Your browser doesn't support javascript.
loading
Lung-to-finger circulation time can be measured stably with high reproducibility by simple breath holding method in cardiac patients.
Tobushi, Tomoyuki; Kasai, Takatoshi; Hirose, Masayuki; Sakai, Kazuhiro; Akamatsu, Manabu; Ohsawa, Chizuru; Yoshioka, Yasuko; Suda, Shoko; Shiroshita, Nanako; Nakamura, Ryo; Kadokami, Toshiaki; Tohyama, Takeshi; Funakoshi, Kouta; Hosokawa, Kazuya; Ando, Shin-Ichi.
Afiliação
  • Tobushi T; Department of Cardiovascular Medicine, Saiseikai Futsukaichi Hospital, Chikushino, Japan.
  • Kasai T; Department of Cardiovascular Medicine, Juntendo University Graduate School of Medicine, Tokyo, Japan.
  • Hirose M; Cardiovascular Respiratory Sleep Medicine, Juntendo University Graduate School of Medicine, Tokyo, Japan.
  • Sakai K; Center for Clinical and Translational Research, Kyushu University Hospital, Fukuoka, Japan.
  • Akamatsu M; Imaging Device Development, Fuji Xerox Co., Ltd., Kanagawa, Japan.
  • Ohsawa C; Imaging Device Development, Fuji Xerox Co., Ltd., Kanagawa, Japan.
  • Yoshioka Y; Imaging Device Development, Fuji Xerox Co., Ltd., Kanagawa, Japan.
  • Suda S; Sleep Apnea Center, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan.
  • Shiroshita N; Department of Cardiovascular Medicine, Juntendo University Graduate School of Medicine, Tokyo, Japan.
  • Nakamura R; Cardiovascular Respiratory Sleep Medicine, Juntendo University Graduate School of Medicine, Tokyo, Japan.
  • Kadokami T; Department of Cardiovascular Medicine, Saiseikai Futsukaichi Hospital, Chikushino, Japan.
  • Tohyama T; Department of Cardiovascular Medicine, Saiseikai Futsukaichi Hospital, Chikushino, Japan.
  • Funakoshi K; Center for Clinical and Translational Research, Kyushu University Hospital, Fukuoka, Japan.
  • Hosokawa K; Center for Clinical and Translational Research, Kyushu University Hospital, Fukuoka, Japan.
  • Ando SI; Department of Cardiovascular Medicine, Kyushu University Hospital, Fukuoka, Japan.
Sci Rep ; 11(1): 15913, 2021 08 05.
Article em En | MEDLINE | ID: mdl-34354137
Lung to finger circulation time (LFCT) has been used to estimate cardiac function. We developed a new LFCT measurement device using a laser sensor at fingertip. We measured LFCT by measuring time from re-breathing after 20 s of breath hold to the nadir of the difference of transmitted red light and infrared light, which corresponds to percutaneous oxygen saturation. Fifty patients with heart failure were enrolled. The intrasubject stability of the measurement was assessed by the intraclass correlation coefficient (ICC). The ICC calculated from 44 cases was 0.85 (95% confidence interval: 0.77-0.91), which means to have "Excellent reliability." By measuring twice, at least one clear LFCT value was obtained in 89.1% of patients and the overall measurability was 95.7%. We conducted all LFCT measurements safely. High ICCs were obtained even after dividing patients according to age, cardiac index (CI); 0.85 and 0.84 (≥ 75 or < 75 years group, respectively), 0.81 and 0.84 (N = 26, ≥ or < 2.2 L/min/M2). These results show that our new method to measure LFCT is highly stable and feasible for any type of heart failure patients.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2021 Tipo de documento: Article