Your browser doesn't support javascript.
loading
Corneal Biomechanics Assessment with Ultra High Speed Scheimpflug Camera in Primary Open Angle Glaucoma Compared with Healthy Subjects: A meta-analysis of the Literature.
Catania, Fiammetta; Morenghi, Emanuela; Rosetta, Pietro; Paolo, Vinciguerra; Vinciguerra, Riccardo.
Afiliação
  • Catania F; Department of Biomedical Sciences, Humanitas University, Milan, Italy.
  • Morenghi E; Humanitas Clinical and Research Center, IRCCS, Rozzano, Italy.
  • Rosetta P; Department of Biomedical Sciences, Humanitas University, Milan, Italy.
  • Paolo V; Humanitas Clinical and Research Center, IRCCS, Rozzano, Italy.
  • Vinciguerra R; Humanitas San Pio X, Milano, Italy.
Curr Eye Res ; 48(2): 161-171, 2023 02.
Article em En | MEDLINE | ID: mdl-35385343
PURPOSE: The aim of this meta-analysis of the literature is to provide a comprehensive analysis of the differences in Corvis ST dynamic corneal response (DCR) parameters between primary open-angle glaucoma (POAG) patients and healthy controls. METHODS: A quantitative meta-analysis was conducted on articles published before September 10, 2021 identified by searching PubMed, EMBASE, and Web of Science. Prospective studies comparing DCR Corvis ST parameter in high tension POAG and healthy controls were included. The random-effects model was conducted. Assessment of heterogeneity was based on the calculation of I2. Funnel plots evaluation and meta-regression were performed in case of detection of high heterogeneity. RESULTS: The selection process resulted in the inclusion of six articles. Pooled analysis revealed that POAG corneas respond to mechanical stimulus with a smaller concavity, showing lower deformation amplitude (DA) (CI95% -0.991 to -0.578; p < .001; I2 = 0%), higher highest concavity radius (HCR; confidence interval [CI]95% -0.01 to 0.34; p = .058; I2 = 6.7%), and lower peak distance (PD; CI95% -1.06 to -0.024; p = .040; I2 = 86.5%). They also show a slower loading phase, with lower highest concavity time (HCT; CI95% -0.39 to -0.02; p = .029; I2 = 3.3%) and lower applanation velocity-1 (CI95% -0.641 to -0.127; p = .003; I2 = 34.6%), and a faster restoration to the original form, shown by lower applanation time-2 (CI95% -1.123 to -0.544; p = .001; I2 = 44.8%) compared to healthy subjects. CONCLUSIONS: High tension POAG patients are characterized by stiffer corneas compared to healthy controls. These differences are valid also after removing the effect of age, corneal thickness, and intraocular pressure (IOP).
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Observational_studies / Systematic_reviews Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Observational_studies / Systematic_reviews Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article