Your browser doesn't support javascript.
loading
Biportal endoscopic extraforaminal lumbar interbody fusion using a 3D-printed porous titanium cage with large footprints: technical note and preliminary results.
You, Ki-Han; Hwang, Jae-Yeun; Hong, Seok-Ho; Kang, Min-Seok; Park, Sang-Min; Park, Hyun-Jin.
Afiliação
  • You KH; Department of Orthopedic Surgery, Spine Center, Hallym University College of Medicine, Kangnam Sacred Heart Hospital, 1, Singil-ro, Yeongdeungpo-gu, Seoul, 07441, Republic of Korea.
  • Hwang JY; Department of Orthopedic Surgery, Spine Center, Hallym University College of Medicine, Kangnam Sacred Heart Hospital, 1, Singil-ro, Yeongdeungpo-gu, Seoul, 07441, Republic of Korea.
  • Hong SH; Department of Orthopedic Surgery, Spine Center, Hallym University College of Medicine, Kangnam Sacred Heart Hospital, 1, Singil-ro, Yeongdeungpo-gu, Seoul, 07441, Republic of Korea.
  • Kang MS; Department of Orthopedic Surgery, Korea University College of Medicine, Anam Hospital, Seoul, Republic of Korea.
  • Park SM; Department of Orthopedic Surgery, Seoul National University College of Medicine, Seoul National University Bundang Hospital, Seoul, Republic of Korea.
  • Park HJ; Department of Orthopedic Surgery, Spine Center, Hallym University College of Medicine, Kangnam Sacred Heart Hospital, 1, Singil-ro, Yeongdeungpo-gu, Seoul, 07441, Republic of Korea. phjfrog@gmail.com.
Acta Neurochir (Wien) ; 165(6): 1435-1443, 2023 06.
Article em En | MEDLINE | ID: mdl-37115323
ABSTRACT

PURPOSE:

The aim of this study was to introduce biportal endoscopic extraforaminal lumbar interbody fusion (BE-EFLIF), which involves insertion of a cage through a more lateral side as compared to the conventional corridor of transforaminal lumbar interbody fusion. We described the advantages and surgical steps of 3D-printed porous titanium cage with large footprints insertion through multi-portal approach, and preliminary results of this technique.

METHODS:

This retrospective study included 12 consecutive patients who underwent BE-EFLIF for symptomatic single-level lumbar degenerative disease. Clinical outcomes, including a visual analog scale (VAS) for back and leg pain and the Oswestry disability index (ODI), were collected at preoperative months 1 and 3, and 6 months postoperatively. In addition, perioperative data and radiographic parameters were analyzed.

RESULTS:

The mean patient age, follow-up period, operation time, and volume of surgical drainage were 68.3 ± 8.4 years, 7.6 ± 2.8 months, 188.3 ± 42.4 min, 92.5 ± 49.6 mL, respectively. There were no transfusion cases. All patients showed significant improvement in VAS and ODI postoperatively, and these were maintained for 6 months after surgery (P < 0.001). The anterior and posterior disc heights significantly increased after surgery (P < 0.001), and the cage was ideally positioned in all patients. There were no incidences of early cage subsidence or other complications.

CONCLUSIONS:

BE-EFLIF using a 3D-printed porous titanium cage with large footprints is a feasible option for minimally invasive lumbar interbody fusion. This technique is expected to reduce the risk of cage subsidence and improve the fusion rate.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Observational_studies / Risk_factors_studies Limite: Aged / Humans / Middle aged Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Observational_studies / Risk_factors_studies Limite: Aged / Humans / Middle aged Idioma: En Ano de publicação: 2023 Tipo de documento: Article