Your browser doesn't support javascript.
loading
Point-of-care ultrasonography to predict fluid responsiveness in children: A systematic review and meta-analysis.
Carioca, Fernando de Lima; de Souza, Fabiana Mendes; de Souza, Thalita Belato; Rubio, Aline Junqueira; Brandão, Marcelo Barciela; Nogueira, Roberto José Negrão; de Souza, Tiago Henrique.
Afiliação
  • Carioca FL; Department of Pediatrics, Clinics Hospital of the State University of Campinas (UNICAMP), Campinas, Brazil.
  • de Souza FM; Pediatric Intensive Care Unit, Department of Pediatrics, Clinics Hospital of the State University of Campinas (UNICAMP), Campinas, Brazil.
  • de Souza TB; Pediatric Intensive Care Unit, Department of Pediatrics, Clinics Hospital of the State University of Campinas (UNICAMP), Campinas, Brazil.
  • Rubio AJ; Pediatric Intensive Care Unit, Department of Pediatrics, Clinics Hospital of the State University of Campinas (UNICAMP), Campinas, Brazil.
  • Brandão MB; Pediatric Intensive Care Unit, Department of Pediatrics, Clinics Hospital of the State University of Campinas (UNICAMP), Campinas, Brazil.
  • Nogueira RJN; Pediatric Intensive Care Unit, Department of Pediatrics, Clinics Hospital of the State University of Campinas (UNICAMP), Campinas, Brazil.
  • de Souza TH; Pediatric Intensive Care Unit, Department of Pediatrics, Clinics Hospital of the State University of Campinas (UNICAMP), Campinas, Brazil.
Paediatr Anaesth ; 33(1): 24-37, 2023 01.
Article em En | MEDLINE | ID: mdl-36222022
BACKGROUND: Point-of-care ultrasonography (POCUS) is proposed as a valuable method for hemodynamic monitoring and several ultrasound-based predictors of fluid responsiveness have been studied. The main objective of this study was to assess the accuracy of these predictors in children. METHODS: PubMed, Embase, Scopus, ClinicalTrials.gov, and Cochrane Library databases were searched for relevant publications through July 2022. Pediatric studies reporting accuracy estimates of ultrasonographic predictors of fluid responsiveness were included since they had used a standard definition of fluid responsiveness and had performed an adequate fluid challenge. RESULTS: Twenty-three studies involving 1028 fluid boluses were included, and 12 predictors were identified. A positive response to fluid infusion was observed in 59.7% of cases. The vast majority of participants were mechanically ventilated (93.4%). The respiratory variation in aortic blood flow peak velocity (∆Vpeak) was the most studied predictor, followed by the respiratory variation in inferior vena cava diameter (∆IVC). The pooled sensitivity and specificity of ∆Vpeak were 0.84 (95% CI, 0.76-0.90) and 0.82 (95% CI, 0.75-0.87), respectively, and the area under the summary receiver operating characteristic curve (AUSROC) was 0.89 (95% CI, 0.86-0.92). The ∆IVC presented a pooled sensitivity and specificity of 0.79 (95% CI, 0.62-0.90) and 0.70 (95% CI, 0.51-0.84), respectively, and an AUSROC of 0.81 (95% CI, 0.78-0.85). Significant heterogeneity in accuracy estimates across studies was observed. CONCLUSIONS: POCUS has the potential to accurately predict fluid responsiveness in children. However, only ∆Vpeak was found to be a reliable predictor. There is a lack of evidence supporting the use of POCUS to guide fluid therapy in spontaneously breathing children.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies / Risk_factors_studies / Systematic_reviews Limite: Child / Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies / Risk_factors_studies / Systematic_reviews Limite: Child / Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article