Your browser doesn't support javascript.
loading
Unilateral vs. bilateral hamstring strength assessments: comparing reliability and inter-limb asymmetries in female soccer players.
Cuthbert, Matthew; Comfort, Paul; Ripley, Nicholas; McMahon, John J; Evans, Martin; Bishop, Chris.
Afiliação
  • Cuthbert M; Human Performance Laboratory, Directorate of Sport, Exercise, and Physiotherapy, University of Salford, Salford, Greater Manchester, UK.
  • Comfort P; Technical Directorate Division, The FA Group, St George's Park, Burton-Upon-Trent, Staffordshire, UK.
  • Ripley N; Human Performance Laboratory, Directorate of Sport, Exercise, and Physiotherapy, University of Salford, Salford, Greater Manchester, UK.
  • McMahon JJ; School of Medical and Health Sciences, Edith Cowan University, Joondalup, Australia.
  • Evans M; Institute for Sport, Physical Activity and Leisure, Carnegie School of Sport, Leeds Beckett University, Leeds, UK.
  • Bishop C; Human Performance Laboratory, Directorate of Sport, Exercise, and Physiotherapy, University of Salford, Salford, Greater Manchester, UK.
J Sports Sci ; 39(13): 1481-1488, 2021 Jul.
Article em En | MEDLINE | ID: mdl-33522427
ABSTRACT
The aims in the present study were to assess reliability for two unilateral and two bilateral field-based hamstring assessments and compare magnitude, direction and agreement of inter-limb asymmetry between tests and sessions. Twenty-nine female soccer players (age 21.1 ± 4.5 years; height 169.7 ± 5.8 cm; body mass 66.2 ± 6.4 kg) performed three repetitions per leg of unilateral isometric 30° and 90° knee flexion (KF) tasks, and three repetitions total for a bilateral 90° isometric KF and Nordic hamstring exercise. Absolute reliability of most methods were acceptable (<10%). Relative reliability within-session was fair to excellent (ICC≥0.784; lower bound 95%CI ≥0.623). Greater variability in between-session relative reliability was observed during the unilateral tests, demonstrating poor to good (ICC = 0.698-0.798; lower bound 95%CI = 0.274-0.638). Bilateral assessments demonstrated similar ranges of poor to excellent (ICC = 0.679-0.963; lower bound 95%CI = 0.231-0.790). Agreement between-session for inter-limb asymmetry identification was slight and fair in the unilateral tests, with moderate to substantial agreement demonstrated in the bilateral. Being the most reliable within- and between-sessions, demonstrating substantial agreement in asymmetry between-sessions, the NHE would be most appropriate to identify inter-limb asymmetry and assess chronic changes in hamstring strength.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Limite: Adolescent / Adult / Female / Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Limite: Adolescent / Adult / Female / Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article