Your browser doesn't support javascript.
loading
Enhanced absorbance detection system for online bacterial monitoring in digital microfluidics.
Wu, Jingya; Zhang, Maolin; Huang, Jianle; Guan, Jingxin; Hu, Chenxuan; Shi, Mude; Hu, Siyi; Wang, Shurong; Ma, Hanbin.
Afiliação
  • Wu J; Guangdong-Hong Kong-Macao Joint Laboratory for Intelligent Micro-Nano Optoelectronic Technology, School of Physics and Optoelectronic Engineering, Foshan University, Foshan 528225, P. R. China. srwang@ciomp.ac.cn.
  • Zhang M; School of Biomedical Engineering (Suzhou), Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei 230027, Anhui, P. R. China.
  • Huang J; CAS Key Laboratory of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, 215163, P. R. China. mahb@sibet.ac.cn.
  • Guan J; Guangdong ACXEL Micro & Nano Tech Co., Ltd, Guangdong Province, 528000, P. R. China.
  • Hu C; Guangdong ACXEL Micro & Nano Tech Co., Ltd, Guangdong Province, 528000, P. R. China.
  • Shi M; School of Biomedical Engineering (Suzhou), Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei 230027, Anhui, P. R. China.
  • Hu S; CAS Key Laboratory of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, 215163, P. R. China. mahb@sibet.ac.cn.
  • Wang S; Guangdong ACXEL Micro & Nano Tech Co., Ltd, Guangdong Province, 528000, P. R. China.
  • Ma H; CAS Key Laboratory of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, 215163, P. R. China. mahb@sibet.ac.cn.
Analyst ; 148(19): 4659-4667, 2023 Sep 25.
Article em En | MEDLINE | ID: mdl-37615041
ABSTRACT
We report a fully integrated digital microfluidic absorbance detection system with an enhanced sensitivity for online bacterial monitoring. Through a 100 µm gap in the chip, our optical detection system has a detection sensitivity for a BCA protein concentration of 0.1 mg mL-1. The absorbance detection limit of our system is 1.4 × 10-3 OD units, which is one order of magnitude better than that of the existing studies. The system's linear region is 0.1-7 mg mL-1, and the dynamic range is 0-25 mg mL-1. We measured the growth curves of wild-type and E. coli transformed with resistance plasmids and mixed at different ratios on chip. We sorted out the bacterial species including highly viable single cells based on the difference in absorbance data of growth curves. We explored the changes in the growth curves of E. coli under different concentrations of resistant media. In addition, we successfully screened for the optimal growth environment of the bacteria, in which the growth rate of PET30a-DH5α (in a medium with 33 µg mL-1 kanamycin resistance) was significantly higher than that of a 1 mg mL-1 resistance medium. In conclusion, the enhanced digital microfluidic absorbance detection system exhibits exceptional sensitivity, enabling precise bacterial monitoring and growth curve analysis, while also laying the foundation for DMF-based automated bioresearch platforms, thus advancing research in the life sciences.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2023 Tipo de documento: Article