Your browser doesn't support javascript.
loading
Stimulus Response of TPE-TS@Eu/GMP ICPs: Toward Colorimetric Sensing of an Anthrax Biomarker with Double Ratiometric Fluorescence and Its Coffee Ring Test Kit for Point-of-Use Application.
Huang, Chunyu; Ma, Ruixue; Luo, Yuxin; Shi, Guoyue; Deng, Jingjing; Zhou, Tianshu.
Afiliação
  • Huang C; School of Ecological and Environmental Sciences, Shanghai Key Laboratory for Urban Ecological Process and Eco-Restoration, East China Normal University, 500 Dongchuan Road, Shanghai 200241, China.
  • Ma R; Institute of Eco-Chongming, 3663 Zhongshan Road, Shanghai 200062, China.
  • Luo Y; School of Ecological and Environmental Sciences, Shanghai Key Laboratory for Urban Ecological Process and Eco-Restoration, East China Normal University, 500 Dongchuan Road, Shanghai 200241, China.
  • Shi G; Institute of Eco-Chongming, 3663 Zhongshan Road, Shanghai 200062, China.
  • Deng J; School of Ecological and Environmental Sciences, Shanghai Key Laboratory for Urban Ecological Process and Eco-Restoration, East China Normal University, 500 Dongchuan Road, Shanghai 200241, China.
  • Zhou T; Institute of Eco-Chongming, 3663 Zhongshan Road, Shanghai 200062, China.
Anal Chem ; 92(19): 12934-12942, 2020 10 06.
Article em En | MEDLINE | ID: mdl-32854503
In this work, by fully exploring the stimulus response of infinite coordination polymer nanoparticles (ICPs) and by taking advantage of the particular optical properties of ICP guest tetra(4-sulfophenyl)ethene (TPE-TS) with adjustable monomer emission (ME) and aggregation-induced emission (AIE), we demonstrated a novel sensing mechanism for an anthrax biomarker dipicolinic acid (DPA) based on the competitive coordination interaction regulating the structure of TPE-TS@Eu/GMP ICPs. The double ratiometric fluorescence stemmed from triple response of TPE-TS@Eu/GMP ICPs without spectral cross-interference (ME and AIE from TPE-TS and sensitized emission from Eu/DPA) and a corresponding blue-to-red fluorescent color change, which not only benefited the direct detection of DPA with high sensitivity and selectivity, but also offered a great opportunity to realize real-time monitoring of DPA released by Bacillus subtilis spores. Furthermore, the coffee ring deposition patterns on a test paper were innovatively tuned by the quantity and morphology changes of TPE-TS@Eu/GMP ICPs during their stimulus response toward DPA, which could be exploited as expanded signal channels. By integrating a multichannel responsive coffee ring test kit with image recognition and processing application installed on smartphones, point-of-use analysis of DPA could be realized in a low-cost and high-throughput fashion.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2020 Tipo de documento: Article