Your browser doesn't support javascript.
loading
Rapid Derivatization of Phenolic and Oxime Hydroxyl with Isonicotinoyl Chloride under Aqueous Conditions and Its Application in LC-MS/MS Profiling Multiclass Steroids.
Liao, Hui-Yang; Xiao, Xuan; Peng, Rui; Le, Juan; Wang, Hai-Bo; Wang, Shao-Ting.
Afiliação
  • Liao HY; Department of Clinical Laboratory, Institute of Translational Medicine, Renmin Hospital of Wuhan University, Wuhan 430060, China.
  • Xiao X; Department of Clinical Laboratory, Institute of Translational Medicine, Renmin Hospital of Wuhan University, Wuhan 430060, China.
  • Peng R; Department of Clinical Laboratory, Institute of Translational Medicine, Renmin Hospital of Wuhan University, Wuhan 430060, China.
  • Le J; Department of Clinical Laboratory, Institute of Translational Medicine, Renmin Hospital of Wuhan University, Wuhan 430060, China.
  • Wang HB; Department of Clinical Laboratory, Institute of Translational Medicine, Renmin Hospital of Wuhan University, Wuhan 430060, China.
  • Wang ST; Department of Clinical Laboratory, Institute of Translational Medicine, Renmin Hospital of Wuhan University, Wuhan 430060, China.
Anal Chem ; 94(51): 17980-17987, 2022 12 27.
Article em En | MEDLINE | ID: mdl-36521069
Quantification of steroids possesses a crucial clinical value in early diagnosis and prognosis evaluation of various endocrine diseases. However, it is still challenging to realize feasible analysis of estrogens, androgens, progestogens, and corticoids within one single workflow. In this study, two derivatization reactions were newly designed for improvement: (1) acylation of phenolic hydroxyl on estrogens with isonicotinoyl chloride (INC) under the catalysis of 4-dimethylaminopyridine and (2) post-modification of oxime hydroxyl on hydroxylamine-pretreated ketosteroids with INC. Both reactions could conduct instantaneously at room temperature under aqueous conditions. Moreover, the resulting phenolic-INC and oxime-INC esters exhibited favorable MS responses. Through integrating these derivatization strategies with cold-induced phase separation technology, a feasible LC-MS/MS method was developed for simultaneous quantification of 15 multiclass steroids with proper sample consumption (50 µL serum), satisfying sensitivity (lower limit of quantitation at 0.01-5.00 ng/mL) and high throughput (40 min for sample-preparation). The practical applicability was tested by detecting 30 real samples from pregnant and non-pregnant women. The obtained results showed a good agreement with a previous validated methodology.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Screening_studies Limite: Female / Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Screening_studies Limite: Female / Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article