Your browser doesn't support javascript.
loading
Palladium-Copper Bimetallic Aerogel as New Modifier for Highly Sensitive Determination of Bisphenol A in Real Samples.
Fang, Zehao; Wang, Junyan; Xue, Yilei; Khorasani Motlagh, Mozhgan; Noroozifar, Meissam; Kraatz, Heinz-Bernhard.
Afiliação
  • Fang Z; Department Physical and Environmental Sciences, University of Toronto Scarborough, 1265 Military Trail, Toronto, ON M1C 1A4, Canada.
  • Wang J; Department Physical and Environmental Sciences, University of Toronto Scarborough, 1265 Military Trail, Toronto, ON M1C 1A4, Canada.
  • Xue Y; Department Physical and Environmental Sciences, University of Toronto Scarborough, 1265 Military Trail, Toronto, ON M1C 1A4, Canada.
  • Khorasani Motlagh M; Department of Chemistry, University of Toronto, 280 St. George Street, Toronto, ON M5S 3H6, Canada.
  • Noroozifar M; Department Physical and Environmental Sciences, University of Toronto Scarborough, 1265 Military Trail, Toronto, ON M1C 1A4, Canada.
  • Kraatz HB; Department Physical and Environmental Sciences, University of Toronto Scarborough, 1265 Military Trail, Toronto, ON M1C 1A4, Canada.
Materials (Basel) ; 16(18)2023 Sep 05.
Article em En | MEDLINE | ID: mdl-37763359
In this study, a bimetallic palladium-copper aerogel was synthesized and used for modification of a graphite paste electrode (Pd-Cu/GPE), allowing the sensitive determination of bisphenol A (BPA). Different techniques, such as SEM, TEM, XPS, and AFM, were used for characterization of the Pd-Cu aerogel. To elucidate the properties of the Pd-Cu/GPE, the electrochemistry methods such as differential pulse voltammetry (DPV) and electrochemical impedance spectroscopy were used. DPV measurements were conducted in phosphate electrolyte and buffer solution (0.2 M PBS, pH 5) at a potential range from 0.4 to 0.9 V vs. Ag/AgCl. The DPVs peaks currents increased linearly with BPA concentrations in the 0.04-85 and 85-305 µM ranges, with a limit of detection of 20 nM. The modified electrode was successfully used in real samples to determine BPA, and the results were compared to the standard HPLC method. The results showed that the Pd-Cu/GPE had good selectivity, stability, and sensitivity for BPA determination.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2023 Tipo de documento: Article