Your browser doesn't support javascript.
loading
Thermal Degradation Kinetics and pH-Rate Profile of Verbascoside and Stability Improvement by Solid Lipid Nanoparticles.
Wisuitiprot, Vanuchawan; Ingkaninan, Kornkanok; Chakkavittumrong, Panlop; Wisuitiprot, Wudtichai; Wongwad, Eakkaluk; Waranuch, Neti.
Afiliação
  • Wisuitiprot V; Department of Pharmaceutical Technology, Faculty of Pharmaceutical Sciences, and Center of Excellence for Innovation in Chemistry, Naresuan University, Phitsanulok 65000, Thailand.
  • Ingkaninan K; Department of Pharmaceutical Chemistry and Pharmacognosy, Faculty of Pharmaceutical Sciences, Naresuan University, Phitsanulok 65000, Thailand.
  • Chakkavittumrong P; Division of Dermatology, Department of Medicine, Faculty of Medicine, Thammasat University, Pathumthani 12121, Thailand.
  • Wisuitiprot W; Sirindhorn College of Public Health Phitsanulok, Faculty of Public Health and Allied Health Sciences, Praboromarajchanok Institute, Ministry of Public Health, Phitsanulok 65130, Thailand.
  • Wongwad E; Department of Pharmaceutical Chemistry and Pharmacognosy, Faculty of Pharmaceutical Sciences, Naresuan University, Phitsanulok 65000, Thailand.
  • Waranuch N; Department of Cosmetic Sciences, School of Pharmaceutical Sciences, University of Phayao, Phayao 56000, Thailand.
ACS Med Chem Lett ; 13(7): 1191-1197, 2022 Jul 14.
Article em En | MEDLINE | ID: mdl-35859872
Thermal degradation of verbascoside (VB) in Acanthus ebracteatus Vahl (AE) always affects its health benefit. Here the temperature effect on VB in both AE extract and solid lipid nanoparticles (SLNs)-encapsulated AE extract was demonstrated using the Arrhenius plot. The reaction rate constants were calculated for shelf life and plotted to obtain pH-rate profiles. VB degradation was a first-order reaction. The reaction rate in a neutral to alkaline solution was faster than in an acidic solution. VB in AE extract-loaded SLNs was more stable than in uncapped AE extract. The shelf life of VB in SLNs was 153 days with activation energy (E a) of 76.16 kJ mol-1, whereas those of VB in AE extract and in AE extract solution were 75 days with E a = 78.03 kJ mol-1 and 12 days with E a = 49.24 kJ mol-1, respectively. Therefore, we anticipate that the AE extract-loaded SLNs will be beneficial for product development.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2022 Tipo de documento: Article