Your browser doesn't support javascript.
loading
Utility of Carbon Dioxide Venography and Intraprocedural CT for Adrenal Venous Sampling in Patients with an Allergy to Iodinated Contrast Media.
Kamada, Hiroki; Seiji, Kazumasa; Oguro, Sota; Ota, Hideki; Yanagaki, Satoru; Omata, Kei; Tezuka, Yuta; Ono, Yoshikiyo; Morimoto, Ryo; Satoh, Fumitoshi; Takase, Kei.
Afiliação
  • Kamada H; Department of Diagnostic Radiology, Tohoku University Hospital, Sendai, Miyagi, Japan. Electronic address: hkamada@rad.med.tohoku.ac.jp.
  • Seiji K; Department of Diagnostic Radiology, South Miyagi Medical Center, Ohgawara, Miyagi, Japan.
  • Oguro S; Department of Diagnostic Radiology, Tohoku University Hospital, Sendai, Miyagi, Japan.
  • Ota H; Department of Diagnostic Radiology, Tohoku University Hospital, Sendai, Miyagi, Japan.
  • Yanagaki S; Department of Diagnostic Radiology, Tohoku University Hospital, Sendai, Miyagi, Japan.
  • Omata K; Division of Clinical Hypertension, Endocrinology, and Metabolism, Tohoku University Graduate School of Medicine, Sendai, Miyagi, Japan.
  • Tezuka Y; Division of Clinical Hypertension, Endocrinology, and Metabolism, Tohoku University Graduate School of Medicine, Sendai, Miyagi, Japan.
  • Ono Y; Division of Clinical Hypertension, Endocrinology, and Metabolism, Tohoku University Graduate School of Medicine, Sendai, Miyagi, Japan.
  • Morimoto R; Division of Clinical Hypertension, Endocrinology, and Metabolism, Tohoku University Graduate School of Medicine, Sendai, Miyagi, Japan.
  • Satoh F; Division of Clinical Hypertension, Endocrinology, and Metabolism, Tohoku University Graduate School of Medicine, Sendai, Miyagi, Japan.
  • Takase K; Department of Diagnostic Radiology, Tohoku University Hospital, Sendai, Miyagi, Japan.
J Vasc Interv Radiol ; 34(11): 1963-1969, 2023 11.
Article em En | MEDLINE | ID: mdl-37532095
PURPOSE: To assess the diagnostic performance of carbon dioxide (CO2) and intraprocedural unenhanced computed tomography (CT) for adrenal venous sampling (AVS) (CO2-intraprocedural unenhanced CT-AVS) in patients with primary aldosteronism (PA) and a history of iodine contrast medium allergy. MATERIALS AND METHODS: CO2-intraprocedural unenhanced CT-AVS was performed in 18 patients with iodine contrast media allergies at the authors' hospital between December 2015 and January 2021. CT and noncontrast magnetic resonance angiography were used to evaluate the preoperative adrenal vein anatomy. CO2 venography was performed to confirm adrenal vein catheterization. Additionally, intraprocedural unenhanced CT was also performed to confirm catheter position in the right adrenal gland. RESULTS: In all cases in which CO2-intraprocedural unenhanced CT-AVS was performed, the right and left adrenal veins were catheterized appropriately, leading to a localized diagnosis. Catheterization of the left adrenal vein was confirmed using CO2 venography in all cases. In 7 of the 18 cases, CO2 venography demonstrated selection of the right adrenal vein. In 15 of 18 cases, intraprocedural unenhanced CT demonstrated selection of the right adrenal vein. CONCLUSIONS: CO2-intraprocedural unenhanced CT-AVS demonstrated the same diagnostic ability for PA localization as conventional AVS with iodine contrast media. The proposed method is clinically feasible for AVS, in which iodine contrast media use is restricted.