Yang XZ; College of Chemistry, Chemical Engineering and Material Science, Soochow University, 199 Ren'Ai Road, Suzhou, 215123, China.
  • Wei XR; State Key Laboratory of Radiation Medicine and Protection, School of Radiation Medicine and Protection and Collaborative Innovation Center of Radiation Medicine of Jiangsu Higher Education Institutions, Soochow University, Suzhou, 215123, China.
  • Sun R; College of Chemistry, Chemical Engineering and Material Science, Soochow University, 199 Ren'Ai Road, Suzhou, 215123, China. Electronic address: sunru924@hotmail.com.
  • Xu YJ; State Key Laboratory of Radiation Medicine and Protection, School of Radiation Medicine and Protection and Collaborative Innovation Center of Radiation Medicine of Jiangsu Higher Education Institutions, Soochow University, Suzhou, 215123, China.
  • Ge JF; College of Chemistry, Chemical Engineering and Material Science, Soochow University, 199 Ren'Ai Road, Suzhou, 215123, China; Jiangsu Key Laboratory of Medical Optics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, 215163, China. Electronic address: ge
Spectrochim Acta A Mol Biomol Spectrosc ; 226: 117582, 2020 Feb 05.
Article em En | MEDLINE | ID: mdl-31629978
ABSTRACT
Three 5H-benzo[a]phenoxazin-5-one-based (benzoresorufin and nile-red) Cysteine (Cys) detection probes have been comparatively designed and synthesized in this paper. The optical experiments exhibit probe 1b with a crotonoyl group has no response toward Cys; while probes 1a and 1c have the same reaction site (acryloyl group), their optical responses to Cys are quite different. The benzoresorufin-based-probe 1a shows a turn-on fluorescence response (118-fold) to Cys at 631 nm and affords a very low detection limit (DL = 19.8 nM). Compared with probe 1a, the nile-red-based probe 1c displays gradually diminishing fluorescence intensity with increased Cys concentration at 665 nm. And the notable different fluorescence response mechanisms of probes 1a and 1c toward Cys can be interpreted by HRMS and time-dependent density functional theorety (TDDFT) calculations. Furthermore, both of the two probes indicate high sensitivity and selectivity toward Cys over other similar structured amino acids including homocysteine (Hcy) and glutathione (GSH). Further cellular applications of the two probes have been successfully performed in HeLa cells.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Ano de publicação: 2020 Tipo de documento: Article