Your browser doesn't support javascript.
loading
A pH-Controlled Solid Inhibitor Based on PAM Hydrogel for Steel Corrosion Protection in Wide Range pH NaCl Medium.
Yang, Qing; Lin, Bing; Tang, Junlei; Wang, Yingying; Zheng, Hongpeng; Zhang, Hailong; Nie, Zhen; Zhang, Yanna.
Afiliação
  • Yang Q; School of Chemistry and Chemical Engineering & Institute for Carbon Neutrality, Southwest Petroleum University, Chengdu 610500, China.
  • Lin B; School of Chemistry and Chemical Engineering & Institute for Carbon Neutrality, Southwest Petroleum University, Chengdu 610500, China.
  • Tang J; School of Chemistry and Chemical Engineering & Institute for Carbon Neutrality, Southwest Petroleum University, Chengdu 610500, China.
  • Wang Y; Tianfu Yongxing Laboratory, Chengdu 610217, China.
  • Zheng H; Key Laboratory of Optoelectronic Chemical Materials and Devices (Ministry of Education), Jianghan University, Wuhan 430056, China.
  • Zhang H; School of Chemistry and Chemical Engineering & Institute for Carbon Neutrality, Southwest Petroleum University, Chengdu 610500, China.
  • Nie Z; School of Chemistry and Chemical Engineering & Institute for Carbon Neutrality, Southwest Petroleum University, Chengdu 610500, China.
  • Zhang Y; Research Institute of Tianfu New Energy, Chengdu 610217, China.
Molecules ; 28(3)2023 Jan 30.
Article em En | MEDLINE | ID: mdl-36770984
To provide carbon steel a long-term corrosion protection effect in NaCl solutions with different pH values, based on poly-acrylamide (PAM) and oleate imidazoline (OIM), a solid corrosion inhibitor with the properties of pH-controlled release was synthesized. SEM, FTIR and TGA results indicated that the OIM inhibitors were successfully loaded into PAM hydrogel with a high OIM encapsulation content (39.64 wt.%). The OIM release behavior from the hydrogel structure has two stages, quick release and sustained release. The pH of solutions could affect the initial release kinetics of OIM inhibitors and the diffusion path in the hydrogel structure. Weight loss measurement of L80 steel in different pH solutions with OIM@PAM proved the inhibitor responsive release mechanism and anticorrosion performance. The inhibition efficiency of OIM@PAM can maintain over 80% after long-term immersion in a harsh corrosive environment (pH 3), which is much higher than the inhibition efficiency of OIM@PAM in a moderate corrosive solution.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article