Your browser doesn't support javascript.
loading
Retrieval of Chronically Implanted Dual-chamber Leadless Pacemakers in an Ovine Model.
Banker, Rajesh S; Rippy, Marian K; Cooper, Nicole; Neuzil, Petr; Exner, Derek V; Nair, Devi G; Booth, Daniel F; Ligon, David; Badie, Nima; Krans, Mark; Ando, Kenji; Knops, Reinoud E; Ip, James E; Doshi, Rahul N; Rashtian, Mayer; Reddy, Vivek Y.
Afiliação
  • Banker RS; Hoag Memorial Hospital, Newport Beach, CA (R.S.B.).
  • Rippy MK; Rippy Pathology Solutions, Inc, Woodbury, MN (M.K.R.).
  • Cooper N; Abbott, Sylmar, CA (N.C., D.F.B., D.L., N.B., M.K.).
  • Neuzil P; Na Homolce Hospital, Prague, Czech Republic (P.N., V.Y.R.).
  • Exner DV; Libin Cardiovascular Institute of Alberta, Calgary, Canada (D.V.E.).
  • Nair DG; St. Bernards Healthcare, Jonesboro, AR (D.G.N.).
  • Booth DF; Abbott, Sylmar, CA (N.C., D.F.B., D.L., N.B., M.K.).
  • Ligon D; Abbott, Sylmar, CA (N.C., D.F.B., D.L., N.B., M.K.).
  • Badie N; Abbott, Sylmar, CA (N.C., D.F.B., D.L., N.B., M.K.).
  • Krans M; Abbott, Sylmar, CA (N.C., D.F.B., D.L., N.B., M.K.).
  • Ando K; Kokura Memorial Hospital, Kitakyushu, Japan (K.A.).
  • Knops RE; Amsterdam UMC, the Netherlands (R.E.K.).
  • Ip JE; Weill Cornell Medical Center, NY (J.E.I.).
  • Doshi RN; Keck USC School of Medicine, Los Angeles (R.N.D.).
  • Rashtian M; Huntington Hospital, Pasadena, CA (M.R.).
  • Reddy VY; Na Homolce Hospital, Prague, Czech Republic (P.N., V.Y.R.).
Circ Arrhythm Electrophysiol ; 16(10): e012232, 2023 10.
Article em En | MEDLINE | ID: mdl-37767710
BACKGROUND: The clinical utilization of leadless pacemakers (LPs) as an alternative to traditional transvenous pacemakers is likely to increase with the advent of dual-chamber LP systems. Since device retrieval to allow LP upgrade or replacement will become an important capability, the first such dual-chamber, helix-fixation LP system (Aveir DR; Abbott, Abbott Park, IL) was specifically designed to allow catheter-based retrieval. In this study, the preclinical performance and safety of retrieving chronically implanted dual-chamber LPs was evaluated. METHODS: Atrial and ventricular LPs were implanted in the right atrial appendage and right ventricular apex of 9 healthy ovine subjects. After ≈2 years, the LPs were retrieved using a dedicated transvenous retrieval catheter (Aveir Retrieval Catheter; Abbott) by snaring, docking, and unscrewing from the myocardium. Comprehensive necropsy/histopathology studies were conducted to evaluate device- and procedure-related outcomes. RESULTS: At a median of 1.9 years postimplant (range, 1.8-2.6), all 18 of 18 (100%) LPs were retrieved from 9 ovine subjects without complications. The median retrieval procedure duration for both LPs, from first-catheter-in to last-catheter-out, was 13.3 minutes (range, 2.5-36.4). Postretrieval, all right atrial, and right ventricular implant sites demonstrated minimal tissue disruption, with intact fibrous tissue limited to the distal device body. No significant device-related trauma, perforation, pericardial effusion, right heart or tricuspid valve injury, or chronic pulmonary thromboembolism were observed at necropsy. CONCLUSIONS: This preclinical study demonstrated the safe and effective retrieval of chronically implanted, helix-fixation, dual-chamber LP systems, paving the way for clinical studies of LP retrieval.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Limite: Animals / Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Limite: Animals / Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article