Your browser doesn't support javascript.
loading
2D cine vs. 3D self-navigated free-breathing high-resolution whole heart cardiovascular magnetic resonance for aortic root measurements in congenital heart disease.
Nussbaumer, Clément; Bouchardy, Judith; Blanche, Coralie; Piccini, Davide; Pavon, Anna-Giulia; Monney, Pierre; Stuber, Matthias; Schwitter, Jürg; Rutz, Tobias.
Afiliação
  • Nussbaumer C; Service of Cardiology, Centre de Resonance Magnétique Cardiaque, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.
  • Bouchardy J; Service of Cardiology, Adult Congenital Heart Disease Unit, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.
  • Blanche C; Service of Cardiology, Centre de Resonance Magnétique Cardiaque, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.
  • Piccini D; Department of Radiology, University Hospital and University of Lausanne, Lausanne, Switzerland.
  • Pavon AG; Advanced Clinical Imaging Technology, Siemens Healthcare AG, Lausanne, Switzerland.
  • Monney P; Service of Cardiology, Centre de Resonance Magnétique Cardiaque, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.
  • Stuber M; Service of Cardiology, Centre de Resonance Magnétique Cardiaque, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.
  • Schwitter J; Department of Radiology, University Hospital and University of Lausanne, Lausanne, Switzerland.
  • Rutz T; Service of Cardiology, Centre de Resonance Magnétique Cardiaque, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.
J Cardiovasc Magn Reson ; 23(1): 65, 2021 05 27.
Article em En | MEDLINE | ID: mdl-34039356
BACKGROUND: Cardiovascular magnetic resonance (CMR) is considered the method of choice for evaluation of aortic root dilatation in congenital heart disease. Usually, a cross-sectional 2D cine stack is acquired perpendicular to the vessel's axis. However, this method requires a considerable patient collaboration and precise planning of image planes. The present study compares a recently introduced 3D self-navigated free-breathing high-resolution whole heart CMR sequence (3D self nav) allowing a multiplanar retrospective reconstruction of the aortic root as an alternative to the 2D cine technique for determination of aortic root diameters. METHODS: A total of 6 cusp-commissure (CuCo) and cusp-cusp (CuCu) enddiastolic diameters were measured by two observers on 2D cine and 3D self nav cross-sectional planes of the aortic root acquired on a 1.5 T CMR scanner. Asymmetry of the aortic root was evaluated by the ratio of the minimal to the maximum 3D self nav CuCu diameter. CuCu diameters were compared to standard transthoracic echocardiographic (TTE) aortic root diameters. RESULTS: Sixty-five exams in 58 patients (32 ± 15 years) were included. Typically, 2D cine and 3D self nav spatial resolution was 1.1-1.52 × 4.5-7 mm and 0.9-1.153 mm, respectively. 3D self nav yielded larger maximum diameters than 2D cine: CuCo 37.2 ± 6.4 vs. 36.2 ± 7.0 mm (p = 0.006), CuCu 39.7 ± 6.3 vs. 38.5 ± 6.5 mm (p < 0.001). CuCu diameters were significantly larger (2.3-3.9 mm, p < 0.001) than CuCo and TTE diameters on both 2D cine and 3D self nav. Intra- and interobserver variabilities were excellent for both techniques with bias of -0.5 to 1.0 mm. Intra-observer variability of the more experienced observer was better for 3D self nav (F-test p < 0.05). Aortic root asymmetry was more pronounced in patients with bicuspid aortic valve (BAV: 0.73 (interquartile (IQ) 0.69; 0.78) vs. 0.93 (IQ 0.9; 0.96), p < 0.001), which was associated to a larger difference of maximum CuCu to TTE diameters: 5.5 ± 3.3 vs. 3.3 ± 3.8 mm, p = 0.033. CONCLUSION: Both, the 3D self nav and 2D cine CMR techniques allow reliable determination of aortic root diameters. However, we propose to privilege the 3D self nav technique and measurement of CuCu diameters to avoid underestimation of the maximum diameter, particularly in patients with asymmetric aortic roots and/or BAV.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Observational_studies / Prevalence_studies / Prognostic_studies / Risk_factors_studies Limite: Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Observational_studies / Prevalence_studies / Prognostic_studies / Risk_factors_studies Limite: Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article