Your browser doesn't support javascript.
loading
Comprehensive online multicolumn two-dimensional liquid chromatography-diode array detection-mass spectrometry workflow as a framework for chromatographic screening and analysis of new drug substances.
Pickens, Chad J; Haidar Ahmad, Imad A; Makarov, Alexey A; Bennett, Raffeal; Mann, Benjamin F; Regalado, Erik L.
Afiliação
  • Pickens CJ; Analytical Research and Development, MRL, Merck & Co., Inc, Rahway, NJ, 07065, USA. chad.pickens@merck.com.
  • Haidar Ahmad IA; Analytical Research and Development, MRL, Merck & Co., Inc, Rahway, NJ, 07065, USA.
  • Makarov AA; Analytical Research and Development, MRL, Merck & Co., Inc, Rahway, NJ, 07065, USA.
  • Bennett R; Analytical Research and Development, MRL, Merck & Co., Inc, Rahway, NJ, 07065, USA.
  • Mann BF; Analytical Research and Development, MRL, Merck & Co., Inc, Rahway, NJ, 07065, USA.
  • Regalado EL; Analytical Research and Development, MRL, Merck & Co., Inc, Rahway, NJ, 07065, USA.
Anal Bioanal Chem ; 412(11): 2655-2663, 2020 Apr.
Article em En | MEDLINE | ID: mdl-32128644
The analysis of complex mixtures of closely related species is quickly becoming a bottleneck in the development of new drug substances, reflecting the ever-increasing complexity of both fundamental biology and the therapeutics used to treat disease. Two-dimensional liquid chromatography (2D-LC) is emerging as a powerful tool to achieve substantial improvements in peak capacity and selectivity. However, 2D-LC suffers from several limitations, including the lack of automated multicolumn setups capable of combining multiple columns in both dimensions. Herein, we report an investigation into the development and implementation of a customized online comprehensive multicolumn 2D-LC-DAD-MS setup for screening and method development purposes, as well as analysis of multicomponent biopharmaceutical mixtures. In this study, excellent chromatographic performance in terms of selectivity, peak shape, and reproducibility were achieved by combining reversed-phase (RP), strong cation exchange (SCX), strong anion exchange (SAX), and size exclusion chromatography (SEC) using sub-2-µm columns in the first dimension in conjunction with several 3.0 mm × 50 mm RP columns packed with sub-3-µm fully porous particles in the second dimension. Multiple combinations of separation modes coupled to UV and MS detection are applied to the LC × LC analysis of a protein standard mixture, intended to be representative of protein drug substances. The results reported in this study demonstrate that our automated online multicolumn 2D-LC-DAD-MS workflow can be a powerful tool for comprehensive chromatographic column screening that enables the semi-automated development of 2D-LC methods, offering the ability to streamline full visualization of sample composition for an unknown complex mixture while maximizing chromatographic orthogonality. Graphical Abstract.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies / Screening_studies Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies / Screening_studies Idioma: En Ano de publicação: 2020 Tipo de documento: Article