Your browser doesn't support javascript.
loading
Development of an immunochromatographic strip test for rapid detection of a potent neutralizing anti-interferon gamma antibody in adult-onset immunodeficiency.
Yasamut, Umpa; Thongkum, Weeraya; Wongsawat, Ekkarat; Tayapiwatana, Chatchai.
Afiliação
  • Yasamut U; Division of Clinical Immunology, Department of Medical Technology, Faculty of Associated Medical Sciences, Chiang Mai University, Chiang Mai, Thailand.
  • Thongkum W; Center of Biomolecular Therapy and Diagnostic, Faculty of Associated Medical Sciences, Chiang Mai University, Chiang Mai, Thailand.
  • Wongsawat E; Center of Innovative Immunodiagnostic Development, Department of Medical Technology, Faculty of Associated Medical Sciences, Chiang Mai University, Chiang Mai, Thailand.
  • Tayapiwatana C; Division of Clinical Immunology, Department of Medical Technology, Faculty of Associated Medical Sciences, Chiang Mai University, Chiang Mai, Thailand.
Article em En | MEDLINE | ID: mdl-37578481
BACKGROUND: Adult-onset immunodeficiency (AOID) is associated with the presence of anti-interferon gamma autoantibodies (anti-IFN-γ autoAbs), which neutralizes IFN-γ signaling and leads to susceptibility to intracellular opportunistic infections. However, measuring neutralizing autoAbs is not practical for general clinical laboratories. OBJECTIVE: This study aims to develop a competitive immunochromatographic (IC) strip test for detecting autoAbs that recognize the same epitope as a potent neutralizing antibody. METHODS: The competitive IC strip test detecting autoAbs that recognize the same epitope as mouse anti-IFN-γ monoclonal antibody, clone B27 (B27 mAb) was fabricated and used to determine B27 epitope recognizing autoAb (B27 AAb) in AOID plasma. The competitive ELISA was used as a comparative method. AR patients. RESULTS: The efficacy of the IC strip test was compared with competitive ELISA and found a percent positive agreement of 91.30%, a percent negative agreement of 79.31%, and a percent overall agreement of 84.62%. CONCLUSIONS: The results from the competitive IC strip test were consistent with those from competitive ELISA, indicating that the generated IC strip could detect B27 AAb in AOID plasma.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2023 Tipo de documento: Article