Your browser doesn't support javascript.
loading
Incidence and management of atrioventricular conduction disorders in new-onset left bundle branch block after TAVI: A prospective multicenter study.
Massoullié, Grégoire; Ploux, Sylvain; Souteyrand, Géraud; Mondoly, Pierre; Pereira, Bruno; Amabile, Nicolas; Jean, Frédéric; Irles, Didier; Mansourati, Jacques; Combaret, Nicolas; Mechulan, Alexis; Badoz, Marc; Da Costa, Antoine; Defaye, Pascal; Motreff, Pascal; Clerfond, Guillaume; Bordachar, Pierre; Eschalier, Romain.
Afiliação
  • Massoullié G; Cardiology Department, CHU Clermont-Ferrand, Clermont-Ferrand, France; Université Clermont Auvergne, CHU Clermont-Ferrand, CNRS, SIGMA Clermont, Institut Pascal, Clermont-Ferrand, France.
  • Ploux S; Hôpital Cardiologique du Haut-Lévêque, CHU Bordeaux, Université Bordeaux, IHU LIRYC, Bordeaux, France.
  • Souteyrand G; Cardiology Department, CHU Clermont-Ferrand, Clermont-Ferrand, France; Université Clermont Auvergne, CHU Clermont-Ferrand, CNRS, SIGMA Clermont, Institut Pascal, Clermont-Ferrand, France.
  • Mondoly P; Federation of Cardiology, University Hospital Rangueil, Toulouse cedex, France.
  • Pereira B; Biostatistics Unit (Clinical Research and Innovation Direction), CHU Clermont-Ferrand, Clermont-Ferrand, France.
  • Amabile N; Institut Mutualiste Montsouris, Paris, France.
  • Jean F; Cardiology Department, CHU Clermont-Ferrand, Clermont-Ferrand, France.
  • Irles D; CH Annecy Genèvois, Pringy, France.
  • Mansourati J; Department of Cardiology, University Hospital, Brest, France.
  • Combaret N; Cardiology Department, CHU Clermont-Ferrand, Clermont-Ferrand, France; Université Clermont Auvergne, CHU Clermont-Ferrand, CNRS, SIGMA Clermont, Institut Pascal, Clermont-Ferrand, France.
  • Mechulan A; Ramsay Générale de Santé, Hôpital Privé de Clairval, Marseille, France.
  • Badoz M; Department of Cardiology, University Hospital Jean Minjoz, Besançon, France.
  • Da Costa A; North Hospital, Saint-Etienne, France.
  • Defaye P; Arrhythmia Unit, Cardiology Department, University Hospital, Grenoble, France.
  • Motreff P; Cardiology Department, CHU Clermont-Ferrand, Clermont-Ferrand, France; Université Clermont Auvergne, CHU Clermont-Ferrand, CNRS, SIGMA Clermont, Institut Pascal, Clermont-Ferrand, France.
  • Clerfond G; Cardiology Department, CHU Clermont-Ferrand, Clermont-Ferrand, France; Université Clermont Auvergne, CHU Clermont-Ferrand, CNRS, SIGMA Clermont, Institut Pascal, Clermont-Ferrand, France.
  • Bordachar P; Hôpital Cardiologique du Haut-Lévêque, CHU Bordeaux, Université Bordeaux, IHU LIRYC, Bordeaux, France.
  • Eschalier R; Cardiology Department, CHU Clermont-Ferrand, Clermont-Ferrand, France; Université Clermont Auvergne, CHU Clermont-Ferrand, CNRS, SIGMA Clermont, Institut Pascal, Clermont-Ferrand, France. Electronic address: reschalier@chu-clermontferrand.fr.
Heart Rhythm ; 20(5): 699-706, 2023 05.
Article em En | MEDLINE | ID: mdl-36646235
ABSTRACT

BACKGROUND:

New-onset left bundle branch block (LBBB) is one of the most frequent complications after transcatheter aortic valve implantation (TAVI) and is associated with delayed high degree atrioventricular (AV) block.

OBJECTIVES:

The objectives of this study were to determine the incidence of AV block in such a population and to assess the performance and safety of a risk stratification algorithm on the basis of electrophysiology study (EPS) followed by implantation of a pacemaker or implantable loop recorder (ILR).

METHODS:

This was a prospective open-label study with 12-month follow-up. From June 8, 2015, to November 8, 2018, 183 TAVI recipients (mean age 82.3 ± 5.9 years) were included at 10 centers. New-onset LBBB after TAVI persisting for >24 hours was assessed by electrophysiology study during initial hospitalization. High-risk patients (His-ventricle interval ≥70 ms) were implanted with a dual-chamber pacemaker recording AV conduction disturbance episodes. Patients at lower risk were implanted with an ILR with automatic remote monitoring.

RESULTS:

A high-grade AV conduction disorder was identified in 56 patients (30.6%) at 12 months. Four subjects were symptomatic, all in the ILR group. No complications were associated with the stratification procedure. Patients with His-ventricle interval ≥70 ms displayed more high-grade AV conduction disorders (53.2% [25 of 47] vs 22.8% [31 of 136]; P < .001). In a multivariate analysis, His-ventricle interval ≥70 ms was independently associated with the occurrence of a high-grade conduction disorder (subdistribution hazard ratio 2.4; 95% confidence interval 1.2-4.8; P = .010).

CONCLUSION:

New-onset LBBB after TAVI was associated with high rates of high-grade AV conduction disturbances. The stratification algorithm provided safe and valuable aid to management decisions and reliable guidance on pacemaker implantation.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Clinical_trials / Diagnostic_studies / Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Aged80 / Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Clinical_trials / Diagnostic_studies / Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Aged80 / Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article