Your browser doesn't support javascript.
loading
Comparison of DNA typing success in compromised blood and touch samples based on sampling swab composition.
Smith, Chastyn; Cox, Jordan O; Rhodes, Ciara; Lewis, Carolyn; Koroma, Memunatu; Hudson, Brittany C; Dawson Cruz, Tracey; Seashols-Williams, Sarah J.
Afiliação
  • Smith C; Department of Forensic Science, Virginia Commonwealth University, Richmond, VA, USA.
  • Cox JO; Department of Forensic Science, Virginia Commonwealth University, Richmond, VA, USA.
  • Rhodes C; Department of Forensic Science, Virginia Commonwealth University, Richmond, VA, USA.
  • Lewis C; Department of Forensic Science, Virginia Commonwealth University, Richmond, VA, USA.
  • Koroma M; Department of Forensic Science, Virginia Commonwealth University, Richmond, VA, USA.
  • Hudson BC; Department of Forensic Science, Virginia Commonwealth University, Richmond, VA, USA.
  • Dawson Cruz T; Department of Forensic Science, Virginia Commonwealth University, Richmond, VA, USA.
  • Seashols-Williams SJ; Department of Forensic Science, Virginia Commonwealth University, Richmond, VA, USA.
J Forensic Sci ; 66(4): 1427-1434, 2021 Jul.
Article em En | MEDLINE | ID: mdl-33624316
Sample collection at the crime scene can introduce variations in DNA recovery based upon the substrate from which a sample is collected, the material of the collection device used, or the storage conditions after collection. There are many factors during this process that can degrade the sample during drying and storage, and before DNA extraction can be performed. The purpose of this study was to evaluate and compare the performance of standard cotton swab collection with the Bode BioSafe® swab, which includes both a desiccant at the swab head and proprietary compounds to prevent degradation of the sample during sample collection and preservation. Blood and touch DNA samples were collected from porous and nonporous substrates and stored at elevated temperatures to simulate accelerated time. DNA quantification and STR profile data were used to assess the performance of the swabs. BioSafe® swab collection resulted in similar DNA yields from blood samples and significantly higher DNA yields from touch samples when compared to collection with cotton swabs. BioSafe® swabs also resulted in higher DNA integrity during long-term storage, increased STR profile success and improved retention of low-level contributor alleles.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Limite: Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Limite: Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article