Your browser doesn't support javascript.
loading
D-dimer Levels for the exclusion of pulmonary embolism: making sense of international guideline recommendations.
Fan, Bingwen Eugene; Lippi, Giuseppe; Favaloro, Emmanuel J.
Afiliação
  • Fan BE; Department of Haematology, Tan Tock Seng Hospital, Singapore; Department of Laboratory Medicine, Khoo Teck Puat Hospital, Singapore; Lee Kong Chian School of Medicine, Singapore; Yong Loo Lin School of Medicine, Singapore. Electronic address: Bingwen_Eugene_Fan@ttsh.com.sg.
  • Lippi G; Section of Clinical Biochemistry, University of Verona, Verona, Italy.
  • Favaloro EJ; Department of Haematology, Institute of Clinical Pathology and Medical Research, Sydney Centres for Thrombosis and Haemostasis, New South Wales Health Pathology, Westmead Hospital, Westmead, New South Wales, Australia; School of Dentistry and Medical Sciences, Faculty of Science and Health, Charles Sturt University, Wagga Wagga, Australia; School of Medical Sciences, Faculty of Medicine and Health, University of Sydney, Westmead Hospital, Westmead, New South Wales, Australia. Electronic address:
J Thromb Haemost ; 22(3): 604-608, 2024 Mar.
Article em En | MEDLINE | ID: mdl-38135252
ABSTRACT
Several international guidelines provide recommendations around the use of D-dimer testing for exclusion of pulmonary embolism, including the appropriate D-dimer threshold (or cutoff), but there is no consensus among them. We briefly discuss guideline variation, performance characteristics, and limitations of commercially available D-dimer assays in this setting, referencing the Clinical and Laboratory Standards Institute guidelines that recommend immunoassays with high sensitivity (≥97%) and negative predictive value (≥98%). While age-adjusted D-dimer and pretest-adjusted D-dimer are considered a safe strategy across predefined patient subgroups, clinicians need to recognize the different performance characteristics of D-dimer assays to enable safe clinical decisions for their patients. Importantly, D-dimer values must be correlated not only to clinical findings but also interpreted within the context of the accuracy and precision of the specific testing modality, adhering to manufacturer specifications that are approved by regulatory authorities.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Limite: Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Limite: Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article